LT3796EFE#TRPBF
Product Specifications
LT3796EFE#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3796EFE#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3796EFE: Two Current Sense Amplifiers on One 100 V Controller
The LT3796 is not a single loop controller with a dimming input. It carries a programmable threshold current sense amplifier across ISP and ISN, a second high side amplifier across CSP and CSN whose gain is set by two external resistors, a constant voltage loop on FB1 and FB2, and a current monitor output. On a 100 V process that combination is what allows one part to drive a string, measure a second rail and report both, which is more than most LED drivers attempt. The package is the 28-lead FE at 30 C/W, and the sense thresholds are the numbers that size the board.
Published values
| Parameter | Value |
|---|---|
| Input voltage range | 6 V to 100 V, 100 V absolute maximum on VIN and VS |
| Full scale sense threshold | 243 mV minimum, 250 mV typical, 257 mV maximum |
| Overcurrent protection threshold | 360 to 390 mV, 375 mV typical, 1.5 times full scale |
| Current monitor output | 1 V at a 250 mV sense voltage, a gain of 4 |
| Second amplifier common mode | 0 V to 100 V, supply range 3 V to 100 V |
| Second amplifier offset | Plus or minus 3 mV |
| Feedback regulation voltage | 1.230 to 1.270 V on FB1 and FB2 |
| C/10 comparator threshold | 25 mV, 10 percent of full scale |
| Minimum on and off time | 210 ns and 190 ns |
| Switching frequency | 100 kHz to 1 MHz, 400 kHz at RT equal 19.6 k |
| Quiescent current | 2.5 mA typical, 3 mA maximum |
| Package and thermal | 28-lead TSEXP, 30 C/W junction to ambient, 10 C/W junction to case |
The second amplifier is where the extra money goes
The ISP and ISN pins measure the string current against a threshold set by CTRL, with 250 mV as full scale and 25 mV as the one tenth point. The CSP and CSN pins measure a different node, and their gain is set by two resistors, so a 100 mV full scale sense can be turned into a 1 V signal without an external amplifier. The offset of that second amplifier is plus or minus 3 mV, which is 1.2 percent of a 250 mV sense and 3 percent of a 100 mV sense, so the smaller the sense voltage the larger the share of the error the amplifier owns.
That second channel is what makes the part useful in a system that has to limit input current as well as output current, or that has to drive two strings from one inductor. The current monitor output gives 1 V at 250 mV, a gain of four, so a converter reading that pin sees 4 V at full scale and does not need a divider on a high side node.
Timing at 1 MHz leaves 21 percent of the period
The minimum on time of 210 ns and the minimum off time of 190 ns together consume 400 ns of a 1 us period, so at 1 MHz the duty cycle is bounded between 21 and 81 percent. At 400 kHz the same two numbers consume 16 percent of the 2.5 us period and the bounds relax to 8.4 percent at the low end. A 100 V to 12 V string is an 12 percent duty cycle, which is comfortable at 400 kHz and inside the corner at 1 MHz only because 210 ns is just under the 120 ns the ratio asks for at the high end of the input range.
This is the arithmetic that decides the switching frequency for a wide input converter. The ratio 100 V to 12 V is 8.3 to 1, so any frequency where 210 ns exceeds the required on time cannot regulate, and that frequency is 1.25 MHz. The 1 MHz maximum is therefore not an arbitrary catalogue number; it is the point where a 100 V input can still reach a 12 V output.
Thermal and the two shunts
At 100 V the controller draws 3 mA, which is 300 mW and a 9 C rise at 30 C/W. Two 250 mV shunts at 1 A each dissipate 0.5 W in total, and at 2 A each they dissipate 1 W, which is more than the controller and located next to it. A dual string board at 1 A per string spends 250 mW per shunt in the return path and 9 C of controller rise, which is why the exposed pad has to be a real ground plane rather than a thermal orphan.
The C/10 threshold of 25 mV is 10 percent of full scale, so a 1 A string reports taper at 100 mA. The open LED detection sits 50 to 70 mV below the 1.25 V feedback point, about 5 percent, and the overvoltage threshold sits 35 to 60 mV above it, so the two flags bracket the regulation point more tightly than the 100 V output range would suggest.
Two pages worth reading before a purchase order goes out are the power management cross reference and the ADI second source page; the first lists what else fits the socket, the second is the test sequence for a drop in, and BOM shortage recovery covers the case where the shortage is already on the line.
Two questions buyers ask
Can both strings share one inductor? Yes, that is the topology the second sense channel is for, but the two loops then act on the same inductor current, so the lower setpoint wins and the second string only receives what the first does not use. Independent strings need independent inductors or a switching arrangement that time shares them.
Is the 375 mV overcurrent threshold a cycle by cycle limit? It is a separate comparator at 1.5 times full scale, and it is there to catch a shorted string rather than to regulate. The 250 mV loop is the normal operating limit.