Contact Us

AD8603AUJZ

Brand: Analog Devices
Analog Devices AD8603AUJZ is a analog & mixed-signal component designed for Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AD8603AUJZ — Analog & Mixed-Signal ICs | Superb Automation

AD8603AUJZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD8603AUJZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD8603AUJZ: single micropower amplifier with 50 microvolts offset at 40 microamps

The AD8603AUJZ is a single CMOS rail-to-rail amplifier in a 5-lead TSOT-23 that combines a 50 uV maximum offset, a 1 pA maximum input bias current and 40 uA of supply current with operation from 1.8 V. It is the part for a battery instrument that has to measure a small DC signal accurately while spending less than a hundred microamps on the whole front end.

Published values

ParameterValue
Offset voltage12 uV typical, 50 uV maximum
Offset voltage drift1 uV/C typical, 4.5 uV/C maximum
Input bias current0.2 pA typical, 1 pA maximum
Input voltage range0.3 V beyond both rails, -0.3 V to 5.2 V on a 5 V supply
Supply current per amplifier40 uA typical, 50 uA maximum
Gain bandwidth400 kHz at 5 V, 385 kHz at 1.8 V
Slew rate0.1 V/us
Voltage noise density25 nV/root Hz at 1 kHz
Settling to 0.1%23 us on a 2 V step at unity gain
CMRR and PSRR80 dB minimum, 98 to 100 dB typical
Short circuit currentplus or minus 70 mA at 5 V
Supply range1.8 V to 5 V single supply

One hundred millivolts per microsecond is the real limit

0.1 V/us of slew rate sounds like a small number until it is turned into time: a 2 V step needs 20 us before the output has moved, and the published settling to 0.1 percent is 23 us. A 16 channel scanner built on this part therefore runs at about 40 kSPS aggregate, not the 400 kHz of bandwidth would suggest. Where a channel has to switch quickly, this is the wrong amplifier and the 8 MHz class part costs twenty times the current for twenty times the speed.

Input range beyond the rails, and why that matters

The input works from 0.3 V below the negative rail to 0.3 V above the positive one on a 5 V supply, which is unusual at this current level. In practice it means a sensor powered from the same rail as the amplifier can sit at the rail and still be measured, and a signal that overshoots the rail does not immediately forward bias the input protection. It does not mean the part can measure a negative voltage in a single supply system: the output still cannot go below ground.

The noise and the source impedance decide together

Twenty-five nanovolts per root hertz is high for a precision part and low enough for a bridge. A 10 kOhm source resistor contributes about 13 nV/root Hz of thermal noise at room temperature, so the amplifier's contribution in quadrature is 28 nV, only twice the resistor alone. A 1 kOhm source contributes 4 nV and the amplifier dominates completely. This is why the part is paired with high impedance sensors and rarely with low impedance ones.

Where 1.8 V operation earns its place

Two lithium cells in series, or a single cell with a boost converter set to 1.8 V, are enough to run this amplifier, and the offset and drift do not degrade at that rail the way the bandwidth does. A gas sensor, a thermopile or an electrochemical cell that produces tens of millivolts can therefore be conditioned without a second rail and without a calibration step in production.

Buyers usually arrive at medical device components to find the family alternatives, then use the amplifier cross reference to confirm a substitute before it is fitted; component lead time solutions is the routine for a part that has already stopped shipping.

Two questions buyers ask

Can the AD8603AUJZ run directly from a 1.8 V logic rail? Yes, the minimum supply is 1.8 V, and the input range extends 0.3 V beyond both rails at that supply, so a 1.8 V sensor output can be buffered without a headroom problem.

How does it compare with the AD8607 in the same family? The AD8607 is the two channel version of the same amplifier and the AD8609 is the four channel one. The electrical figures are shared, so the choice is channel count and package.