The UCC28730DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

UCC28730DR: primary side regulated flyback controller for zero power standby

UCC28730DR is a primary side regulated flyback controller with a 700 V startup switch in a SOIC body of 7 pins. It regulates the output from the primary side, so the optocoupler and its drift disappear, and it holds standby consumption below 5 mW by entering a wake up monitoring state instead of keeping the loop alive. The 700 V startup switch charges the bias rail straight from the rectified line, and the maximum switching frequency is 83 kHz.

Order code and package

UCC28730DRD body, SOIC-7, 2500 pieces on a large reel, active
UCC28730Dthe tube row, 75 pieces, active
UCC28730 Q1the automotive member is a separate qualification document
Packingthe addendum prints only the 75 piece tube and the 2500 piece large reel for this body

Electrical parameters that decide the application

Standby powerbelow 5 mW at no load per the feature list
Regulationplus or minus 5 per cent voltage and current across line and load, primary side regulation with no optocoupler
Startup switch700 V rating on the HV pin, which charges the VDD capacitor directly from the bulk voltage
Startup current100 to 500 uA out of the HV pin at 100 V, with a 18 to 30 uA supply current in the start state
Bias thresholdsVDD turn on 17.5 V minimum, 21 V typical, 23 V maximum
Switching frequency83 kHz maximum, 30 Hz minimum
Protectionover voltage, low line and over current, with a clamped gate drive output
Featuresresonant ring valley switching, frequency dither for EMI, programmable cable compensation

Family variants and how they differ

D body tube75 pieces, active, for prototype quantities
D body reel2500 pieces on a large reel, active, the string on this page
Automotivethe Q1 string has its own document and its own addendum
Familythe device sits in the primary side regulated flyback family that carries the wake up monitoring function

Points to check before this part goes on a BOM

Primary side regulation removes the optocoupler and, with it, the part of the tolerance budget that ages fastest. The plus or minus 5 per cent figure covers line and load together, which is what makes the part usable in a charger that has to meet a tight no load voltage window without a secondary side reference.

The wake up monitoring state is the mechanism behind the 5 mW standby claim. Instead of keeping the switching loop alive at a low frequency, the controller sleeps and watches the feedback winding for the signature of a load event, so the output capacitor can be smaller than a burst mode stage would need.

The 700 V startup switch means the bias rail is charged from the rectified line without a resistor string. That removes the standing loss of a startup resistor, which on a wide input product can be the single largest contributor to no load consumption.

Valley switching on the resonant ring is what keeps the efficiency up at full load, and the frequency dither is what keeps the conducted emission inside the limit without a large common mode choke. Both are automatic and neither is programmed by the engineer.

The 83 kHz ceiling is deliberate. A higher frequency would shrink the transformer but raise the switching loss and the standby consumption, so the part is aimed at adapters and chargers where the transformer is small anyway and the standby number is what the customer measures.

The clamped gate drive output is what keeps the switching edge from ringing on a small transformer. The controller limits the drive voltage rather than letting it follow the bias rail, so the MOSFET turns on at a defined speed and the conducted emission stays inside the limit without a gate resistor network.

The 21 V typical turn on threshold is high for a bias rail built from an auxiliary winding, and that is deliberate. A high threshold means the controller does not start until the winding can supply the run current, so a board does not get stuck in a start attempt loop where the rail collapses every time the gate drive pulls current.

The plus or minus 5 per cent regulation window is quoted across line and load together, which is tighter than the same figure quoted at a single operating point. On a charger that has to hold 5 V at the plug, that is the number that decides whether cable compensation is needed at all or whether the window alone is enough.

The 30 Hz minimum switching frequency is what defines the light load behaviour before the controller sleeps. It is low enough that the transformer is effectively idle, and the wake up monitoring then takes over, so the transition between the two states is the part of the circuit that gets the most attention in the application section. That transition is also where the output voltage is most likely to drift, so the divider that sets the wake up threshold is worth measuring at both ends of the load range before a build is signed off.

What the minus 40 to 125 C range covers

The electrical table is specified over the full junction range with the bias at 25 V and the HV pin open, so the numbers are not room temperature figures. That matters on a charger that sits inside a sealed adapter shell, where the junction runs well above ambient at full load and the regulation window has to hold at both ends.

The cable compensation is a resistor from the CS pin, which lets the controller raise the output voltage as the load current rises and cancel the drop in the cable. On a fixed cable assembly that is the difference between meeting the output window at the plug and meeting it only at the board.

What the 700 V switch is protecting against

The HV pin sits on the rectified bulk, so on a 264 V AC input it sees close to 375 V DC and, with a surge, well above that. The 700 V rating is the margin for a line transient on top of the bulk voltage, and it is the reason the part can be used on a universal input without a pre regulator in front of the bias circuit.

The startup current out of the HV pin is 250 uA typical at 100 V, which is enough to charge the VDD capacitor in a predictable time and small enough not to heat the die. That figure is what sets the startup time of the whole supply, so a larger VDD capacitor buys holdup time at the cost of a slower first start.

Where this order code fits

Adapters and chargers for phones, tablets and consumer electronics, television and monitor supplies, and appliance and industrial SMPS are the applications the document names, and all of them are measured on standby consumption. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Pin to Pin Cross Reference page.

Questions buyers ask

Is an optocoupler needed? No. The regulation loop is closed on the primary side, which is what the plus or minus 5 per cent figure over line and load refers to.

How is the bias rail charged at startup? Through the 700 V switch on the HV pin, which charges the VDD capacitor from the rectified bulk voltage, so no startup resistor string is needed.

What is the highest switching frequency? 83 kHz. The minimum is 30 Hz, which is how the controller behaves at light load before it drops into the monitoring state.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.