Contact Us

LTC7103IUHE#TRPBF

Brand: Analog Devices
Analog Devices LTC7103IUHE#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC7103IUHE#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC7103IUHE#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC7103IUHE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC7103IUHE#TRPBF: 105 V, 2.3 A buck regulator, I grade

What this order code is

LTC7103IUHE#TRPBF is the same 105 V synchronous step-down regulator in the 5 mm by 6 mm QFN and tape and reel, with the I temperature letter. Input is 4.4 V to 105 V with a 110 V absolute maximum, output is 1 V to the input at up to 2.3 A, and the switching frequency is programmable from 200 kHz to 2 MHz with a phase lock loop.

The I letter is what puts this part on equipment that has to run outside a bench environment: 48 V and 96 V installations, outdoor cabinets, and military or avionics supplies where the commercial window is not enough. The electrical table and the limits on on time, current and emissions are the family ones.

Parameters as published

ItemValue
Input voltage range4.4 V to 105 V, 110 V absolute maximum
Output current2.3 A
Output voltage range1 V to V in, or eight fixed settings 1.2 V to 15 V
Switching frequency200 kHz to 2 MHz, programmable
Minimum on time40 ns
Quiescent current2 uA when regulating 48 V in to 3.3 V out
Efficiency81.5 percent at 100 V in, 5 V out
EmissionsCISPR 25 compliant
Current limitbrick wall, programmed without an external shunt
Bias supplyEXTV CC LDO from an output of 3.3 V to 40 V
Pass through100 percent maximum duty cycle
Body5 mm by 6 mm QFN
GradeI, limits in the ordering table

Numbers that decide the application

At 100 V in and 5 V out the part publishes 81.5 percent efficiency at 2.3 A. That is 11.5 W delivered, 14.11 W taken in, 0.14 A of input current and 2.61 W of loss in a 30 square millimetre body, which is 8.7 W per square centimetre. The same output from 12 V loses 0.80 W at 93.5 percent, so the loss at the top of the input range is three times the loss at the bottom, and the thermal margin has to be checked at 100 V rather than at 48 V.

The 40 ns minimum on time sets a frequency ceiling that depends on the ratio. At 105 V to 5 V the duty is 4.76 percent and the ceiling is 1.19 MHz; at 105 V to 12 V the duty is 11.4 percent and the ceiling is 2.2 MHz, so 2 MHz is available; at 48 V to 3.3 V the duty is 6.9 percent and the ceiling is 1.7 MHz. A single switching frequency across a family of rails is therefore usually set by the widest ratio, not by the smallest inductor.

Pass through at 100 percent duty is the dropout answer. When the input falls to the output setpoint the converter stops switching and the pass element is held on, so a 5 V rail from a 5.5 V input follows the input down instead of dropping out, which is what a battery or a brown out test actually needs.

Quiescent current of 2 uA at 48 V is 96 uW and 17.5 mAh over a year, and the EXTV CC pin can take the bias from a 3.3 V to 40 V output, which moves the gate drive loss off the input and into the output where it is already paid for.

Where it fits and where it does not

It fits an outdoor 48 V installation, a 96 V battery system, an avionics or military 28 V to 5 V rail over a wide ambient, an automotive input behind a load dump clamp, and any line that needs the wider grade letter with a single stage conversion. It does not fit a load above 2.3 A, an input above 110 V including transients, a 2 MHz frequency at a 20 to 1 ratio, or a rail below 1 V.

Supply and second source questions

The grade letter is the first field to check here, because the same part is stocked in two letters and only one meets a wide ambient qualification. The minimum on time is the second, because it is the specification that a substitute most often misses while matching the voltage and current. Regulators around these rails are compared on the power management cross reference page.

Sourcing notes and next step

We quote the IUHE code with the QFN body, the I grade and tape and reel stated, and we will not offer the E grade against it without saying so. Send the line items and the required date through the BOM shortage recovery page. The analog range is on the analog and mixed signal IC page.

LTC7103IUHE#TRPBF at 48 V in: a 25 percent duty cycle, a 15 uH inductor and 5 percent of margin under a surge

A 105 V regulator in a 48 V telecom or industrial rail is bought for its input rating, and the input rating only matters on the worst day. The arithmetic that decides whether the part survives that day is the surge margin against the absolute maximum, and the arithmetic that decides whether it works on a normal day is the duty cycle at the switching frequency. This block does both for a 48 V to 12 V, 2.3 A rail, then looks at where the loss sits.

Five percent of margin is not a lot on a 48 V rail

The part is rated to 105 V. A 48 V nominal rail with a 100 V surge leaves 5 volts, which is 5 percent, and that assumes the surge is clamped where the specification says. A rail that is specified to survive an unclamped inductive kick, or a 60 V nominal battery system that charges to 72 V and rings, needs the margin checked against the measured waveform rather than the nominal. The other side of the same decision is the minimum input: the part has to start at the lowest battery voltage the product sees, and the current limit has to be set against that current rather than the nominal one.

A 25 percent duty cycle is a comfortable place to be

At 48 V in and 12 V out the duty cycle is 0.25, so at 1 MHz the on time is 250 ns, which is far above any minimum on time limit and far below the cycle. That is the easy case for a high input voltage part: the difficulty appears at 100 V in and 5 V out, where the duty cycle is 5 percent and the on time is 50 ns at 1 MHz. A 12 V output at 48 V in is not that case, which is why this combination is the one most products use.

Fifteen microhenries and 3 W of loss

For a 30 percent ripple on 2.3 A, which is 0.69 A, the arithmetic at 1 MHz gives 13 uH and the standard value is 15 uH, which brings the ripple to 0.6 A. At 2.3 A and 12 V the output is 27.6 W, and at 90 percent efficiency the loss is 3.07 W, which has to leave a package with an exposed pad. Most of that loss is conduction in the switches and the inductor's series resistance, so the inductor's resistance and the input capacitor's ripple current rating are the two components that decide whether the 90 percent is reached in the build.

ItemFigureWhat it decides
48 V to 12 VDuty 0.25, on time 250 ns at 1 MHzComfortable against any on time floor
105 V rating at a 100 V surge5 percent marginClamp specification on the input
15 uH at 1 MHz0.6 A of rippleOutput capacitor ripple current
27.6 W out at 90 percent3.07 W of lossPad, copper and airflow

Input ratings and duty cycle limits across the family are compared on power management cross reference, the grade and package differences between order codes are on how to verify a drop in replacement, and the inductors and capacitors around the converter are on one stop BOM sourcing.

Request Quote — In Stock, 100% New & Original, Full Warranty