INA331IDGKR
Product Specifications
INA331IDGKR
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA331IDGKR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA331IDGKR: the tighter grade on a 2500 piece reel
INA331IDGKR is the tighter of the two grades in the 8 pin VSSOP, on a 2500 piece large reel, with a maximum offset of 500 microvolts at 25 degrees and 1.7 millivolts over the full minus 55 to plus 125 degree window. The internal gain of 5 is trimmed to 0.02 per cent and the gain drift is 2 ppm per degree.
That offset column is what the grade buys, and the rest of the part is the family's: 415 microamps per channel, 0.01 microamps in shutdown, 2 MHz at a gain of 25 and 94 dB of rejection at a 5 volt supply. On a 10 millivolt bridge the 500 microvolt maximum is five per cent of full scale, which is a calibration step rather than a blocker, and the 1.7 millivolt over temperature envelope is the number the calibration has to cover.
INA331IDGKR as the vendor document publishes it
| Gain | 5 V/V fixed inside the package, 5 plus 5 times the external ratio above 5 |
| Gain error at 5 | 0.02 per cent typical, 0.1 per cent maximum |
| Gain drift | 2 ppm per degree typical, 10 ppm per degree maximum |
| Offset voltage | 250 microvolts typical, 500 microvolts maximum |
| Offset over temperature | 1.7 millivolts |
| Offset drift | 5 microvolts per degree |
| Common mode rejection | 90 dB minimum, 94 dB typical at a 5 volt supply |
| Common mode rejection at 45 kHz | 50 dB |
| Input bias current | 0.5 picoamps typical, 10 picoamps maximum |
| Input impedance | 10 to the 13 ohms in parallel with 3 picofarads |
| Common mode range at 5 volts | 0.55 volts to 3.8 volts |
| Common mode range at 2.7 volts | 0.35 volts to 1.5 volts |
| Supply range | 2.7 volts to 5.5 volts |
| Quiescent current per channel | 415 microamps typical, 490 microamps maximum |
| Shutdown current | 0.01 microamps typical, 1 microamp maximum |
| Bandwidth at 3 dB | 2 MHz at a gain of 25 |
| Slew rate | 5 volts per microsecond |
| Voltage noise at 1 kHz | 46 nanovolts per root hertz |
| Output swing from the rail | 20 millivolts, at a gain of 10 or above |
| Stable load capacitance | 500 picofarads |
| Temperature range | minus 55 to plus 125 degrees |
| Body | VSSOP, 8 pin, DGK, 3.00 by 3.00 millimetres |
| Vendor status | active, 2500 piece large reel |
| Catalogue code | INA331IDGKR |
| Vendor string | INA331IDGKR |
| Grade | I, 500 microvolts maximum offset |
| Marking | C31 |
| Moisture level | level 2, 260 degrees, one year floor life |
Five volts per volt is trimmed inside the package
INA331IDGKR carries its gain network inside the package at a fixed 5 V/V, built from a 10 kilo-ohm and a 40 kilo-ohm pair. That internal five is trimmed, which is why the gain error is 0.02 per cent typical and 0.1 per cent maximum at a gain of 5, and why the gain drift is 2 ppm per degree typical and 10 maximum. A channel that needs exactly 5 can use the part with the gain pins open and no external network at all.
Any gain above 5 comes from one external resistor pair as 5 plus 5 times their ratio, up to about 1000. The internal trimming stops at the package pins: at a gain of 100 the accuracy is the resistor pair, not the amplifier, so a 1 per cent pair gives a 1 per cent channel and a 0.1 per cent pair gives 0.1 per cent. The pair also sets the drift, and its temperature coefficient adds directly to the 2 ppm per degree of the internal network.
Four hundred and fifteen microamps, and one hundredth of a microamp asleep
INA331IDGKR draws 415 microamps typical and 490 microamps maximum per channel, and 0.01 microamps with the shutdown pin pulled low. The return from shutdown takes microseconds, which is fast enough for the part to be powered per reading rather than left running: a battery instrument that measures once a second for 2 milliseconds spends a fifth of one per cent of its life in measurement, and the rest of the time the front end is off.
