TPS62A02PDDCR
Product Specifications
TPS62A02PDDCR
Texas Instruments — Power Management & Signal Chain
Product Overview
The TPS62A02PDDCR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS62A02PDDCR 2 A buck with power save operation
The TPS62A02PDDCR is the power save member of the TPS62A0x 2 A line in the DDC SOT-23 body. It runs from 2.5 V to 5.5 V, switches at 2.4 MHz at medium and heavy load, and enters power save at light load, where the frequency drops and the quiescent current falls below 23 microamp. The output is set by a divider on the FB pin from 0.6 V up to the input voltage, and the 100 per cent duty mode carries the rail to the end of a battery discharge.
The electrical detail is the family detail: 100 milliohm high side and 67 milliohm low side on the 2 A body, a 600 mV reference with a 591 mV to 609 mV window over temperature, 0.01 microamp of shutdown current and an undervoltage lockout between 2.3 V and 2.5 V rising. The difference between this part and the A member is the behaviour at light load, and that difference is the reason both exist: a rail that feeds a radio takes forced PWM, a rail that feeds a sleeping microcontroller takes power save.
Power save is not a burst mode with an uncontrolled ripple. The part reduces its switching frequency and holds the output in regulation with a low quiescent current, so a 3.3 V rail that supplies a real time clock and a memory retention domain keeps its voltage while the input current falls into the microamp range. For a product that runs on a coin cell or a small lithium cell, that mode is the difference between a year and a month.
Key parameters from the SLUSEG9E document
| Input range | 2.5 V to 5.5 V |
| Output range | 0.6 V to the input voltage through the FB divider |
| Output current | 2 A on this member |
| Switching frequency | 2.4 MHz at medium and heavy load, reduced in power save at light load |
| Switch resistance | 100 milliohm high side and 67 milliohm low side on the 2 A body |
| Feedback voltage | 600 mV nominal, 591 mV to 609 mV over the full temperature range |
| Quiescent current | Below 23 microamp in the non switching state |
| Shutdown current | 0.01 microamp typical |
| UVLO | 2.3 V to 2.5 V rising |
| Operation mode | Power save with automatic PWM to PFM transition at light load |
| Thermal note | Continuous 2 A below 3.3 V input or above 85 degrees ambient can reach thermal shutdown |
| Package | DDC SOT-23 body with six pins |
What power save does to a measurement
A converter that skips cycles produces a low frequency component in its output ripple, and that component sits in the band where an analogue front end or an audio path is most sensitive. On a rail that feeds a sensor bridge, the burst appears as a periodic offset in the reading, and it is often blamed on the sensor rather than on the supply. The remedy is either a forced PWM member or enough output capacitance and a small series ferrite to push the burst out of the band.
The quiescent current figure matters for the same reason it does in the nanoamp parts, only less so. At 23 microamp the converter is not the largest load in a sleeping product, but it is not negligible either, and the difference between power save and forced PWM at light load is three orders of magnitude in input current. A product that spends most of its life asleep takes the power save member without a second thought.
The 100 per cent duty mode is the same on both members. At 2 A the two switches in series drop about 330 millivolt, so a 3.3 V rail holds until the input falls to about 3.6 V and then follows the battery down. A customer who asks how the product behaves at the end of discharge is asking about this mode rather than about the switching behaviour.
Where this part fits
Battery powered instruments, wireless sensor nodes, portable medical devices and any board that needs 2 A in a leaded package with a low standby current. Our cross reference notes are at power management cross reference and the substitution check is at how to verify a drop in replacement.
What to check before a purchase order
Check the mode letter. The A members are forced PWM and this member is power save, and the two share a package and a pinout, so the reel label is the only way to tell them apart. A product that was characterised with one and built with the other will pass a functional test and may fail an emissions or a noise test.
Check the divider values and their tolerance. The 600 mV reference is low enough that a pair of 5 per cent resistors gives an output error of a few per cent, which on a 1.2 V rail is tens of millivolts. A 1 per cent pair costs almost nothing and removes the error term entirely. The receipt check is at incoming inspection plan.
Questions that come up on this part
Does the part hold regulation at no load, is a common question. It does, in power save, with the output held by the loop and the switching frequency reduced. The output ripple at no load is larger than at 2 A, which is the property to check against a load that is sensitive to ripple rather than to voltage.
The second question is whether the 2 A rating is available at 2.5 V input. The current limit allows it, but at 2.5 V in and 1.8 V out the duty cycle is high, the switches conduct for most of the period, and the loss at 167 milliohm in series is about 670 milliwatt. That is more than the SOT-23 body can remove at high ambient, so the usable current at the bottom of the input range is thermal rather than electrical.