Contact Us

ADXL355BEZ-RL7

Brand: Analog Devices
Analog Devices ADXL355BEZ-RL7 is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

ADXL355BEZ-RL7 — Analog & Mixed-Signal ICs | Superb Automation

ADXL355BEZ-RL7

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The ADXL355BEZ-RL7 from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

ADXL355BEZ-RL7: A Hermetic 20 Bit Accelerometer for Tilt and Seismic Work

What this part is

The ADXL355 is a three axis MEMS accelerometer with a 20 bit converter and ranges of plus and minus 2, 4 and 8 g. The package is hermetic, which is the detail that separates it from the plastic parts in the same catalogue: a hermetic cavity keeps moisture and the slow mechanical creep that follows it out of the sensor, and the offset stability over years is the reason a seismic or structural monitoring channel can be left installed without a periodic re-zero.

The noise density is 22.5 micrograms per root hertz on all three axes and the zero g offset drift is 0.15 milligrams per degree C maximum, which is a maximum rather than a typical figure. Data leaves over SPI or I2C, the part has programmable high pass and low pass digital filters, a data interpolation routine for synchronous sampling, an integrated temperature sensor and an electromechanical self test. Supply is 2.25 V to 3.6 V with the regulators in use, or 1.8 V with them bypassed, current is 200 microamps while measuring, and the body is a 14 terminal hermetic LCC of 6 mm by 5.6 mm by 2.2 mm.

Published figures that matter to a buyer

Rangesplus and minus 2 g, 4 g, 8 g
Converter20 bit
Noise density22.5 micrograms per root hertz, all axes
Zero g offset drift0.15 milligram per degree C maximum
Supply with regulators2.25 V to 3.6 V
Supply with regulators bypassed1.8 V typical, plus or minus 10 percent
Current in measurement200 microamps
Current in standby21 microamps
InterfaceSPI and I2C
Filtersprogrammable high pass and low pass, digital
Body14 terminal hermetic LCC, 6 mm by 5.6 mm by 2.2 mm
Temperatureminus 40 to plus 125 degrees C

Where the headline numbers stop

The count size changes with the range. On plus and minus 2 g a count is 3.815 micrograms, on plus and minus 8 g it is 15.26 micrograms. At 22.5 micrograms per root hertz over a 100 Hz band the noise is 0.23 mg rms, which is 59 counts on the 2 g range and 15 counts on the 8 g range: the same sensor has four times the effective resolution at the lower range, so the range should be chosen as the smallest that covers the expected motion rather than the largest that fits.

The offset drift of 0.15 mg per degree C maximum over 165 degrees is 24.8 mg, which is 6,501 counts on the 2 g range. That is the figure that decides whether the part is usable for long term tilt: a milligram of tilt near horizontal is 0.057 degrees, so 24.8 mg of drift is about 1.4 degrees of apparent tilt over the full temperature span unless the channel is zeroed at the operating temperature. The hermetic body reduces the slow term, it does not remove the temperature term, and the temperature sensor in the part is there so the host can compensate it.

Over a 1 kHz band the noise of 22.5 micrograms per root hertz is 0.71 mg, which is a 0.04 degree tilt error at 100 Hz of bandwidth and four times that at 1 kHz. Narrowing the digital low pass filter is the cheapest way to buy resolution in a static measurement, and it costs response time rather than power.

Applications where it fits

  • Inertial measurement units and heading reference systems where the zero has to survive temperature and time.
  • Structural health monitoring on bridges, towers and machinery foundations.
  • Seismic and vibration recording, where the 2 g range is used with a narrow band.
  • Tilt sensing on survey and platform levelling equipment.
  • Condition monitoring of rotating machinery in a sealed enclosure.

Two questions buyers ask

Is the ADXL354 a substitute? The ADXL354 is the analogue output member of the same family with the same sensing element and the same ranges, so it is a substitute only where the host has its own converter and the offset drift budget allows it. The digital part carries the filters and the interpolation, and those are the functions that would have to be rebuilt.

Why does a hermetic package matter in a sealed instrument? Because the drift that hurts a tilt channel is slow and is often mechanical rather than electrical, and moisture in a plastic cavity is a contributor to it. A hermetic cavity removes that path. It does not remove the temperature coefficient, which is why both the hermetic body and the temperature sensor appear in the same part.

Sourcing notes and next step

ADXL355BEZ-RL7 is the hermetic LCC body on tape and reel, and the BEZ field is the body and finish code, so a cross reference has to match the body rather than the family name. The medical device components page covers the traceability a monitoring instrument needs, the lead time page sets out the route when a hermetic sensor is quoted long, and the analog and mixed signal IC family page lists the rest of the sensor line.

Request Quote — In Stock, 100% New & Original, Full Warranty