Product Specifications
CD4017BM96
Texas Instruments — Power Management & Signal Chain
Product Overview
The CD4017BM96 from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
CD4017BM96: the decade counter on a 2500 piece reel
CD4017BM96 is the tape and reel member of the CD4017B family, a five stage Johnson counter with ten decoded outputs in a 16-lead SOIC, 2500 pieces on a large reel. The vendor descriptor reads CMOS Decade Counter with 10 Decoded Outputs, the document is the CD4017B and CD4022B data sheet revision C, and the feature line gives 10 MHz typical counting at 10 V, fully static operation, a Schmitt trigger clock input, a quiescent current tested to maximum at 20 V on every unit, and 5 V, 10 V and 15 V parametric ratings.
The addendum lists CD4017BM96 as Active in production, SOIC (D) with 16 leads, 2500 pieces on a large tape and reel, RoHS yes with a nickel-palladium-gold finish, moisture sensitivity level 1 at a 260 degree peak, minus 55 to plus 125 degrees, and the marking CD4017B. The tube member of the same body, CD4017BM, is Obsolete with a blank quantity, so the reel is the only active SOIC format; the SOP row CD4017BNSR is Active at 2000 pieces and the TSSOP row CD4017BPWR is Active at 2000 pieces with the marking CM017B.
The CD4017BM96 row as the vendor addendum publishes it
| Part class | Decade counter, five stage Johnson, ten decoded outputs |
| Vendor descriptor | CMOS Decade Counter with 10 Decoded Outputs |
| Vendor document | CD4017B and CD4022B data sheet revision C |
| Counting rate, vendor feature line | 10 MHz typical at 10 V |
| Operation | Fully static, clock can be stopped indefinitely |
| Clock input | Schmitt trigger, unlimited rise and fall times |
| Outputs | Ten decoded, plus a carry out every ten clocks |
| Supply range | 3 V to 18 V |
| Output type | Push pull, balanced outputs |
| Package for this code | SOIC (D), 16 leads |
| Packing | 2500 pieces on a large tape and reel |
| Lead finish | NIPDAU |
| Moisture level | Level 1, 260 degrees peak, unlimited floor life |
| Operating range | Minus 55 to plus 125 degrees |
| Status | Active, production |
| Part marking | CD4017B |
| Reel rows in the addendum | CD4017BM96, CD4017BM96.A and CD4017BM96G4, all 2500 pieces |
| Tube member of the same body | CD4017BM, Obsolete, quantity blank |
| PDIP row | CD4017BE, Active, 25 piece tube |
| SOP row | CD4017BNSR, 2000 piece reel |
| TSSOP rows | CD4017BPW Obsolete, CD4017BPWR Active at 2000 pieces |
The obsolete tube code and the reel that replaced it
The addendum tells a clear story on this family: the SOIC tube row is obsolete, the reel row is active, and the TSSOP tube row is obsolete against an active reel. A board built around the tube code and still carrying it in its bill of materials has to move to the reel code when the stock runs out, and because the die and the body are identical the change is a packing change rather than a qualification change. The only work is on the line, where a feeder has to be loaded instead of a tube.
For a repair or a small build the PDIP row remains active at 25 pieces, which is the practical answer when only a handful of boards are in scope. For a production build the reel is the format that keeps the machine loaded, and a 2500 piece reel covers 2500 single digit counters or 1250 two digit counters.
Counting, decoding and the one hot output
Each of the ten outputs is high for one full clock period, and the sequence is guaranteed by the anti lock gating inside the part, so the counter cannot settle in an unused state the way a counter built from separate flip-flops can. The Schmitt trigger on the clock input allows an unlimited rise and fall time, which means a slow oscillator built from a 4069 inverter, a resistive sensor or a long cable can drive the clock directly without a shaping stage.
The carry out pulses once per ten clocks and is intended to drive the clock of the next package. Because it is a full CMOS output, it can drive a Schmitt input directly, and because the next package also shapes its clock, the chain does not accumulate edge noise. Three packages chain into a count of a thousand without a single external gate.
Static operation and the quiescent current that follows
The body size decides which of the three reels a board takes. The SOIC is the widest of the surface mount options at 16 leads, the SOP is narrower on the same 1.27 mm pitch, and the TSSOP is the smallest of the three at 0.65 mm pitch. A board that has the room takes the SOIC because it is the easiest to inspect, a board that is short of width takes the SOP without changing the pitch, and a board that is short of both takes the TSSOP and accepts the finer inspection requirement.
The part is fully static, which means it draws only leakage when the clock is stopped. The quiescent current is tested to maximum at 20 V on every unit rather than sampled, so a board that sits with the counter frozen at one output draws a current that is specified rather than typical. On a battery powered product that matters, because a counter held at one step is a cheaper way to remember a position than a microcontroller in a low power mode.
The input leakage is the second static number. At 25 degrees the maximum is 100 nA and over the full range it is 1 microamp, so a 100 k pull on the reset pin drops 0.1 V at the top of the range and holds the pin low, while a 1 megohm pull drops 1 V and starts to sit inside the threshold window at a 3.3 V rail. The pull resistor choice is therefore a temperature decision, not a room temperature one.
Where this code sits in the family and in the wider catalogue
The family runs PDIP, SOIC, SOP and TSSOP, and only two of those formats are active at a production quantity: the SOIC reel at 2500 and the SOP reel at 2000, with the TSSOP reel at 2000 as the narrow body option. The ceramic CDIP rows carry screening for the high reliability route. The CD4022B shares the document and gives eight decoded outputs from four stages, which is the right part when the sequence length is eight rather than ten.
The CD4026B replaces the ten decoded outputs with a seven segment decoder, which is the right choice for a numeric display, and the CD4029B gives a presettable up and down counter with binary or BCD counting. A board that needs more than ten steps takes the 4029B or chains two 4017 packages; a board that needs a display takes the 4026B.
Incoming checks on a reel of counters
The label should read CD4017BM96 at 2500 pieces, and the body marking reads CD4017B rather than the full string, which is expected on this die. The functional check from the first pocket should clock ten steps, verify that each output goes high once, and confirm that the carry out pulses on the tenth clock. The reset check should follow, because a counter that steps correctly can still ignore reset and fail at power up on the board.
The reference pages are the incoming inspection plan, date code management, and the BOM scrubbing route when a bill of materials still carries the obsolete tube code.
Questions that come up on the reel counter
Whether the obsolete tube code can be substituted by the reel code. It can, because the die and the body are the same, and the change is limited to packing and to the line setup.
Whether the counter can drive a relay coil. It cannot, and the output needs a transistor with a suppression diode across the coil.
Whether the outputs can be paralleled for more current. They cannot be paralleled without risk, because only one output is high at a time and two outputs shorted together would fight when the sequence moves.
Whether a 4017 can replace a 4022. Not directly, because the 4022 has eight decoded outputs and a different sequence length, and the two are the same die with different decode gating.