Contact Us

VBP165R11S

Brand: VBsemi
VBsemi VBP165R11S is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

VBP165R11S — Discrete & Power Semiconductors | Superb Automation

VBP165R11S

VBsemi — Discrete & Power Semiconductors

Product Overview

The VBP165R11S from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

VBP165R11S: 650 V super junction in TO-247AC

The VBP165R11S is an N channel super junction MOSFET in the TO-247AC body, printed at 650 V drain to source with a 700 V breakdown at the maximum junction temperature, plus or minus 30 V on the gate. On resistance is 0.42 ohm at a 10 V gate, current is 11 A at a 25 C case and 9.7 A at 100 C, and the single pulse avalanche energy is 132 mJ. The vendor lists server and telecom power supplies, switch mode supplies, power factor correction, lighting including high intensity discharge and fluorescent ballast, and industrial use.

The TO-247 body is the through hole body for a heatsink bolted switch, and it gives a 0.6 C per watt junction to case path with a 60 C per watt junction to ambient figure. The 11 A rating therefore means 11 A on a heatsink, not in free air, and the 83 W dissipation is what a TO-247 on a modest heatsink can remove. The part is the standard choice for a 400 V bus power factor correction stage from a few hundred watts to about 2 kW.

The full ratings table

Drain to source voltage650 V, 700 V at maximum junction temperature
Gate to source voltageplus or minus 30 V
On resistance at 10 V gate0.42 ohm at 5 A
Continuous drain current11 A at 25 C case, 9.7 A at 100 C case
Pulsed drain current55 A
Single pulse avalanche energy132 mJ, 4.5 A into 28.2 mH
Power dissipation83 W
Linear derating factor1.67 W per C at 25 C, 1.5 at 100 C, 0.3 at 150 C
Junction to case0.6 C per watt maximum
Junction to ambient60 C per watt maximum
Gate threshold voltage2 V minimum, 4 V maximum
Total gate charge38 nC typical, 56 nC maximum
Input capacitance680 pF
Output capacitance at 100 V140 pF
Body diode forward voltage1.5 V maximum at 5 A
Body diode reverse recovery270 ns, 3.3 microcoulomb, 30 A peak

Reading a high voltage part correctly

The breakdown row is 650 V at 25 C and 700 V at the maximum junction temperature, with a 0.65 V per C coefficient. That is the opposite direction from most parameters and it is good news: the voltage margin grows as the part heats. A 400 V bus with a 10 per cent surge reaches 440 V, and a 650 V part has 210 V of headroom at 25 C and more when hot, which is why this class is the default for a single phase power factor correction stage.

The on resistance is measured at 5 A, less than half the rating, and the loss at 5 A is 10.5 W on the cold figure. At 100 C the resistance will be higher, perhaps 0.6 ohm, which is 15 W at 5 A and 24 W at 8 A. That is a real heatsink, and it is why a 650 V part in a 1 kW stage is chosen with the thermal path in mind rather than the current rating. The gate charge is low at 38 nC typical and 56 nC maximum with 680 pF of input capacitance and only 5 pF of reverse transfer, which makes the part easy to drive and keeps the switching loss down at 65 kHz to 100 kHz, the usual range for a continuous conduction power factor correction stage.

The diode is the weak number: 270 ns recovery, 3.3 microcoulomb of recovered charge and a 30 A peak reverse current at 5 A forward with 100 A per microsecond. In a continuous conduction boost the diode is not the switch body diode but an external silicon carbide or ultrafast part, so the body diode recovery matters mainly during start up and during a transient. In a bridgeless or a totem pole stage the body diode does conduct, and 270 ns is slow, which is why this die suits a classic boost rather than a totem pole arrangement.

The output capacitance of 140 pF at 100 V and 5 pF of reverse transfer give fast edges and a drain node that rings. At 650 V the ringing can exceed the rating if the loop inductance is not controlled, and the 132 mJ avalanche rating absorbs only a limited amount of that energy. A snubber or a ferrite bead on the drain is common in this class, and the gate resistor should be chosen from the measured edge rather than from the reference value, since a 5 pF feedback capacitance gives very little damping on its own.

Where a 650 V TO-247 part is used

Power factor correction in a 400 V bus is the main application, from a 300 W adapter to a 2 kW server supply, where the part runs at 65 kHz and carries 3 A to 8 A. Telecom rectifiers use the same position, and industrial power supplies with a wide input range use it for the same reason. Lighting uses it in the ballast of a high intensity discharge lamp, where the avalanche rating absorbs the strike, and in fluorescent ballast where the 650 V rating covers the lamp transient.

Server and telecom supplies also use this part in the start up and standby path, where a high voltage switch has to hold off the bus and conduct a small current. In every case the TO-247 body allows a heatsink, and the 83 W dissipation is what a 20 C per watt heatsink turns into a 4 C case rise at 20 W.

Sourcing 650 V parts and the gate network

The 650 V class is crowded, and the differences between parts are in the recovery and the dvdt behaviour more than in the resistance. Our pin to pin cross reference compares the TO-247 pinout, the isolation pad requirement, the gate charge and the diode recovery before anything is quoted, because a part that fits the hole can still change the switching loss by 30 per cent.

Where a lead time forces an alternative, component lead time solutions starts from the switching cell rather than the part number: the gate resistor, the snubber and the boost diode are quoted with the switch, because a different gate charge needs a different resistor. For a replacement on a qualified product the test route is in how to verify a drop in replacement, and for 650 V it includes a full load thermal soak and a diode recovery measurement at the real di/dt.

Questions we answer about this code

Is 11 A continuous? At a 25 C case with a heatsink, yes in principle, but at 11 A the conduction loss on the hot resistance is about 70 W, which is close to the 83 W dissipation and leaves nothing for switching. The practical continuous current on a 20 C per watt heatsink is 4 A to 6 A. The second question is whether the 700 V figure can be used for margin. It is a breakdown at the maximum junction temperature, not a working rating, and the working number is 650 V.

The third is the diode. A 270 ns recovery with 3.3 microcoulomb is slow, and a totem pole stage should not use this die without checking the recovery loss. The fourth is the avalanche rating: 132 mJ into 28.2 mH at 4.5 A covers a lamp strike but not a repetitive event, and the linear derating factor falls from 1.67 W per C at 25 C to 0.3 at 150 C, which is a steep curve that a hot board has to respect.

On supply we quote the reel, the date code and the lot, and we hold a resistance and threshold sample per lot. For a TO-247 part we also ask the customer whether they need an isolation pad and a mounting clip in the same shipment, because a kit that arrives without them stops a line just as effectively as a missing reel.