Contact Us

LM239DRG3

Brand: Texas Instruments
Texas Instruments LM239DRG3 is a power management component designed for Industrial Automation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LM239DRG3 — Power Management & Signal Chain | Superb Automation

LM239DRG3

Texas Instruments — Power Management & Signal Chain

Product Overview

The LM239DRG3 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

LM239DRG3: the older green code on a quad comparator reel, and what the addendum says about it

LM239DRG3 is the quad differential comparator in the fourteen pin small outline body, on a 2500 piece reel, under the older G3 material code. Electrically it is the plain LM239 grade, with the 5 millivolt offset maximum at room temperature and the minus 25 to plus 85 window, not the tighter A sort.

The interesting part of this string is the last two characters. G3 and G4 both mean a lead free, RoHS compliant body, and the difference between them is which declaration the vendor files under. That difference has cost several programmes a line stop, because a bill of materials that names G3 cannot be filled from a shelf that holds G4, even though the parts are the same die in the same body.

What the addendum prints for this code

The orderable addendum attached to the current revision of the family document prints LM239DRG3 with the status obsolete. LM239DRG4 beside it is printed as active. The two rows share the body, the pin count, the window and the die, and the only difference on the page is the material code and the status column.

Orderable codeLM239DRG3
Status on the current addendumobsolete
Comparators per body4, independent
BodySOIC, 14 pins
Carrierlarge tape and reel
Offset gradeplain, 2 millivolts typical
Offset maximum at 25 degrees5 millivolts
Offset maximum over the window9 millivolts
Temperature windowminus 25 to plus 85 degrees
Supply voltage2 to 36 volts
Supply current0.8 milliamps typical, 2 maximum
Response time1.3 microseconds typical
Outputopen collector, 36 volts, 16 milliamps sink
Active siblingLM239DRG4

The electrical rows that do not depend on the material code

The plain grade holds 2 millivolts typical and 5 millivolts maximum at 25 degrees, widening to 9 millivolts over the minus 25 to plus 85 window. The A sort next to it holds 3 and 4 over the same window, which is the difference a threshold chain has to be sized against. Bias current is 25 nanoamps typical and 250 maximum at room, widening to 400, and offset current is 5 nanoamps typical with 50 maximum, widening to 150.

The input range reaches ground and stops 1.5 volts below the positive rail at room, 2 volts over the window. That is the row that lets a comparator watch a shunt on the low side of a load, or a cell at the bottom of a stack, without a negative rail. A part that only reached within 1.5 volts of ground would need a charge pump for the same job.

Gain is 50 volts per millivolt minimum and 200 typical, which is enough to turn a 5 millivolt step into a full output swing on a 5 volt pull up. The output sinks 16 milliamps typical at 1.5 volts and drops 150 millivolts at 4 milliamps, so a small optocoupler or a logic gate is a direct load and a relay is not.

G3, G4 and the declaration behind the letters

Both codes declare a lead free finish and RoHS compliance. The G3 code is the older convention and the G4 code the newer one, and the vendor keeps them as separate orderable rows because customers qualify a material declaration, not just a part. A drawing that says G3 is a drawing that was qualified against a specific declaration document, and the substitution is a paperwork event even when the physical parts are indistinguishable.

In practice there are three routes when a bill of materials still names G3. The first is to buy remaining stock of the obsolete row, which works while it lasts. The second is to change the bill of materials to G4, which needs the customer's approval because the material declaration reference changes. The third is to buy G4 and ship it against a deviation, which is the fastest and the one that leaves the weakest audit trail.

Material codeG3, older declaration
Equivalent current codeG4
Die and bodyidentical between the two
Electrical tableidentical between the two
Status differenceG3 printed obsolete, G4 printed active
Substitution typepaperwork change, not a form fit function change
Approval neededmaterial declaration revision, from the customer
Risk if skippedaudit finding on a declaration that no longer matches the shipment

What to do with a reel that is already on the shelf

An obsolete orderable row is not an obsolete part. The silicon is the same as a part that is still being built, so stock that was bought before the change is perfectly usable, and the question is only how much of it is left and how long the build runs. That is an arithmetic question with a date on it: annual usage, remaining stock, and the date the customer's drawing will be revised.

Our component obsolescence management page covers that arithmetic and the notification route, and the obsolete part cross reference hub is where we keep the family notes when an orderable row is withdrawn. A quad comparator with four active siblings rarely needs a new circuit, and the work is nearly always in the paperwork.

The bill of materials side is worth one pass before the next build. The BOM scrubbing page describes how we look for exactly this pattern, an orderable code that is obsolete while an identical active code sits beside it, and how the change is proposed to the customer without touching the approved drawing record.

Where the withdrawn codes still sit in the market

An obsolete orderable row does not disappear from the market on the day it is flagged. Broker stock, distributor stock and consignment stock keep circulating for years, and the parts are genuine because they were built before the withdrawal. The risk is not counterfeit silicon, it is a date code that is older than the customer's control plan allows and a reel label that no longer matches a live addendum row.

That changes the questions to ask when buying the withdrawn code. Ask for the date code and the original packaging, ask whether the reel is a factory reel or a repack, and ask for the material declaration that was in force when the parts were built. None of those questions is about the electrical table, because the electrical table never changed.

What to write in the change note

A material code change note needs four lines to be useful. The old string, the new string, the field that changed, and the evidence that nothing else did. On this family the evidence is that the die, the body, the pin count, the window and every electrical row are identical between the two rows, which is a comparison anyone can repeat from the addendum.

What the note must not do is imply a performance change in either direction. A G3 to G4 move is neither an upgrade nor a downgrade, and a customer who reads it as an upgrade will ask why the price did not move.

Once the note is approved, the bill of materials carries one live code and the obsolete row is deleted rather than left as an alternate. An alternate line that cannot be bought is a trap for the next buyer, and it is the most common reason a line stops for a part that is actually in stock under a different string.

Questions that come with this code

Can G4 be shipped against a G3 line without a note? Not on a controlled programme. The parts will work, and the material declaration on file will no longer describe the shipment, which is the kind of finding that costs more to close than the price difference on the reel.

Is the A grade a substitute? Only if the threshold budget allows a different offset window, and the pinout and the body are the same, so the change is electrical rather than mechanical.

How do I know which code is on the shelf? The part marking does not carry the material code on this family, so the reel label is the only evidence, and the label is what the traceability record has to quote.