Product Specifications

AD603ARZ — Analog & Mixed-Signal ICs | Superb Automation

AD603ARZ

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The AD603ARZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

AD603ARZ: 25 mV per dB and the 40 dB One Control Voltage Can Span

The AD603ARZ is a variable gain amplifier whose gain is linear in decibels rather than in volts, and that property is what makes it usable inside an automatic gain control loop. The control scaling is 25 mV per dB, so a 1 V control swing covers 40 dB, which is the central range of the part regardless of which pin strapped range is selected. Three ranges are available by strapping: minus 11 dB to plus 31 dB with 90 MHz of bandwidth, plus 9 dB to plus 51 dB with 9 MHz, or an intermediate pair such as minus 1 dB to plus 41 dB with 30 MHz using one external resistor. The part adds 1 dB of overrange and underrange beyond the stated window so the loop does not sit against a hard stop. Input noise is 1.3 nV per root hertz and the gain control response for a 40 dB step is under 1 microsecond.

Published values

ParameterValue
Gain lawLinear in dB, 25 mV per dB
Control span1 V covers the central 40 dB
Range option oneMinus 11 dB to plus 31 dB, 90 MHz
Range option twoPlus 9 dB to plus 51 dB, 9 MHz
Intermediate rangeMinus 1 dB to plus 41 dB, 30 MHz with one resistor
Overrange and underrange1 dB beyond the selected window
Input noise1.3 nV per root hertz
Control inputDifferential, 50 megohm, 200 nA bias
Control responseUnder 1 microsecond for a 40 dB change
Load drive100 ohm with low distortion, 500 ohm in shunt with 5 pF specified
Attenuator step6.021 dB between tap points
Body8-lead surface mount, R suffix

The attenuator ahead of the amplifier is the point

Inside the part a precision passive attenuator sits in front of a fixed gain stage, and the control voltage interpolates between attenuator taps. Because the input is attenuated before it reaches the amplifier, the amplifier never has to survive a full scale input at maximum gain, which is what allows one fixed gain block to hold both the noise figure at low gain settings and the distortion figure at high ones. The tap spacing is 6.021 dB and the interpolation between taps is what keeps the gain law smooth rather than stepped. For a loop filter this means the small signal slope really is 25 mV per dB across the window, so the loop settles without the stair stepping that shows up in switched attenuator front ends.

Where a dB linear part changes the loop arithmetic

An AGC loop built around an amplifier that is linear in volts needs a multiplier or a log detector to keep the loop gain constant, because the loop gain itself changes with the gain setting. With a dB linear part the control voltage is already logarithmic, so a peak detector and an integrator are enough and the loop bandwidth stays roughly constant across 40 dB. That simplification is the reason this family survives in receivers that are otherwise fully digitised: the analog loop still does the fast attack work while the digital side handles the slow correction. The trade is that the control input has to be quiet, since 25 mV per dB means 250 microvolts of control noise is 0.01 dB of gain modulation, which appears as amplitude noise on the signal.

Sourcing the strapped range you actually need

All three range options come from the same die and differ only in how two pins are strapped, so the order code does not encode the range. That is worth stating plainly, because a buyer comparing two line items with the same part number is not comparing two behaviours. What the order code does encode is the body and the grade, and the R suffix is the narrow surface mount body. The amplifier cross reference lists the dB linear parts we can supply against this one, the pin to pin cross reference covers the footprint question when a second source is being considered, and the ADI second source page covers grade equivalence inside the family.