Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
TPS51362RVER: 22 V Input, 10 A Converter With the FETs Inside and 100 uA Standby
TPS51362RVER is a synchronous step-down converter with both FETs integrated in a 28-pin QFN body of 28 pins. It takes 3 V to 22 V at the input, holds 0.6 V to 2 V at 10 A, switches at a fixed 800 kHz, and drops its own bias current from 560 uA to 100 uA when the LP# pin is pulled low.
Order code and package
| Ordering string | TPS51362RVER, QFN-28 (RVE), 3.5 mm by 4.5 mm by 1.0 mm, 0.4 mm pitch |
| Input | 3 V to 22 V at VIN, 4.6 V to 5.5 V at the V5 bias pin |
| Output | 0.6 V to 2 V adjustable through REFIN and REFIN2 |
| Current | 10 A with the high-side and low-side FETs inside the package |
| Switching frequency | 800 kHz fixed, no resistor to set it, one frequency for the whole family |
| Output capacitors | D-CAP2 loop, works with POSCAP, SP-CAP or all ceramic |
| Temperature | -10 C to +85 C ambient, the cold end is the constraint |
Electrical parameters that decide the application
| Bias current | 100 uA in ULQ mode with LP# low, 560 uA normal, 1 uA shutdown |
| Reference | 2 V at VREF, plus or minus 1 percent from 0 uA to 300 uA of load |
| Minimum off time | 320 ns, 25.6 percent of the 1.25 us period at 800 kHz |
| V5 undervoltage lockout | 4.3 V minimum, 4.4 V typical, 4.6 V maximum on the wake threshold |
| Thermal resistance | 40.2 C/W junction to ambient, 22.8 C/W junction to case top, 1.6 C/W bottom |
| Soft start | 10 uA into the SLEW capacitor, so the ramp time is set by capacitance |
| Current limit | two levels selected at the TRIP pin, low-side sensing, temperature compensated |
| Status | power good output, output discharge, OVP at 120 percent typical |
Points to check before this part goes on a BOM
The standby number is the feature: 100 uA in ULQ mode against 560 uA in normal operation is 460 uA saved, which is 876 mAh a year at the low figure and 4.9 Ah at the high one. On a 5000 mAh battery the difference between the two states is 17.5 percent of the pack over a year of shelf time, so LP# has to be driven by the system and not tied low by mistake.
The specified ambient range starts at -10 C, not -40 C. A product sold into an industrial cold start, a freezer or a winter vehicle cabin is outside the part at the bottom of the table, and the certification of the assembly follows the datasheet, not the marketing temperature line.
320 ns of minimum off time is 25.6 percent of the 1.25 us period, so the maximum duty is 74.4 percent. A 2 V output from a 3 V input needs 66.7 percent and fits, while the same 2 V output from a 2.5 V input needs 80 percent and does not: the converter falls out of regulation rather than tripping a protection, which shows up as a rail that sags instead of a fault flag.
Ten amps at 1.05 V is 10.5 W, and at 90 percent the loss is 1.17 W inside the 28-pin body. At 40.2 C/W that is a 47 C rise, so an 85 C ambient puts the junction at 132 C with no margin for the inductor loss that also lands on the same copper. The 1.6 C/W junction to case bottom figure is the path that saves it, which means the exposed pad and its vias are the thermal path and not an afterthought.
The 2 V reference is plus or minus 1 percent, which is 20 mV, and a 1.05 V output takes half of it through the REFIN divider, so 10 mV or 0.95 percent arrives from the reference alone before the two resistors contribute. A 1 percent resistor pair doubles that, and the total is the number that belongs on a rail accuracy line rather than the reference figure.
Current limit is sensed across the low-side FET and the feature list says it is temperature compensated, which is the right question to ask because an uncompensated RDS(on) sensor moves by tens of percent over the junction range. The TRIP pin offers two levels, so the same part serves a 6 A rail and a 10 A rail without a different order code.
The soft start ramp is a current into an external capacitor, 10 uA into the SLEW pin, so the time follows capacitance directly: 12.5 nF gives 1 ms to 0.8 V and 125 nF gives 10 ms. The same pin sets the integrator time constant, so a slow ramp also slows the loop, and a board that lengthens the ramp for an inrush limit has to recheck its transient response afterwards.
Where this order code fits
It is built for notebook VCCIO and DDR VDDQ rails, memory termination supplies and other point-of-load rails that sit behind a 12 V to 20 V adapter and have to keep a battery alive in standby, and the same 800 kHz loop is used in thin clients, panel electronics and portable instrument supplies. Teams comparing it with a neighbouring part start from our Power Management Cross Reference page, and teams replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Is the 5 V bias separate from the input? Yes. VIN takes 3 V to 22 V and V5 takes 4.6 V to 5.5 V with a 4.4 V typical lockout, so the bias rail has to come up with or before the main input.
Can it be used at -40 C? No. The operating free-air range is -10 C to +85 C, and that is the temperature the assembly has to be qualified to.
Is 10 A available at 85 C ambient? Only with the copper and airflow the 40.2 C/W figure assumes; at 85 C the pad and vias set the real continuous current.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Pin to Pin Cross Reference page sets out the checks that keep a substitute from failing on the bench.