Product Specifications
ISO6731FDWR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO6731FDWR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO6731FDWR: A Triple at 50 Mbps With Two Channels Out and One Back
ISO6731FDWR is a general purpose triple channel digital isolator in a SOIC (DW) body of 16 pins. It moves three lines at 50 Mbps across a 5000 VRMS barrier, two forward and one back, with 11 ns typical delay, 1.6 mA per channel at 1 Mbps, enable pins on every output and a projected barrier life of 36 years.
Order code and package
| Ordering string | ISO6731FDWR |
| Package | SOIC, 16 pins, DW wide body, 10.30 mm by 7.50 mm nominal |
| Carrier | 2000 pieces on a large reel |
| Sibling rows | ISO6731FDWR.A at the same 2000 pieces, ISO6731DWR for the high default |
| Moisture level | Level 2, 260 C peak reflow, one year floor life |
| Temperature range | Minus 40 to plus 125 degrees Celsius |
| Part marking | ISO6731F |
| Tube rows | None printed in this addendum, the family ships on reel only |
| Channel direction | Two channels forward, one reverse |
| Default output | Low, set by the F suffix |
Electrical parameters that decide the application
| Signaling rate | 50 Mbps |
| Isolation rating | 5000 VRMS per UL 1577, tested at 1.2 times for one second on every unit |
| Maximum repetitive peak voltage | 2121 VPK |
| Maximum working voltage | 1500 VRMS and 2121 VDC |
| Maximum transient voltage | 7071 VPK |
| Maximum impulse voltage | 7692 VPK |
| Maximum surge voltage | 10000 VPK, 1.2 by 50 microsecond waveform |
| Common mode transient immunity | 100 kV per microsecond minimum, 150 kV per microsecond typical |
| Supply range | 1.71 to 1.89 V, or 2.25 to 5.5 V, set independently on each side |
| Level translation | 1.71 V to 5.5 V |
| Supply current per channel | 1.6 mA typical at 1 Mbps |
| Propagation delay | 11 ns typical |
| External clearance | Above 8 mm |
| Distance through insulation | Above 17 micrometres |
| Tracking index | Above 600 V, material group I |
| Barrier capacitance | About 1 pF from input to output |
| Projected barrier life | 36 years by the time dependent breakdown test, against a 30 year minimum requirement |
| ESD across the barrier | Plus or minus 8 kV IEC 61000-4-2 contact discharge |
| Enable pins | One per output, driving the output to high impedance |
| Climatic category | 40/125/21, pollution degree 2 |
Family variants and how they differ
| ISO6731DWR | The same triple with the high default |
| ISO6731FDWR.A | The same reel quantity with the alternate finish paperwork |
| ISO6741FDWR | A quad at 50 Mbps with three forward and one reverse when a fourth line appears |
| ISO6721FBDR | A dual with one channel each way when only two lines are needed |
| ISO7641FMDWR | A quad at 150 Mbps in the same wide body when the rate has to rise |
| ISO7842FDWWR | An 8000 VPK reinforced quad in the extra wide body when the barrier has to be higher |
Points to check before this part goes on a BOM
The document records two revisions worth knowing. The common mode immunity was raised from 50 kV minimum and 75 kV typical to 100 and 150, and the surge rating was raised from 6250 VPK to 10000 VPK, so a page that still quotes the older figures is quoting a superseded revision.
The working voltage is 1500 VRMS with a 2121 VPK repetitive peak, which sits between the basic duals at 450 VRMS and the reinforced parts at 1500 VRMS with a wider body. Boards mixing the two families side by side on one barrier need the lower rating applied to the whole barrier, not to each part.
Enable pins are per output. They put the output into high impedance, not into the default level, so a shared line still needs a pull resistor that holds it where the system expects while the channel is off.
The barrier life projection is 36 years, against a 30 year minimum that the standard requires for this class. That is a margin rather than a promise of service life, and it is quoted at the rated working voltage rather than at the transient rating.
2000 pieces on a reel is the only packing. A build of a few hundred boards takes a cut tape or stock rather than a full reel, and the reel commitment is the reason this part is often held in a kitting programme instead of being bought per job.
1.6 mA per channel at 1 Mbps is the lowest figure in this family at 50 Mbps, and it is why the part appears in loop powered and battery backed boards where the barrier current has to be small.
The three line interface this part was built for
An isolated RS-485 node needs a driver enable, a receiver enable and a data line, or a UART pair and one direction control, and both arrangements are three lines with at least one running back. The two forward and one reverse split matches that without leaving a channel unused.
An isolated gate drive that also reports a fault uses two lines forward and one back, and a bi-directional SPI link in a three wire arrangement uses the same count. Where the third line runs forward, the quad at the same rate replaces the triple without a change of body.
Where 1500 VRMS working voltage is enough
Inside equipment that runs from a low voltage supply, the barrier only has to separate grounds and break a fault path, and 1500 VRMS with a 2121 VPK peak is comfortably above the stress. The part then competes on rate, current and price rather than on the barrier.
Across a mains boundary the same part is used where the working voltage on the barrier stays under its rating and the clearance of more than 8 mm is achieved on the board. Above that, the extra wide body becomes the only option and the 8000 VPK family is the one to quote.
Three channels without a spare
A triple is a deliberate size. It covers an isolated UART with a direction control, an RS-485 node with two enables, or a gate drive with a fault return, and it leaves no channel to waste. Where a fourth line appears the quad at the same rate fits the same body and the same reel quantity.
The cost of the third channel is small against a quad, and the saving against two duals is significant in area. That is why the triple survives in a market that otherwise sells quads and duals.
How the enable pins behave in a shared bus
Each output has its own enable and the disabled state is high impedance. Two isolators can therefore share one line, provided the line has a pull resistor that settles it while both are off and provided the firmware never enables both at once.
The enable is not a power down. The channel keeps its bias and the far side keeps its supply, so the current saving is small and the timing on re-enable is short. Boards that use the enable as a power switch are using it for something it was not built to do.
Where this order code fits
It is chosen where three digital lines cross one barrier and the working voltage sits under its 1500 VRMS rating, most often on an isolated RS-485 node or a gate drive with a fault return. Teams comparing it with a neighbouring part start from our Strategic Sourcing page, and teams replacing a part that has gone end of life start from the Supplier Quality Audit page.
Questions buyers ask
Does the revision change affect a part already on the shelf? The higher common mode and surge figures come from a document revision, not from a change of die in the field. A part bought against the older revision still meets the older figures, so an application that relies on 10000 VPK of surge should be quoted against the current revision.
Can two outputs share one line? Only with a pull resistor and only if both channels are never enabled at the same time. The enable puts the output into high impedance rather than driving a level, so the line has to be held by something else while both are off.
Is there a tube option? No tube row is printed for this family. The 2000 piece reel is the only carrier, which is why small builds are usually served from cut tape or from a kitting stock rather than from a sealed reel.
SUPERB holds and sources this line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a part is moving, the Kitting Service page sets out the checks that keep a substitute from failing on the bench.