LT8611IUDD#TRPBF
Product Specifications
LT8611IUDD#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT8611IUDD#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LT8611IUDD#TRPBF: the current loop with a full minus 40 C guarantee
The LT8611IUDD#TRPBF is the I grade of the 2.5 A, 42 V step-down regulator with the rail-to-rail current sense amplifier, in the 24-lead 3 mm by 5 mm QFN. It is the same converter as the E grade with a guarantee over the full minus 40 C to 125 C junction range instead of a 0 C to 125 C guarantee extended by characterisation. For a charger or an LED supply that has to start cold and hold its current at cold, that difference is the whole reason to pay for the I letter.
Why a current loop is harder to guarantee than a voltage loop
| Grade on this code | I, guaranteed minus 40 C to 125 C junction |
| Input range | 3.4 V to 42 V |
| Output current | 2.5 A |
| Current sense | rail-to-rail amplifier, monitor and control pins |
| Minimum on time | 50 ns |
| Frequency | 200 kHz to 2.2 MHz, synchronisable |
| Quiescent current | 2.5 uA in burst mode |
| Dropout | 200 mV at 1 A |
| Power good | plus or minus 9 percent of the set output |
The offset of the sense amplifier is the accuracy of the current
A voltage loop is only as good as its reference, and a current loop is only as good as the offset of the amplifier that measures the shunt. On a 50 mOhm shunt, 1 A of load current is 50 mV, so every millivolt of amplifier offset is 20 mA of current error, and 2 percent of the reading at 1 A. At 100 mA the same 1 mV is 20 percent of the reading. The loop is therefore accurate at the top of its range and increasingly approximate at the bottom, which is exactly where a battery charger spends the end of its cycle.
The practical response is to size the shunt for the current the loop must control, not for the maximum the switch can deliver, and to accept that a 2.5 A part limited to 200 mA needs a larger shunt than the same part at 2 A. A 250 mOhm shunt gives 50 mV at 200 mA, which restores the accuracy at the cost of 10 mW at that current, and the same resistor would dissipate 1.56 W at 2.5 A, which is why a charger that must cover both ends uses a range switch or a two stage sense.
Cold start, low temperature and the current limit
At minus 40 C the reference and the amplifier drift, the shunt itself moves with its temperature coefficient, and the output capacitor of the supply typically loses capacitance if it is a ceramic with a high dielectric constant. The I grade guarantees the amplifier and the reference over the range, so the loop behaviour is specified; the shunt and the capacitor are the user's parts and have to be checked separately. A metal strip shunt at 50 ppm per degree moves 0.375 percent over the 75 degree span from 25 C to minus 40 C, which is small next to the amplifier offset but not zero.
Cold start also changes the load. A battery at minus 40 C accepts very little charge current, and a charger that holds its current set point will simply sit at the compliance voltage with no current flowing. The loop does not care, but the system that reads the monitor pin has to know that a low current at cold is normal rather than a fault.
Two questions buyers ask
Is the I grade needed for an indoor product? No, and it is usually wasted there. A cabinet that never goes below 0 C is covered by the E grade, and the money is better spent on the shunt accuracy. The I grade earns its place in outdoor equipment, vehicle-adjacent products and anything that is stored unheated and started in winter.
Does the grade change the frequency or the current rating? No. The 50 ns minimum on time, the 2.2 MHz ceiling, the 2.5 A output and the 42 V input are the same on both grades. What changes is the guarantee behind the specifications across temperature, and the fact that the two codes are separate order lines with separate availability.
Sourcing notes and next step
Send the full code, the shunt value, the current and voltage set points and the ambient range the product actually sees, and the quote is built on the grade that survives it. Our BOM shortage page covers the substitution rules between grades, the defense grade components page covers the documentation a high reliability programme asks for, and the analog and mixed signal category lists the rest of the family.
LT8611IUDD#TRPBF: 4.7 uH, 1 MHz, and the 54 ns of on time the 2.2 MHz setting leaves at 42 V in
Two settings on this regulator decide whether a board works across its whole input range: the switching frequency and the inductor. The frequency is usually chosen to keep the inductor small and the output ripple out of a sensitive band, and the inductor is then chosen for a ripple target. The catch is the minimum on time, which turns the highest input voltage into the setting that is actually illegal, not the lowest. This block runs the same 5 V output from 12 V and from 42 V and shows where the ceiling appears.
Duty cycle times frequency is the on time, and it has a floor
At 12 V in and 5 V out the duty cycle is 0.4167. At 1 MHz that is 417 ns of on time, at 2.2 MHz it is 189 ns, and both are far above the 50 ns floor. At 42 V in the duty cycle falls to 0.119, so 2.2 MHz asks for 54 ns, which is four nanoseconds of margin over the floor and no margin at all once the part is at temperature and the gate driver is slow. The practical rule is that the 2.2 MHz setting belongs to a 12 V rail, and a 48 V product that wants 2.2 MHz has to accept pulse skipping at the top of its input range. At 1 MHz the same 42 V case asks for 119 ns, which is comfortable.
The inductor sets the ripple, and its resistance sets the loss
For a 30 percent ripple target on a 2.5 A part, which is 0.75 A, the arithmetic at 1 MHz gives 3.9 uH and the nearest standard value is 4.7 uH, which brings the ripple down to 0.62 A. At 2.2 MHz the same target needs 1.77 uH, and 2.2 uH is the standard part. The inductor's series resistance is then the second largest loss in the converter: 20 mOhm at 2.5 A is 0.125 W, which is nine percent of the 1.39 W total that a 90 percent efficient 12.5 W output implies. Halving the resistance is worth about 60 mW, and that is usually cheaper than a larger package.
Where 1.4 W of loss ends up in a 3 by 5 mm body
At 2.5 A and 5 V out the converter delivers 12.5 W. At 90 percent efficiency it loses 1.39 W, and a 3 by 5 DFN on four layers runs near 40 C per watt, so the junction sits about 56 C above the board. A 70 C board therefore puts the junction at 126 C, above the 125 C limit, and the fix is either a lower input voltage, a lower current, or more copper under the pad. That is also the reason the current limit trim matters: a converter that limits at 3 A instead of 2.5 A has already been told it may run at a dissipation the package cannot take.
| Input | Duty | On time at 1 MHz | On time at 2.2 MHz | Verdict at 2.2 MHz |
|---|---|---|---|---|
| 12 V | 0.417 | 417 ns | 189 ns | Comfortable |
| 24 V | 0.208 | 208 ns | 95 ns | Workable |
| 42 V | 0.119 | 119 ns | 54 ns | 4 ns over a 50 ns floor |
The 50 ns floor and the frequency ceiling are compared across the family on power management cross reference, grade and package differences between order codes are on how to verify a drop in replacement, and the wider bill around the converter is covered by one stop BOM sourcing.
Request Quote — In Stock, 100% New & Original, Full Warranty