HX5141K00VP
Product Specifications
HX5141K00VP
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HX5141K00VP from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HX5141K00VP: nine hundred watts per side from DC to 1 GHz on a 50 volt rail
The HX5141K00VP is a gallium nitride power transistor from Hisiwell with a DC to 1 GHz band, a 50 V rail, 900 W per side of saturation, 16 dB of power gain and 57 per cent drain efficiency, in pulse mode. The index row writes the output as 900 times two, which is the vendor notation for a part used as a pair: two devices in one package or two matched halves driven in a balanced configuration.
Read as a single device, 900 W is 59.54 dBm. Read as a pair, 1800 W is 62.55 dBm, which is 3.01 dB above the single side. The distinction matters for the purchase order, because a quotation for one side and a quotation for a balanced pair differ by a factor of two in power and in price.
Sixteen decibels of gain at 900 W per side means 22.6 W of drive per side, or 43.54 dBm. That is a driver amplifier, not a driver stage: 22.6 W is a part with its own flange and its own bias. In a balanced pair the drive is split by a 3 dB hybrid, so the driver has to deliver 45.1 dBm into the hybrid to place 22.6 W at each side.
The efficiency of 57 per cent at 900 W means the drain takes 1,579 W per side, which at 50 V is 31.6 A per side. Two sides are 3,158 W of DC input and 63.2 A, with 1,358 W of heat to remove during the pulse. That is a liquid cooled plate, and the pulse duty cycle is what turns 1,358 W of instantaneous heat into an average the plate can carry.
The band is DC to 1 GHz, so the part is an L band and lower device: IFF, air traffic radar, electronic countermeasures and industrial RF all sit inside that window. The band is not a narrow window, it is everything below 1 GHz, and an unmatched part used across the whole of it needs a network that is tuned per application rather than per part.
The parameter rows behind the HX5141K00VP
| Part class | Gallium nitride HEMT power transistor, unmatched, supplied as a pair |
| Frequency range | DC to 1 GHz |
| Band width, calculated | 1,000 MHz |
| Saturation output per side, index row | 900 W |
| Per side in dBm, calculated | 59.54 dBm |
| Pair output, calculated | 1,800 W |
| Pair in dBm, calculated | 62.55 dBm |
| Power gain | 16 dB |
| Gain as a ratio, calculated | 39.8 times |
| Drive per side, calculated | 22.6 W, 43.54 dBm |
| Drive into the hybrid for a pair, calculated | 45.1 dBm, 32 W |
| Drain efficiency | 57 per cent |
| DC input per side at 57 per cent, calculated | 1,579 W |
| Drain current per side, calculated | 31.6 A at 50 V |
| DC input for the pair, calculated | 3,158 W, 63.2 A |
| Heat per side, calculated | 679 W during the pulse |
| Heat for the pair, calculated | 1,358 W during the pulse |
| Drain rail | 50 V |
| Mode | Pulse |
| Pulse width and duty cycle | Not published, and they set the average heat |
| Load voltage per side at 50 ohm, calculated | 212.1 V RMS, 300.0 V peak |
| Load voltage per side at 12.5 ohm, calculated | 106.1 V RMS, 150.0 V peak |
| Output per gigahertz of band, calculated | 900 W per GHz per side |
| Matching | Unmatched, network on the customer board |
| Package and body | Not published on the index row |
| Thermal resistance, junction to case | Not published |
| Pulse droop and thermal derating curves | Not published |
Thirty two amps per side at fifty volts
Thirty one point six amps at 50 V is not a trace, it is a busbar or a thick copper inlay, and the decoupling bank is measured in hundreds of microfarads rather than in tens. At a 10 per cent duty cycle the average current is 3.16 A and the average heat is 68 W per side, which a liquid plate carries. At a 30 per cent duty cycle the average heat is 204 W per side and the plate has to be sized for it.
