Contact Us

TPS562231DRLR

Brand: Texas Instruments
Texas Instruments TPS562231DRLR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

TPS562231DRLR — Power Management & Signal Chain | Superb Automation

TPS562231DRLR

Texas Instruments — Power Management & Signal Chain

Product Overview

The TPS562231DRLR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TPS562231DRLR: a 2 A synchronous buck in a 1.6 mm by 1.6 mm six pin body with D-CAP3 control

TPS562231DRLR is a step down converter that produces up to 2 A from a 12 V rail with no external compensation, using a control loop that reacts to a load step within a few switching cycles in a SOT-563 body of 6 pins. The DRL body is 1.6 mm by 1.6 mm, which is the same footprint as a 0402 resistor pair, and the whole external circuit is an inductor, two capacitors and a divider.

Order code and package

Catalogue stringTPS562231DRLR, the DRL body with the R reel letter
BodySOT-563, six pins, DRL, 1.60 mm by 1.60 mm
Reel4000 pieces on a large tape and reel, which is a larger reel count than the 3000 that most parts of this size use
Finish and moistureLevel 1, 260 C, unlimited floor life on the plain row, while the .A row prints a tin finish and a call to the vendor for the plating
Temperatureminus 40 to 125 C junction
Marking2231
DocumentSLUSDA4B, revised October 2019
ControlD-CAP3, which is a fixed on time loop with no external compensation network

Electrical parameters that decide the application

Input range4.5 V to 17 V, which suits a 5 V or 12 V rail and not a 3.3 V one
Output range0.6 V to 7 V, set by a divider from a 0.6 V reference
Output current2 A, with a high side FET at 95 mOhm and a low side at 55 mOhm
Reference588 mV to 612 mV at 25 C, which is 2 per cent, and 600 mV typical across the full temperature range
Switching frequency850 kHz fixed, so the inductor and the ripple are set by the part and not by a resistor
Current limitthe low side FET source current limit runs 2.3 A minimum to 3.3 A maximum, which is a valley limit and therefore a peak limit about one ripple current higher
Lockout4.0 V rising and 3.6 V falling with 0.4 V of hysteresis, which is above a 3.3 V rail and rules that rail out
Quiescent current220 uA typical in the non switching state and 300 uA maximum
Shutdown current2 uA typical and 12 uA maximum with the enable pin at 0 V
Soft start1.5 ms internal, which bounds the inrush into the output capacitor without an external part
Undervoltage protection65 per cent of nominal with a 24 ms hiccup before restart, which is a latch and retry rather than a fold back
Thermal shutdown160 C with 25 C of hysteresis
Enable1.1 V to 1.42 V high threshold, with a 1000 kOhm resistance to ground, so a divider can set a precise lockout

The 2 A part, the 3 A sibling and what the control loop needs

TPS562231this device, 2 A in the DRL body
TPS563231the 3 A sibling in the same pinout, which is the part to quote when the load grows without a board change
TPS562201an earlier 2 A relative with a different control arrangement and a lower price point
TPS562231DRLRthe 4000 piece large reel row on this page
What the pinout buysthe 3 A part drops into the same six pads, so a board can be re rated without touching the copper
What the control changesno compensation components, at the cost of a loop that depends on the output capacitor characteristics

Points to check before this part goes on a BOM

The 2.3 A minimum current limit is close to a 2 A load. It is a valley limit measured on the low side FET, so the peak current is one ripple current above it, and a board that runs 2 A continuous with a 30 per cent ripple has a peak of 2.6 A against a 2.3 A floor. That is a board that will trip at full load on a cold day. The honest reading of the number is that 2 A is available with a modest inductor ripple, and 2 A with a large ripple is not.

D-CAP3 removes the compensation network and puts the burden on the output capacitor. The loop is stable with a wide range of capacitors and it is not stable with all of them, and the data sheet gives the window rather than a single value. A ceramic bank with a low equivalent series resistance is the intended load, and a circuit copied from a part with a voltage mode loop and an electrolytic output will oscillate.

