Product Overview

The TL441CN from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

TL441CN: logarithmic amplifier with four 30 dB stages in a 14 pin DIP body

TL441CN is a piecewise logarithmic amplifier built from four cascaded 30 dB stages, giving a differential output that is linear in decibels over roughly 120 dB of input range in a PDIP body of 14 pins. The N suffix is the 14 pin dual in line body and the C suffix is the 0 to 70 C grade. The device runs from plus or minus 6 V, draws 14.5 to 23 milliamps from the positive rail and 6 to 10.5 milliamps from the negative rail, dissipates 123 to 201 milliwatts, and produces a differential output that moves 6 to 12 millivolts per decibel on dc and 8 millivolts per decibel on ac, with rise time of 20 to 30 nanoseconds into a 24 picofarad load.

Order code and package

Order codeTL441CN
Functionlogarithmic amplifier and multiplier, four 30 dB stages
PackagePDIP, 14 pins, body code N
Supply rangeplus or minus 6 V nominal, plus or minus 8 V absolute maximum
Positive supply current14.5 mA typical, 23 mA maximum
Negative supply currentminus 6 mA typical, minus 10.5 mA maximum
Dissipation123 to 201 milliwatts
DC scale factor6 to 12 mV per dB per stage
AC scale factor8 mV per dB
Rise time20 to 30 nanoseconds into 24 pF
Input impedance500 ohms
Output impedance200 ohms
Temperature range0 to 70 C, C grade

Electrical parameters that decide the application

Input range per stage0.01 to 1 V peak to peak
Differential output offsetplus or minus 40 mV
Quiescent output voltage5.45 to 5.85 V
DC error at midpoint1 dB at minus 20 dBV
Output sink current30 mA absolute maximum
Input voltage limit6 V absolute maximum
Thermal resistance67 C per watt junction to ambient
Stage countfour stages of 30 dB
Summingexternal network sums the stage outputs
Output typedifferential current into an external load
Package14 pin DIP, 0.3 inch
DatasheetSLVS328, October 2000

Points to check before this part goes on a BOM

The log law is piecewise, not continuous. Four 30 dB stages hand over from one to the next, and the handover points are where the slope error is largest: the data sheet quotes 1 dB of dc error at minus 20 dBV, the midpoint of one stage's span, not at the handover. A measurement that needs better than 1 dB over 120 dB has to be calibrated at multiple points.

The scale factor is given as a range, 6 to 12 millivolts per decibel, and that is a per device spread rather than a temperature drift. Two parts in the same receiver can differ by a factor of two in slope, so a board that converts the output voltage to decibels with a fixed constant will be wrong on half the units and has to be calibrated per board.

Rise time of 20 to 30 nanoseconds sounds fast until the 24 picofarad load is included. The output is a current into an external summing network, and the capacitance of that network, plus the cable to the next stage, sets the bandwidth. A 100 picofarad load roughly quadruples the rise time and turns a 10 MHz detector into a 2 MHz one.

Supply current is asymmetric and large for an analogue part. 23 milliamps from the positive rail and 10.5 milliamps from the negative is 33.5 milliamps total, about 400 milliwatts at plus or minus 6 V, while the device itself dissipates 201 milliwatts. The rest is delivered to the external output network, so the load resistors are part of the thermal budget.

The input impedance of 500 ohms is low, and it is not constant with level. A 50 ohm source driving this input sees a 10 to 1 mismatch, which is tolerable for a level detector and is a problem for a measurement that has to preserve the source's own matching. An attenuator pad and a buffer are the usual interface.

The quiescent output of 5.45 to 5.85 V on a 6 V rail means the output sits close to the positive rail at zero signal. Downward swing is the useful direction, and the 40 mV differential offset is small against a 6 to 12 millivolt per decibel slope, but the single ended output has only about 0.5 V of headroom above it before clipping.

Where this order code fits

Received signal strength indicators in radio receivers, ultrasound and radar logarithmic detectors, and audio level compression all use a piecewise log amplifier. A true log detector that covers 100 dB of input range in one stage is difficult to build, and four 30 dB stages plus a summing network is the classical way to do it. Boards comparing it with a neighbouring part start from our RF Component Sourcing page, and boards replacing a part that has gone end of life start from the Amplifier Cross Reference page.

Questions buyers ask

How many decibels of input range does this part cover? Four stages of 30 dB give about 120 dB of nominal span, with 0.01 to 1 V peak to peak per stage. The usable range is smaller once the 1 dB midpoint error is applied at each handover.

Is the output voltage or current? A differential current that is summed by an external network into a voltage. The 6 to 12 millivolt per decibel scale factor assumes the recommended network, so changing the load resistor changes the slope.

Can it run from plus or minus 5 V? The table is written at plus or minus 6 V and the absolute maximum is plus or minus 8 V. Running at plus or minus 5 V reduces the output headroom, which is already only about 0.5 V above the quiescent point.

SUPERB holds and sources this Texas Instruments line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a line is moving, the How to Verify a Drop in Replacement page sets out the checks that keep a substitute from failing on the bench.