Contact Us

AMC1311DWVR

Brand: Texas Instruments
Texas Instruments AMC1311DWVR is a power management component designed for AI Servers & Low-Altitude Economy (Drone and UAV) and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

AMC1311DWVR — Power Management & Signal Chain | Superb Automation

AMC1311DWVR

Texas Instruments — Power Management & Signal Chain

Product Overview

The AMC1311DWVR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-efficiency power conversion with low quiescent current
  • Wide input voltage range with precision output regulation
  • Integrated over-current, over-temperature, and short-circuit protection
  • Small footprint packaging for space-constrained designs
  • AEC-Q100 qualified options available for automotive applications
  • Flexible sequencing and soft-start control

Key Specifications

Input VoltageV
Output VoltageV
Output CurrentA
Switching FrequencykHz
Efficiency%
Quiescent CurrentµA
Topology—
Package—
Operating Temp°C
Protection—

Applications

Industrial Automation Automotive Electronics Telecom Infrastructure Server & Data Center Power Medical Devices Consumer Electronics

Request Quote — In Stock, 100% New & Original, Full Warranty

AMC1311DWVR high impedance 2 V input isolated amplifier in the eight pin DWV body

The AMC1311DWVR is the reinforced isolated amplifier from the AMC1311 line, built for isolated voltage measurement rather than for current shunt work. The input is a high impedance node with a 2 V linear range and a fixed gain of one, so a resistive divider from a high voltage rail can be connected directly to the input pins without an op amp buffer in front of it. The output is differential, centred at 1.44 V, and couples to a differential input converter on the low side.

The part exists because the two jobs in an isolated measurement chain are not the same. A shunt signal is a few tens of millivolts from a low impedance source, and the amplifier for that job needs a small input range and a large gain. A bus voltage after a divider is a volt or two from a source that cannot drive any load, and the amplifier for that job needs a very high input resistance, a gain of one and a large signal swing. The AMC1311 is the second kind, and using it in front of a divider means the divider resistors can be sized for voltage standoff instead of for loading.

Key parameters taken from the AMC1311DWVR document

Input range0 V to 2 V linear, tolerant to minus 0.1 V at the bottom, with a fixed gain of 1 V/V
Input resistance1 gigohm typical at 25 C, so a divider in the megohm range is not loaded
Input bias current15 nA maximum, which is the number that decides the divider error budget
Offset errorPlus or minus 9.9 mV maximum on the AMC1311, plus or minus 1.5 mV on the AMC1311B
Offset driftPlus or minus 20 microvolt per C typical on the AMC1311, 10 maximum on the B grade
Gain errorPlus or minus 1 percent maximum on the AMC1311, plus or minus 0.2 percent on the B grade
Nonlinearity0.04 percent maximum on the AMC1311, 0.01 percent typical on the B grade
Noise and distortionSignal to noise 82.6 dB, total harmonic distortion minus 87 dB, output noise 220 microvolt RMS over a 100 kHz window
Bandwidth220 kHz typical on the AMC1311, 275 kHz on the AMC1311B
Output common mode1.44 V typical with a 1.39 to 1.49 V window, differential clipping at 2.49 V
Failsafe outputMinus 2.5 V differential when the high side rail is missing or the shutdown pin is high
Common mode transient immunity15 kV per microsecond minimum on the AMC1311, 100 kV per microsecond on the B grade
SuppliesHigh side 4.5 to 5.5 V on the AMC1311 and 3.0 to 5.5 V on the B grade, low side 3.0 to 5.5 V
Isolation5000 V RMS for one minute per UL1577, 7000 V peak reinforced per VDE 0884-17, working voltage 1500 V RMS
TemperatureMinus 40 to plus 125 C on the AMC1311, minus 55 to plus 125 C on the B grade
Order code factsAMC1311DWVR, SOIC DWV eight pins, 1000 pieces on a large reel, moisture level 3 with a 168 hour floor life, marking 1311

The table above is read from the vendor document, not from a distributor summary. Where a window is printed, the window is what a production test should use, and the typical value is only a starting point for the first article.

Where the numbers matter in a real build

The failsafe output is the feature that separates this part from a general purpose isolation amplifier, and it is worth wiring the converter to expect it. When the high side rail collapses or the shutdown pin is pulled high, the differential output goes to minus 2.5 V instead of drifting to an undefined level. A converter with a minus 2.5 V input window reads that as a full scale negative code, which firmware can treat as a diagnostic rather than as a real measurement. On a motor drive this is the difference between a controller that reports a missing gate driver supply and one that regulates against a divider that is no longer powered.

