ISO7142CCDBQR
Product Specifications
ISO7142CCDBQR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO7142CCDBQR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO7142CCDBQR: four channels of isolation with input filters built in
The ISO7142CCDBQR is a quad channel digital isolator with two forward and two reverse channels in a 16 pin shrink small outline body. Its distinguishing feature is the filter on every input. In an industrial cabinet the input pin often sees a burst from a contactor coil or a cable that runs beside a drive output, and a filter inside the part removes short spikes before they reach the barrier instead of asking the board to add an RC network on four lines.
Isolation is 2500 VRMS for one minute under UL 1577 and 4242 VPK under DIN V VDE V 0884-10. The part runs from a single 2.7 V to 5.5 V rail on each side and translates between them, so a 3.3 V controller and a 5 V field interface can share the barrier without a level shifter. TTL input thresholds are used rather than CMOS ratios, which keeps a 3.3 V drive valid when the rail is 5 V.
The maximum signalling rate is 50 Mbps with 5 V supplies and 40 Mbps with 3.3 V or 2.7 V supplies. Propagation delay is 15 ns typical and 38 ns maximum at 5 V. Common mode transient immunity is 25 kV per microsecond minimum and 70 kV per microsecond typical, and the operating range starts at minus 55 C, which is wider at the cold end than most parts in this class.
Key data for the ISO7142CCDBQR
| Channels | Four, two forward and two reverse, each with an integrated input noise filter |
| Data rate | 50 Mbps with 5 V supplies, 40 Mbps with 3.3 V or 2.7 V supplies |
| Isolation | 2500 VRMS for 60 s per UL 1577, 4242 VPK per VDE V 0884-10 |
| Supply | 2.7 V to 5.5 V on each side, 2.7 V to 5.5 V translation, TTL input thresholds |
| Timing | Propagation delay 15 ns typical and 38 ns maximum at 5 V, 16 ns typical and 46 ns maximum at 3.3 V |
| Immunity | CMTI 25 kV per microsecond minimum and 70 kV per microsecond typical at 5 V |
| Current | 1.3 mA per channel typical at 1 Mbps, 2.5 mA per channel at 25 Mbps with 3.3 V supplies |
Body, packing and marking data
| Body | SSOP DBQ, 16 pins, 4.9 mm by 3.9 mm, the shrink body used where board area is tight |
| Packing | 2500 pieces on a large reel on the published rows, 75 pieces in a tube on the plain DBQ row |
| Finish | NIPDAU, moisture level 2, 260 C peak, one year floor life |
| Marking | 7142C on the body, which does not show the reel or the temperature grade |
| Temperature | Minus 55 C to plus 125 C |
What the filter changes in practice
A filter on the input adds a small delay and removes pulses shorter than its window. That trade is right for a status line or a slow bus, and wrong for a signal whose short pulses carry information. Before this part is chosen, the shortest legitimate pulse on each channel has to be compared with the filter window, and any channel that carries a narrow pulse should be moved to an unfiltered isolator in the same family.
The filter also changes the fault signature. A marginal connection that used to show up as a stream of glitches now shows up as a missing edge. That is easier to diagnose but it appears later, so a production test that only looks for glitches will pass a board with a weak connector. Check the edge timing on the first article rather than the presence of noise.
Where four channels with filters are used
Motor control, solar inverters and industrial automation boards use this part where the isolation boundary sits next to switching hardware. The two reverse channels usually carry enable and fault, and the two forward channels carry a clock and data or a pair of commands. The cold end of the temperature range reaches minus 55 C, which is why the part also turns up in outdoor and transport equipment.
For projects where the barrier is part of a medical submission, our medical device component sourcing page lists the documents a reviewer will ask for, and the incoming inspection plan page covers how to verify a barrier part at goods inwards without destructive testing.
Questions we get on this code
Buyers ask whether 2500 VRMS is enough. It is enough for basic isolation at mains voltages up to the working voltage the certificate names, and it is not a reinforced rating for a 600 V working voltage. The certificate, not the headline number, decides the answer, and the certificate lists the working voltage separately from the withstand voltage.
The second question is about the tube versus the reel. The plain DBQ row ships 75 pieces in a tube and the R suffix row ships 2500 on a reel. Both are the same die. An order written without the suffix will arrive in a tube, which is fine for a prototype and awkward for a line that expects a feeder.