The 4.0 V lockout rules out a 3.3 V input. This is worth stating plainly because the 2 A rating and the small body invite the assumption that the part works anywhere. A 3.3 V rail cannot start it and cannot keep it running, so the part is for a 5 V or 12 V input only. A 3.3 V to 1.2 V conversion needs a different device with a lower lockout.

850 kHz is fixed, which is a simplification and a constraint. The inductor is chosen for a ripple at that frequency, and there is no resistor to move it. On the positive side there is one fewer component to get wrong and the loop is characterised at the frequency it runs at. On the negative side a build that needs a smaller inductor for height reasons cannot trade ripple for size, and has to accept a larger ripple current.

The 4000 piece reel is unusual and worth noting on a quotation. Most parts of this size ship 3000 to a reel, so a production plan that assumes 3000 per reel under orders by 25 per cent on the first purchase and over orders on the last. The 250 piece row is the small reel, and the reel count is the sort of detail that a purchasing system reads from the offer rather than from the page title.

The hiccup protection at 65 per cent of nominal is a retry, not a latch. A shorted output pulls the rail down, the part stops switching for 24 ms and then tries again, which keeps the average dissipation low without needing an operator. Twenty four milliseconds of off time is long enough that a human hears a tick rather than a buzz, and short enough that a transient short recovers before the downstream device notices.

Sizing the inductor against a valley current limit

The limit is on the low side FET, which means it acts at the bottom of the ripple, and the peak current is one full ripple above that. With a 2.3 A floor and a 30 per cent ripple at 2 A, the valley is 1.7 A and the peak is 2.3 A, which just touches the limit. A 20 per cent ripple puts the valley at 1.8 A and the peak at 2.2 A, which leaves 100 mA of margin. That is the arithmetic behind the inductor value, and it is the reason a smaller inductor for a lower profile is not free.

The second constraint is the output capacitor. The ripple current the capacitor has to absorb is the inductor ripple divided by the square root of twelve, so a 20 per cent ripple at 2 A is 115 mA of capacitor current, and a single 10 uF ceramic is comfortable. The loop stability window is the other constraint, and it is what decides the minimum capacitance rather than the ripple.

What a fixed on time loop does on a load step

The loop reacts to the output voltage falling, not to a current error amplifier, so the response to a load step is a burst of full on time pulses rather than a controlled ramp. That is faster than a voltage mode loop with a compensation network and less predictable, because the on time is fixed and the off time is what the loop stretches. A 1 A to 2 A step produces a dip that recovers in a few switching cycles, at about 1.2 us per cycle.

The cost of that speed is a sensitivity to the output capacitor. The loop assumes a certain impedance at the switching frequency, and a capacitor bank that is far from it produces a response that overshoots or rings. Where the output capacitor is chosen for size alone, the transient looks worse than a slower loop would produce, which is the opposite of what the control was chosen for.

Where this order code fits

This is the point of load rail on a 12 V board, a digital television, a set top box, a network terminal, a surveillance unit or a smart meter, where 2 A has to come from a small package with no compensation parts Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the One Stop BOM Sourcing page.

Questions buyers ask

Can it run from 3.3 V? No. The lockout is 4.0 V rising and 3.6 V falling, so a 3.3 V rail cannot start the part. The input range is 4.5 V to 17 V and the lockout is consistent with that.

How much margin is there at 2 A? The valley limit floor is 2.3 A, so the peak current has to stay below that. At 2 A with a 30 per cent ripple the peak is already 2.3 A, which leaves no margin on a cold part. Keep the ripple at 20 per cent or accept a lower load.

Does it need a compensation network? No. The D-CAP3 loop is fixed on time and needs no external compensation, at the cost of a dependence on the output capacitor characteristics.

Why 4000 pieces on the reel? That is the quantity printed for the DRL row. It is higher than the 3000 that most parts of this size use, so a production plan that assumes 3000 will be short.

What happens on a shorted output? The part detects undervoltage at 65 per cent of nominal, stops for 24 ms and retries. It is a hiccup rather than a latch, so it recovers on its own once the short is removed.

SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the BOM Shortage Recovery page sets out the checks that keep a substitute from failing on the bench.