The choice between the plain part and the B grade is a choice about where the error budget sits. At 25 C the plain part carries plus or minus 9.9 mV of offset on a 2 V range, which is half a percent of full scale before any divider tolerance is added. The B grade carries 1.5 mV, and its drift is half as large again. On a 400 V bus measured through a 200 to 1 divider, 9.9 mV of input offset is close to 2 V on the bus, which matters for a protection threshold but not for a monitoring channel. The B grade also runs its high side from 3.3 V, which the plain part does not allow.

Common mode transient immunity is the specification that gets ignored until a silicon carbide stage is switched on. The plain part is specified at 15 kV per microsecond minimum, the B grade at 100. In a converter with a fast dv/dt node next to the divider, the isolation barrier sees that edge as a common mode step, and a slow amplifier produces an output glitch that the control loop reads as a current or voltage transient. If the board is switching at 20 kV per microsecond or faster, the plain part is not the right choice, and the divider, the barrier and the converter input filter all have to be looked at together.

The eight pin DWV body carries the isolation rating, and the creepage and clearance belong to that body alone. A substitution into a narrower body changes the numbers in the safety file, so a second source has to be checked on the package drawing and not only on the electrical table. The same warning applies to the two grades: both ship in DWV, both are pin compatible, and the difference is in the internal grade marking, which is 1311 on one and 1311B on the other. We check that marking on incoming reels because the two parts are otherwise indistinguishable in a tray.

  • Divider error against the input bias current, with the divider impedance at the top of its tolerance.
  • Offset at 25 C on the first article, measured with the input shorted to the high side ground.
  • Output behaviour with the high side rail removed, to confirm the converter reads the failsafe level.
  • Transient response at the switching edge of the power stage, with the real dv/dt on the board.
  • Isolation test on the barrier, at the working voltage the safety file claims rather than at the rated peak.
  • Marking check on the reel, since the plain grade and the B grade share a body and a pinout.

Which projects this part fits

This part fits DC bus voltage sensing in motor drives and frequency inverters, DC link monitoring in solar and wind converters, battery stack voltage measurement in energy storage, isolated supply monitoring in medical equipment and rail traction auxiliary supplies. It is the natural selection where a divider has to feed a measurement channel with no buffer, where the source impedance is high, and where a missing high side supply has to be visible to the controller. For customers building inverters around silicon carbide or gallium nitride devices, the B grade is the part to quote, because the plain grade does not carry the transient immunity those stages demand.

Questions that come up before a purchase order is released

Can the divider be connected directly to the input pins?

Yes, that is what the high impedance input is for, with one condition. The divider impedance has to be low enough that the 15 nA of input bias current does not shift the reading beyond the tolerance the channel needs, and the divider has to be built from resistors that hold their ratio over the voltage and the temperature the board sees. A 2 megohm divider with 15 nA flowing through it moves by 30 mV, which is fifteen times the offset of the B grade.

What does the minus 2.5 V failsafe level mean for the converter?

It means the converter has to have a negative input range, or a level shift, to read the diagnostic. If the converter clips at zero, the missing supply looks the same as a zero voltage reading, which is the worst possible outcome for a protection channel. Many customers pair this part with a differential converter that has a plus or minus 2.5 V window precisely so the failsafe code is visible.

Is the AMC1311 a replacement for the AMC1301?

No. The AMC1301 is the shunt part with a small input range and a gain above one, and the AMC1311 is the voltage part with a 2 V input and a gain of one. They share a body and an isolation barrier, which is why the confusion happens, but the input stage and the scaling are different. Putting the voltage part across a shunt gives a reading that is too small by the ratio of the two gains.

How is the part tested at incoming inspection?

The barrier is the only thing that cannot be checked with a multimeter, so the practical plan is a supply current check on both sides, an offset check with the input grounded, and a functional check through the isolation barrier with a known input and a converter on the low side. A barrier defect shows up as a supply current that is out of family or as a channel that reads zero regardless of input, and both are visible without a high voltage test set.

What changes when the B grade is used at 3.3 V on the high side?

The isolation rating and the pinout stay the same, the input range stays the same, and the transient immunity improves. The supply current falls with the lower rail, and the output swing is unchanged because the output stage sits on the low side rail. The one thing to recheck is the divider, because the top of the input range does not move when the high side rail moves, so a divider built for a 5 V rail has the same ratio at 3.3 V.

How SUPERB handles this line

We supply the AMC1311DWVR and the B grade from original reels with lot traceability, and we check the grade marking before the parts reach a line, because the two grades share a body. The power management cross reference page lists the isolated measurement families we carry together with the converter side, the ADC and DAC cross reference page covers the differential converters that read this output, and pin to pin cross reference is the page to start from when a board has to move between grades without a respin.