That is what makes the part usable in a multichannel logger. The shutdown pin is brought out on the single, and the dual brings it out for both channels together rather than per channel, so a dual used for two sensors is either awake for both or asleep for both. The quiescent current is also the largest single term in the error budget of a small battery instrument: 415 microamps is a quarter of what a coin cell can deliver for a year, and the converter behind the amplifier usually draws less than the amplifier does.
Two hundred and fifty microvolts, and the grade that doubles it
The offset of INA331IDGKR is 250 microvolts typical at a 5 volt supply, and the maximum column is where the two grades separate: 500 microvolts on the I grade and 1 millivolt on the A grade. The same table prints the offset over the whole temperature range at 1.7 millivolts and 2.1 millivolts, so the 25 degree figure is not the one to budget against.
That gap between the room temperature and the over temperature row is the honest cost of a CMOS input stage without a chopper. The offset drift is 5 microvolts per degree in the table, and over the 180 degree window from minus 55 to plus 125 that is most of the 1.7 millivolt envelope. A channel that calibrates once at 25 degrees and then runs hot sees the offset move by more than a millivolt, which matters on a 10 millivolt bridge and does not matter on a 2 volt sensor span. The long term stability row is 0.4 microvolts per month, which is smaller than the temperature term by an order of magnitude.
Two megahertz at a gain of twenty five
The 3 dB bandwidth of INA331IDGKR is 2 MHz at a gain of 25, with a slew rate of 5 volts per microsecond, which is a wide front end for a part that draws under half a milliamp. Bandwidth falls as the gain rises, so the same part at a gain of 1000 is a few kilohertz wide, and the settling time grows with gain in the way a single pole amplifier always does.
The wide band matters in front of a sampling converter: the amplifier has to settle after the sampling capacitor is switched in, and a part that is 2 MHz wide at a gain of 25 settles inside the acquisition window of a converter running at a few hundred kilo-samples per second. It also matters for the output swing row. The output reaches the rail only at a gain of 10 or above, so a unity gain buffer built from this part stops 20 millivolts short of each rail, and a 12 bit converter with a 4.096 volt reference has a 1 millivolt bit, which leaves 20 codes unused at each end.
Ninety four decibels at DC, and fifty at forty five kilohertz
The common mode rejection of INA331IDGKR is 90 dB minimum and 94 dB typical at a 5 volt supply over an input window of 0.55 to 3.8 volts, and the family description keeps 50 dB of rejection up to 45 kHz. On a 2.7 volt supply the window narrows to 0.35 to 1.5 volts and the rejection holds at 94 dB.
The 45 kHz figure is the one that decides a real installation. A front end that sits next to a switching supply sees its common mode at the switching frequency, not at DC, and 50 dB turns a 1 volt common mode into 3 millivolts at the input. That is larger than the offset of either grade, so a channel on a noisy rail is limited by rejection rather than by the offset sort. The cure is an input filter ahead of the part, and the input impedance of 10 to the 13 ohms in parallel with 3 picofarads means a 1 kilo-ohm series resistor adds a pole without loading the source.
Where a low power CMOS instrumentation amplifier fits
INA331IDGKR fits a bridge or RTD channel in a handheld instrument, a thermocouple front end with a cold junction compensation network, a physiological amplifier for ECG or EMG where the 0.5 picoamp bias current keeps the electrode offset small, a differential line receiver with gain, and a field meter that has to run from a 3 volt rail for a season.
It stops at four things. The supply floor is 2.7 volts, so a single alkaline cell needs a boost converter. The minimum gain is 5, so a unity gain buffer is a different part. The offset class is hundreds of microvolts, so a load cell or a shunt channel needs a chopper stabilised front end instead. And the common mode window is 0.55 to 3.8 volts on a 5 volt rail, which rules out a high side sense on a 24 volt bus. Our amplifier cross reference page covers the parts that trade quiescent current for offset, and the BOM scrubbing page covers the gain network check against the bill of materials.
Where the grade is bought for the offset, the package and the pinout do not change. Our amplifier cross reference page covers the family, and the vendor consolidation page covers holding one grade rather than two on the line.
Can the A grade drop into this footprint? Yes, same body and pinout, and the offset window widens by a factor of two. A released board that swaps the grade has to recheck its calibration step.
How much of the offset is drift? 5 microvolts per degree over 180 degrees is 900 microvolts, which is most of the gap between the 500 microvolt room temperature figure and the 1.7 millivolt envelope.