LT3756EMSE-2#TRPBF
Product Specifications
LT3756EMSE-2#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LT3756EMSE-2#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LT3756EMSE-2#TRPBF: The 100 V Version, 86.7 Percent Duty and a 133 ns Off Time
The LT3756 is the 100 V member of the same constant current controller family as the LT3755: 6 V to 100 V input, output up to 100 V, 100 mV high side sense, and the same boost, buck, buck boost, SEPIC and flyback coverage from one external low side MOSFET. The -2 suffix is the improved open LED status pin, which matters when the host reads the fault line rather than just tolerating it. The reason to pay for the 100 V part is a string that lives above 75 V, and that string immediately makes the duty cycle the central problem of the build.
Published values
| Parameter | Value |
|---|---|
| Input range | 6 V to 100 V |
| Output ceiling | 100 V |
| Current sense | 100 mV, high side |
| Switching frequency | 100 kHz to 1 MHz |
| PWM dimming | Up to 3000 to 1 |
| Gate supply | Internal 7.15 V for the low side MOSFET |
| Status pin | Improved open LED indication on the -2 |
| Shutdown current | Under 1 uA |
| Package | 16 lead MSOP or 3 x 3 mm QFN |
| Qualification | AEC-Q100 stated for the family |
A 90 V string at 350 mA is 31.5 W, and the input current is 2.85 A
Twenty six white LEDs at 3.4 V is 88 V, close enough to a 90 V string, and at 350 mA that is 31.5 W. From a 12 V input at 92 percent efficiency the converter draws 2.853 A, which sets the inductor saturation, the MOSFET current rating and the input capacitor ripple current all at once. That is the real cost of stepping up from 12 V to 90 V: the input side carries seven and a half times the output current, and the inductor is on the input side of a boost, so it carries the full 2.85 A plus ripple.
At 86.7 percent duty the off time is the whole problem
From 12 V to a 90 V string the boost duty cycle is 86.7 percent, which at 1 MHz leaves 133 ns of off time. Drop the input to 6 V, the bottom of the range, and the duty becomes 93.3 percent with 67 ns of off time at 1 MHz. In 67 ns the MOSFET has to turn off, the diode has to take over, and the leakage inductance spike has to settle before the current sample can be trusted for the next cycle. Running the oscillator at 200 kHz turns the same 93.3 percent into 335 ns, which is a comfortable window, and the price is a larger inductor and a little more ripple. Anyone who chooses 1 MHz for board area on a 6 V to 90 V converter is choosing a switching loss and a settling problem that no board work can repair.
The 100 mV sense at 350 mA is a 0.286 ohm resistor burning 35 mW, so the sense element is not the loss driver here; the 2.85 A input current is. Where a 90 V string meets a 12 V backplane, the practical answer is sometimes two 45 V strings in parallel from two controllers, and the cross reference for that comparison sits in the power management cross reference. Vendor specific coverage is in the ADI second source page, and a build that has to keep the same controller while the rest of the BOM moves is a drop in replacement check.
Two questions buyers ask
What does the -2 status pin change? The open LED indication on the -2 reports differently from the base part, so firmware that treats the status pin as a simple flag needs the suffix matched. On a build where the fault line drives a host interrupt, the difference is visible in the field, not on the bench.
Does the 100 V rating allow a 100 V string? No. The 100 V is a ceiling with margin, and a string that sits at 100 V at 25 C sits above it when cold, because LED forward voltage rises as temperature falls. The working number is the string voltage at the coldest operating point plus the sense and wiring drop, and it should land 15 to 20 percent below 100 V.