Contact Us

ADM1278-2ACPZ-RL

Brand: Analog Devices
Analog Devices ADM1278-2ACPZ-RL is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADM1278-2ACPZ-RL — Analog & Mixed-Signal ICs | Superb Automation

ADM1278-2ACPZ-RL

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADM1278-2ACPZ-RL from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

ADM1278-2 hot swap controller: 320 nanoseconds to short circuit and a 12-bit monitor

The ADM1278 is a hot swap controller with an integrated 12-bit analog to digital converter that reads current, voltage, power and temperature back over a serial bus, and it responds to a short circuit in 320 nanoseconds. It limits current with constant power foldback so that the external FET stays inside its safe operating area, holds the undervoltage, overvoltage and power good thresholds to 1 percent, and sets a 20 millivolt default current limit across an external sense resistor.

Published values

ParameterValue
Short circuit response320 nanoseconds
Current limit20 mV default across the sense resistor, programmable
Foldbackconstant power, to keep the external FET inside its safe operating area
Monitor resolution12-bit analog to digital converter for current, voltage, power and temperature
Threshold accuracy1 percent on undervoltage, overvoltage and power good
BusPMBus fast mode, with peak detect registers for current, voltage and power
Fault handlingretry pin selectable between automatic retry and latch off
Model optionsADC accuracy of plus or minus 0.3, 0.7 or 1.0 percent depending on model
Package32-lead LFCSP
Application fitservers, telecom and datacom equipment, power budgeting and power monitoring

20 millivolts across the shunt sets the current

With a 1 milliohm sense resistor the 20 millivolt default limit is 20 A, and with a 2 milliohm resistor it is 10 A. The 12-bit converter resolves 20 millivolts into 4.9 microvolts per step, which at 1 milliohm is 4.9 mA per least significant bit. That is enough resolution to see a board's standby current and enough range to see its inrush, which is what makes the part a power monitor as well as a protector.

The converter measures across the same pins that the current limit uses, so the reported current and the protection threshold come from one element. A separate monitor amplifier with its own shunt would give two numbers that disagree, and the disagreement shows up in a system that bills power by the reported figure.

Constant power foldback and the FET rating

A current limit that holds a fixed current into a shorted output puts the full input voltage across the FET at the limit current, which is the worst point on its safe operating area curve. Constant power foldback reduces the current as the drain to source voltage rises, so the product of the two stays bounded and the FET is asked for a smaller area of its curve.

That still has to be checked against the timer. The controller limits how long the FET stays in current limit, and that time is set by a capacitor. A FET chosen only for its on resistance will pass the steady state test and fail the transient one, which is why the safe operating area curve of the chosen device belongs in the same review as the current limit resistor.

The -2 order code has its own pin figure

The data sheet carries separate pin configurations for the -1 and the -2, and the pin function table is written for the -1 and the -3. The -2 also has its own serial timing section, which tells you the interface arrangement is not identical across the family. A board that is being reworked from one model to another therefore has to be checked against the pin figure for the exact model rather than the table for its neighbour.

The model options table also ties the ADC accuracy to the model, with plus or minus 0.3, 0.7 and 1.0 percent versions. A system that budgets 1 percent for power reporting and receives a 0.3 percent part is fine; the reverse is not, and the difference is only visible on the order code.

Buyers usually arrive at the power management cross reference to find the family alternatives, then use the ADI second source page to confirm a substitute before it is fitted; how to verify a drop in replacement is the routine for a part that has already stopped shipping.

Two questions buyers ask

Can the ADM1278 replace a controller with an external sense amplifier? It integrates the sense amplifier and the converter, so the external parts reduce to the shunt, the FET and the timing capacitor. The threshold accuracy and the reported current then come from the part rather than from the tolerance of an external amplifier.

Is the PMBus interface required for the part to protect the board? No. Protection runs in hardware. The bus is for monitoring, thresholds and fault history, so a board with a dead bus still limits current and turns off on a fault.