VBMB165R34SFD
Product Specifications
VBMB165R34SFD
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBMB165R34SFD from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBMB165R34SFD: 650 V and 34 A with 80 milliohm in a TO220F
The VBMB165R34SFD is a single N channel MOSFET in a TO220F body, the isolated version with a plastic tab. Drain to source is 650 V, the gate window is plus or minus 30 V, the threshold is 3.5 V, the printed drain current is 34 A and the on resistance is 80 milliohm at a 10 V gate. The die is SJ multiple epitaxy, the charge balance structure used across this voltage range.
Eighty milliohm at 650 V is a good figure and it is not usable at 34 A. The loss at that current is 92 W, which no plastic tab can remove. At 10 A it is 8 W, at 5 A it is 2 W, at 3 A it is 0.7 W. The working range in this body is 3 to 8 A on a copper island and 10 to 15 A on a bolted heatsink with a thermal pad.
Six hundred and fifty volts is the class for a 400 V DC bus with margin and for a power factor stage on a 230 V AC line. It is not the class for a 480 V AC line after rectification at 680 V, where a 900 V or a 1200 V device is needed, and it is not the class for a 650 V rail that sits at the rating with no headroom.
Key data for the VBMB165R34SFD
| Configuration | Single N channel |
| Package | TO220F, isolated plastic tab |
| VDS | 650 V |
| VGS | Plus or minus 30 V |
| Vth | 3.5 V typical |
| ID | 34 A, a die figure at a 25 C case |
| RDS(on) at 10 V | 80 milliohm |
| Technology | SJ multiple epitaxy |
| Loss at 3 A | 0.7 W |
| Loss at 5 A | 2 W |
| Loss at 10 A | 8 W |
| Loss at 34 A | 92 W |
The plastic tab sets the current, not the die
A metal tab TO220 removes heat through a copper slug about 1 C per watt junction to case. The TO220F puts a plastic layer in that path and the figure rises to 2 or 3 C per watt, so the same die runs 20 to 30 C hotter for the same watts. At 8 W the difference is the gap between a comfortable part and one that trips its own thermal protection on a warm day.
What the plastic buys is simpler assembly. No insulating washer, no grease, no shoulder washer, no torque specification, and no risk of a burr puncturing a pad. Where several devices share one grounded extrusion the saving in assembly time and in field failures is worth more than the degrees. Where the sink can be isolated anyway, the metal tab is the better thermal choice.
The practical rule for this part is to size it from the sink rather than from the table. A 10 by 10 centimetre extrusion at 2 C per watt holds 8 W with the junction 16 C above the sink and leaves margin. A copper island holds 2 to 3 W, which is 5 to 6 A. Nothing above that belongs in a plastic tab without a sink.
Switching at 650 V and the body diode
At 650 V the output capacitance stores energy that is lost at every turn on in a discontinuous converter, and the body diode recovery adds to it. In a power factor stage at 65 kHz the switching term is usually smaller than the conduction term at 5 A but larger at 2 A, which is the point where the frequency starts to decide the loss rather than the resistance.
The body diode of a charge balance die at this voltage is fast but not soft. In a bridge leg, the recovery of the diode in the low side appears as a current spike in the high side at turn on, and the spike rings with the loop inductance. A short dead time with a fast gate, a tight loop and a small RC across the low side diode are the usual control measures.
Gate drive at 650 V has one hazard that does not appear at 40 V. The Miller capacitance couples the drain swing into the gate, and a gate held at zero through a weak resistor can rise above the 3.5 V threshold while the opposite device conducts. A negative bias of 3 to 5 V, or an active pull down in the driver, is the normal protection, and the plus or minus 30 V window leaves room for it.
Where the part fits and where it does not
It fits a 400 V bus at 3 to 8 A, a power factor correction stage below 1 kW, an auxiliary supply on a 230 V line, a half bridge in a small inverter, an active clamp in a flyback and a discharge path on a 400 V capacitor bank. It does not fit a 480 V AC input at 680 V after rectification, a 20 A motor drive, or a converter above 150 kHz at more than 3 A.
Where this part is offered against an existing code, the comparison has to be made on the resistance at the real gate voltage, the recovery of the body diode and the thermal penalty of the isolated tab, because a part that matches the table can still run hotter in the same socket. Our how to verify a drop in replacement page covers the checks that come before a sample is approved.
The sourcing side of this part is covered on the supplier quality audit. For a high voltage line bought from a new source, that page covers what is verified before the first lot is released.
Questions we get on this code
Can it run on a 400 V bus? Yes, with about 250 V of margin for the clamp and the surge, which is the normal rule for this class.
Is 34 A a working current? No. Ninety two watts at that current has no path out of a plastic tab. Five to eight amps on a copper island is realistic.
Why choose this over a metal tab part? Assembly. No washer, no grease, no short risk against a grounded sink. The cost is 20 to 30 C hotter at the same watts.