Contact Us

BQ28Z610DRZR

Brand: Texas Instruments
Texas Instruments BQ28Z610DRZR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

BQ28Z610DRZR — Power Management & Signal Chain | Superb Automation

BQ28Z610DRZR

Texas Instruments — Power Management & Signal Chain

Product Overview

The BQ28Z610DRZR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

BQ28Z610DRZR fuel gauge and protection for one and two cell packs

The BQ28Z610DRZR is a single chip that measures the state of charge of a one cell or two cell lithium pack and protects that pack at the same time. It runs the Impedance Track algorithm on an internal processor, keeps the model in flash, and reports through an I2C bus at up to 400 kHz. Because the same device also drives the charge and discharge FETs, a pack built around it does not need a separate protector board next to the gauge.

The part is aimed at packs that must report remaining capacity honestly over the whole life of the cells, not only at a fresh state. Tablets, wireless speakers, portable medical handhelds and wearable health devices are the applications named in the vendor document. For a buyer, the useful point is that the gauge, the protection thresholds and the authentication responder all sit in one 12 pin VSON body measuring 4.0 mm by 2.5 mm, which keeps the pack PCB small and the test plan short.

Key parameters taken from the BQ28Z610DRZR document

Functionfuel gauge plus primary protection for 1-series to 2-series lithium packs
PackageVSON-12, body 4.0 mm by 2.5 mm
Supply range2.2 V to 26 V on the VC2 and PBI pins
Coulomb counter offsetbelow 1 uV typical
Sense resistor1 mOhm to 10 mOhm, with 1 mA of current resolution
Cell voltage sample interval250 ms
BusI2C at up to 400 kHz, master mode broadcast plus slave access
AuthenticationSHA-1 responder, plus battery trip point for Windows hosts
Pack FET drivehigh side N-channel CHG and DSG, charge pump driven
Cell balancinginternal bypass path per cell
Shutdown supply current0.5 uA typical, 2 uA maximum
Example thresholds in the vendor procedureCOV 4300 mV, CUV 2500 mV, OCC and OCD 6000 mA, safety overvoltage 4500 mV, shutdown 2300 mV

The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.

Where the numbers matter in a real build

The thresholds in the last row are examples from the vendor procedure for a 2s1p pack with a 4400 mAh capacity. They are not fixed values. The data flash is programmed per project, so the first article has to be checked against the cell supplier's charge and discharge limits rather than against the table above.

The current path is the part that most often gets under specified. A 1 mOhm sense resistor gives the finest resolution, 1 mA, but the voltage across it at 6 A is only 6 mV, so the copper and the Kelvin connection have to be treated as part of the measurement. A 10 mOhm resistor makes the sense easy and burns 360 mW at 6 A. The right choice sits between those two and follows the maximum pack current, not habit.

Master mode I2C is the feature that changes the firmware budget. The gauge itself broadcasts charging voltage and current to the charger, so the host does not have to poll capacity and then write charger registers in a loop. On a small product that removes a task from the MCU and removes a class of bug where the host stops updating the charger after a sleep event. The charger on the other side must accept those broadcast commands, which is a selection point rather than an afterthought.

Protection is layered. The primary thresholds trip the FETs, and a separate safety overvoltage setting can put the pack into a permanent fail state when a cell keeps climbing past the primary limit. For medical and asset tracking products, that second layer is usually what the safety reviewer asks about, and it is worth writing the delay values into the test plan at the same time as the thresholds.

  • Two independent ADCs sample current and voltage at the same instant, so a load step does not show up as a false capacity jump.
  • The SHA-1 responder lets the host refuse a pack that was not built by the approved line, which matters for warranty and for battery safety claims.
  • Cell balancing is an internal bypass, so no external bleed resistors are needed, but the balance current is small and only useful for matched cells.
  • The pack can be woken and read on the bench with the vendor tool before it is sealed, which is the cheapest moment to catch a wrong chemistry ID.

Which projects this part fits

Any 1s or 2s pack that has to report capacity to a host and cut off on its own fits this part: tablet and speaker packs, handheld medical monitors, wearable health patches, portable instruments and battery backup modules. Buyers who move a pack from a discrete protector plus a separate gauge usually do it to save board area and test time. Our power management cross reference lists the parts we hold against this family, and the medical device component page covers the traceability that hospitals and notified bodies ask for.

Ordering, flash image and what the first article has to prove

The BQ28Z610DRZR arrives as a programmed part, not as a blank one. The pack maker writes the data flash image with the vendor tool, and from that moment the chemistry, the cell count, the protection thresholds and the sense resistor value are part of the delivered function. Two reels of the same order code can therefore carry different behaviour if the programming house used a different image, so the image revision belongs in the incoming record next to the date code.

The body in the current addendum is the 12 pin VSON, 4.0 mm by 2.5 mm. The older gauge generation in the same family uses a different pin count and a different pinout, so a pack that swaps generations has to change its board rather than its firmware. When a customer asks for a drop in replacement, the footprint comparison comes before any discussion of registers.

First article checkWhat it proves
Device type and firmware version read back over I2CThe image on the reel is the image the pack was qualified with
Sense resistor value in data flash against the fitted shuntCurrent and capacity are scaled correctly before any cycle is run
COV, CUV and safety overvoltage thresholds against the cell datasheetThe protection layer matches the cell being shipped, not a template
SHA-1 key exchange with the hostAn unapproved pack is refused by the product
One full charge and discharge cycleThe capacity model has a starting point before the pack leaves the factory

The cycle in the last row is the one step that is often dropped. A pack shipped with an unseeded model reports a capacity that is wrong by a few percent for the first weeks, and the field sees it as a battery problem rather than a commissioning gap.

Questions that come up before a purchase order is released

Can this device protect a two cell pack on its own?

Yes. The part is specified for one and two series cells, drives both pack FETs from a high side charge pump, and carries the primary overvoltage, undervoltage, overcurrent and short circuit thresholds in data flash. A second level protector is still added by some pack makers, but it is a policy choice rather than a requirement of the chip.

How is the pack configured if there is no firmware team on the project?

Configuration is written to data flash with the vendor tool over the same I2C bus. The pack maker sets chemistry, capacity in mAh, cell configuration, protection thresholds and the permanent fail settings once, then locks the parameters. The host only reads standard registers afterwards, so an MCU with a basic I2C driver is enough.

What happens if the sense resistor is not 1 mOhm?

The current scale in data flash is set to the resistor actually fitted, in the range 1 mOhm to 10 mOhm. If the value is left at the default, every current and capacity number is scaled wrong and the error only shows up after a full charge and discharge cycle, which is why the calibration step belongs in the first article test.

How SUPERB handles this line

We supply the BQ28Z610DRZR as a tape and reel line item with date code and lot traceability, and we can hold a small buffer for packs that are already in certification. If the pack is moving from a discrete protector, send the current BOM and the cell specification and we will check the thresholds against the cell datasheet before anything is ordered. Start from the BOM shortage recovery page if the line is already short.