The pulse width matters for a second reason. The die heats during the pulse and the transient thermal impedance decides how far the junction moves in 100 microseconds. No curve is published for it, so the safe starting assumption is the DC thermal resistance plus a margin, and the first article is measured with a pulse train at the intended width.
The load voltage is where the impedance choice shows. At 50 ohm a single side delivers 300 V peak, which needs a 500 V capacitor and a match network built for it. At 12.5 ohm the peak is 150 V and 100 V parts are marginal, 250 V parts comfortable. High power L band systems run 12.5 or 25 ohm at the device for exactly this reason, and the balun that gets from there to 50 ohm is part of the amplifier.
The gain is high for a 900 W part. Sixteen decibels means 22.6 W of drive, which is 2.5 per cent of the output, and that is a comfortable ratio for a pulsed radar where the driver can be a single packaged part with its own protection.
HX5141K00VP against the other high power rows
| HX5141K00VP | DC to 1 GHz | 900 W per side, 1,800 W as a pair | 16 dB | 57 per cent | Reference point |
| HX510900RVPS | DC to 1 GHz | 450 W per side | Not published | Not published | Half the output per side, continuous wave row |
| HX13470P | DC to 1.4 GHz | 470 W | 18 dB | 82 per cent | Half the output on a 48 V rail, much higher efficiency |
| HX13240F | DC to 1.4 GHz | 240 W | 18 dB | 82 per cent | Quarter of the output, continuous wave |
| HX530300VP | DC to 3 GHz | 150 W per side | Not published | Not published | Much wider band, much lower output |
| HX25600F | DC to 2.5 GHz | 600 W | 17 dB | 69 per cent | Same order of power on a 48 V rail |
The comparison that matters is with the 48 V family. The HX13470P delivers 470 W at 82 per cent efficiency on 48 V, which is 103 W of heat for 470 W of output. This part delivers 900 W per side at 57 per cent on 50 V, which is 679 W of heat. Efficiency falls as the output rises inside the same band, and the pulse mode is what makes the lower efficiency tolerable.
Against the 450 W continuous member of the same band the mode difference is the whole story. A continuous wave 450 W part has to hold its heat forever, a pulsed 900 W part averages it. Choosing between them is a question about the transmit duty cycle of the system, not about the transistor.
The high power rows at L band are collected on RF power transistor cross reference, and the way a pulsed part is qualified with its driver and its plate is on RF procurement.
Board notes for a nine hundred watt pulse stage
The first item is the definition of two. The index row reads 900 times two, and a purchase order should state whether it is one side, a pair, or two matched devices, before a price is compared with a competitor.
The second item is the impedance. At 12.5 ohm the peak voltage is 150 V per side and the current is 8.5 A per side at 900 W, which is a practical match with 250 V parts and a balun to 50 ohm.
The third item is the pulse. With no pulse width, duty cycle or transient thermal curve published, the first article is measured with the intended pulse train, and the plate is sized on the average heat at that duty cycle.
The fourth item is the bias. A 50 V rail with a 31.6 A pulse current needs a supply that holds the rail during the pulse, which means the bulk bank sits close to the device and the supply lead is short and heavy.
Questions buyers ask about HX5141K00VP
Is 900 W the output of the whole part? The row reads 900 times two, so 900 W is the per side figure and 1800 W is the pair. The order has to state which one is being quoted.
Is it continuous wave? The mode row reads pulse. A continuous use at this power needs a written confirmation and a much larger plate.
What is the drive? 22.6 W per side at 16 dB of gain, and 32 W into the hybrid for a balanced pair.
What is the peak voltage at the output? 300 V at 50 ohm and 150 V at 12.5 ohm, both calculated from the 900 W per side figure.
How do we start? Send the band, the pulse width, the duty cycle, the output at the antenna, the impedance and the rail. We will confirm the pulse ratings with the factory, quote from the schedule and ship a sample measured at the band edges under the intended pulse.