VBM2104N
Product Specifications
VBM2104N
VBsemi — Discrete & Power Semiconductors
Product Overview
The VBM2104N from VBsemi is a discrete power semiconductor delivering efficient switching and power conversion. VBsemi specializes in discrete MOSFETs, power transistors, and protection devices at competitive cost for power supplies, motor control, and consumer electronics.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
VBM2104N: a minus 100 V P channel part rated to a 175 C junction
The VBM2104N is a P channel trench MOSFET in the TO-220AB body, rated minus 100 V with a plus or minus 20 V gate and a junction range up to 175 C. On resistance is 0.033 ohm at a minus 10 V gate and 0.037 ohm at minus 4.5 V, and continuous drain current is minus 50 A with the case at 25 C and minus 30 A with it at 125 C.
Two things separate this sheet from the rest of the P channel band. The first is the 175 C junction, which is 25 C more headroom than the sibling part and matters in an enclosure that runs warm. The second is that the sheet prints the hot on resistance rows, 0.074 ohm at 125 C and 0.093 ohm at 175 C, where most P channel sheets print one 25 C row and leave the rest to a curve.
Being able to read the hot number off the table changes how a board is quoted. At 20 A the 25 C row gives 13.2 W and the 175 C row gives 37.2 W, a factor of 2.8, and only the second number describes a part that is actually hot.
The parameter table
| Drain to source voltage | minus 100 V |
| Gate to source voltage | plus or minus 20 V |
| On resistance at minus 10 V gate, minus 9.2 A, 25 C | 0.033 ohm |
| On resistance at minus 10 V, minus 9.2 A, 125 C | 0.074 ohm |
| On resistance at minus 10 V, minus 9.2 A, 175 C | 0.093 ohm |
| On resistance at minus 4.5 V gate, minus 7.7 A | 0.037 ohm |
| Gate threshold at 250 microamp | minus 1.0 V to minus 2.5 V |
| Continuous drain current, case at 25 C and 125 C | minus 50 A and minus 30 A |
| Continuous source current, package limited | minus 50 A |
| Pulsed drain current at 300 microsecond | minus 180 A |
| Avalanche current and single pulse energy | minus 44 A and 96 mJ |
| Power dissipation, case at 25 C and 125 C | 136 W and 45 W |
| Junction to case and junction to ambient | 1.1 and 50 C per watt |
| Operating junction and storage range | minus 55 to plus 175 C |
| Gate source leakage at plus or minus 20 V | plus or minus 100 nA |
| Zero gate voltage drain current at minus 100 V, 125 C | 50 microamp |
| Zero gate voltage drain current at minus 100 V, 175 C | 250 microamp |
| Input capacitance, typical and maximum | 4433 and 5545 pF |
| Output and reverse transfer capacitance | 301 and 208 pF typical |
| Total gate charge, typical and maximum | 96 and 144 nC |
| Gate source and gate drain charge | 8.4 and 23.5 nC |
| Gate resistance, minimum, typical and maximum | 1.5, 3.13 and 4.7 ohm |
| Turn on delay and rise time | 11 and 11 ns typical |
| Turn off delay and fall time | 78 and 15 ns typical |
| Body diode forward drop at minus 7.7 A | minus 0.8 V typical, minus 1.5 V maximum |
| Pulsed source drain diode current | minus 150 A |
The hot rows, and what they cost
At 20 A the part dissipates 13.2 W on the 25 C row, 29.6 W on the 125 C row and 37.2 W on the 175 C row. The current that a given loss supports therefore falls with temperature as the square root of the resistance ratio, which is about 1.5 between 25 C and 125 C. A board quoted at 30 A on the strength of the 25 C row is quoting a number that exists only on a cold bench.
The thermal pair is consistent on this sheet: at a 25 C case the allowed rise to a 175 C junction is 150 C, and 150 divided by 1.1 gives 136 W, which is the printed dissipation. At a 125 C case the rise is 50 C and 50 divided by 1.1 gives 45 W, again the printed figure. That internal consistency is worth noting because three other sheets in this shipment fail it.
In still air the part sees 50 C per watt, which supports 3.0 W at a 25 C ambient and 2.5 W at 50 C, equal to 9.53 A and 8.70 A on the 25 C on resistance. That is a better still air figure than the P channel sibling by a factor of 2.7, and it comes from the larger die and the 1.1 C per watt case path rather than from a different package.
An early source of trouble: the parametric note
Note d on page one reads that parametric verification is ongoing. That is a supplier statement that some of the rows have not been fully characterised, and it does not say which ones. For a buyer it matters more than any single number on the sheet, because a qualification cannot lean on a row that the supplier has not finished measuring. The two rows to treat with the most caution are the ones with an unusual shape rather than a familiar one: the on resistance at 175 C, which is only 2.8 times the 25 C value on a trench die, and the 45 W dissipation at a 125 C case, which follows the thermal pair exactly and is therefore fine.
The practical response is to measure rather than to trust. On a first article, measure on resistance at 25 C, at 100 C and at the hot case temperature, and compare the slope with the printed rows. A part that measures 2.8 times at 175 C is behaving as the sheet says; one that measures 4 times has a different die and belongs in the failure file, not on the line.
Where the 175 C junction is worth paying for
A 175 C part is not for a hotter ambient alone. It is for a board that is thermally tight and cannot afford a heatsink, where 25 C of extra junction room buys 25 C of case margin at the same dissipation. In a sealed enclosure at 60 C ambient with a 1.1 C per watt case path, that is the difference between a 20 A load and a 26 A load at the same heatsink.
The other use is a load switch that sees a short circuit. A 96 mJ avalanche rating and a 44 A avalanche current are modest but real, and a 175 C junction gives the die time to reach the protection before the junction fails. That is the difference between a fuse replacement and a board replacement in the field.
For a board where the P channel switch stays on all the time, the 33 milliohm at 10 A is 3.3 W, which the 50 C per watt ambient path will not remove without copper. Our supplier audit records the hot resistance measurement on the qualification sample, and the shortage recovery work uses that record to compare an alternate die rather than an alternate label.
The 4433 pF input capacitance and 96 nC of gate charge are the price of a die that holds 33 milliohm at minus 100 V. At 50 kHz and a 10 V drive the gate costs 0.048 W, which is nothing, but the same capacitance makes the turn off delay 78 ns against a 15 ns fall, so the part spends most of its transition in the plateau where current and voltage are both present. That is where the loss is generated, and it is why a 100 V P channel part belongs at 50 kHz rather than at 300 kHz.
Questions before a reel is booked
First, the unfinished parametric work. Ask which rows are still open, and do not sign a qualification that depends on one of them without a measurement.
Second, the gate charge. 144 nC maximum is the highest in the P channel band here, so a weak driver costs switching time. The 10 V row and the 4.5 V row differ by only 0.004 ohm, so a logic level drive is cheap in conduction and expensive in nothing.
Third, the package limit. The source current row is explicitly package limited at minus 50 A, so the die and the lead frame are the two constraints and the wire bonds decide which arrives first. A pulse test that runs at 2 per cent duty will not show it.