Product Specifications

HX446030F2 — Discrete & Power Semiconductors | Superb Automation

HX446030F2

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HX446030F2 from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HX446030F2: thirty watts at 4.4 to 6 GHz with fifty five per cent drain efficiency

The HX446030F2 is an unmatched gallium nitride power transistor from Hisiwell on a 28 V rail covering 4.4 to 6 GHz. The index row reads 30 W of saturation, 14 dB of power gain, 55 per cent drain efficiency and continuous wave operation. There is no peak column and no average column, which makes this one of the few parts on the shelf that can be budgeted without an operating point argument.

Thirty watts is 44.77 dBm by calculation. With 14 dB of gain the drive at saturation is 1.19 W, which is 30.77 dBm, so the driver is a two stage line up rather than a single small signal amplifier. The gain is 1 dB below the 50 W member of the same band, which is the usual trade when a vendor keeps the same die family and takes less output from it.

The efficiency is the reason to look at this part. At 55 per cent the drain takes 54.5 W and the part leaves 24.5 W of heat for 30 W of output. A 26 per cent part at the same output would leave 85.4 W. That difference decides whether the amplifier fits a small extrusion with a fan or needs a liquid cooled plate, and it is measured at saturation, not at a backed off point.

The band is 1.6 GHz wide, which at a 5.2 GHz centre is 30.8 per cent fractional. For an unmatched 28 V device that is a wide window, and it is why the match has to be built on the customer board rather than bought inside the package. The gain flatness across the window is not published, so the 14 dB is a single figure and the flatness is a measurement on the first article.

The rail is 28 V in the index row. At 1.95 A of drain current, the DC feed is a normal 28 V supply with a choke rated above 3 A and a bulk bank sized for the envelope at the crest of a modulated signal.

The parameter rows behind the HX446030F2

Part classGallium nitride HEMT power transistor, unmatched
Frequency range4.4 to 6 GHz
Band width, calculated1,600 MHz
Fractional bandwidth at 5.2 GHz centre, calculated30.8 per cent
Saturation output, index row30 W
Saturation in dBm, calculated44.77 dBm
Peak output columnNot published, saturation only
Average output columnNot published
Power gain14 dB
Gain as a ratio, calculated25.1 times
Drive at saturation, calculated1.19 W, 30.77 dBm
Drain efficiency55 per cent
DC input at 55 per cent, calculated54.5 W
Drain current, calculated1.95 A at 28 V
Heat at saturation, calculated24.5 W
Heat at 26 per cent for the same output, calculated85.4 W, the comparison that matters
Drain rail28 V
ModeContinuous wave
Load voltage at 50 ohm, calculated38.7 V RMS, 54.8 V peak
Load voltage under a two to one mismatch, calculated77.5 V peak
Output per gigahertz of band, calculated18.8 W per GHz
MatchingUnmatched, network on the customer board
Package and bodyNot published on the index row
Thermal resistance, junction to caseNot published
Gain flatness over the bandNot published
Gate bias point and quiescent currentNot published

Fifty four watts in and thirty watts out

The DC budget is 54.5 W at 1.95 A. That is a 28 V supply of 60 W minimum with 20 per cent headroom for the sag at the crest of a modulated carrier. The choke and the feed trace are the parts that get overlooked: 1.95 A average with a crest factor of six means a peak of nearly 8 A in the drain lead for a short interval, and a choke rated at 2 A saturates there.

Twenty four and a half watts of heat on a 30 W device is a comfortable ratio. A flange or a copper coin with a via field handles it on a forced air sink. What matters is the interface: a bolted flange with a dry joint reads 15 to 20 degrees higher at the junction than the same flange with a thin thermal interface, and at 24.5 W that is the difference between a 120 degree and a 145 degree junction.

At the output, 38.7 V RMS and 54.8 V peak at 50 ohm leave 100 V capacitors with margin. Under a two to one mismatch the peak reaches 77.5 V, which is still inside the rating, but the current in the matching network rises with the mismatch and the inductors have to be rated for the higher circulating current rather than for the matched case.

The band is 30.8 per cent, and on a low loss laminate a two section ladder holds that. The dielectric constant of the laminate sets the electrical length of every section, so the stack is selected before the first tuning pass and not after.

HX446030F2 against the other members of the shelf

HX446030F24.4 to 6 GHz30 W saturation14 dB55 per centReference point
HX446050F24.4 to 6 GHz50 W saturation15 dB55 per cent2.22 dB more output, 1 dB more gain, same efficiency
HX5060140P25 to 6 GHz140 W saturation11 dB50 per cent6.69 dB more output, 3 dB less gain, needs 11 W of drive
HXN502094.4 to 5.9 GHz15 W saturation, 25 W peak, 2 W average15 dB26 per cent3.01 dB less output, 1 dB more gain, twice the heat per watt
HXN502145 to 6 GHz50 W peakNot publishedNot publishedSame output class on a narrower window, no efficiency row
HXN502225 to 6 GHz140 W peakNot publishedNot published1.46 dB more peak, pulse mode, narrower window

Inside the same band the choice between this part and the HX446050F2 is a power decision and nothing else: 2.22 dB of output, 1 dB of gain, the same efficiency. The drive power barely moves, 1.19 W against 1.58 W, so the driver line up is the same in both cases. The heat does move, 24.5 W against 40.9 W, and that is the line item that changes the enclosure.

Against the 140 W HX5060140P2 the trade is drive power. Eleven decibels of gain at 140 W means 11.1 W of drive, which is a part in its own right and a second thermal problem. Where the system can carry 30 W at the antenna, this part keeps the whole amplifier inside one small box.

The 4.4 to 6 GHz window is on the how to choose an RF amplifier page, which walks through the gain and efficiency trade at the system level, and one stop RF supply covers how the driver, the transistor and the passives are quoted as one kit.

Board notes for a thirty watt continuous stage

The first item is the match. A 30.8 per cent window means two sections and a low loss laminate, and it means the network is tuned at three frequencies rather than one, because a match at the band centre can hide a 3 dB roll at 6 GHz.

The second item is the bias. Fourteen decibels of gain at 5 GHz with no published quiescent current means the operating class is chosen at the first article. For continuous wave the point is set for gain and for a modulated carrier it is set lower for linearity, and the two settings want different gate networks.

The third item is the thermal interface. At 24.5 W the flange joint is the only thermal decision that matters, and it is the one that is easiest to get wrong under time pressure at the assembly line.

The fourth item is identification. The index row does not state a package, so a purchase order should carry the part number, the band, the power and the efficiency, and the sample should be measured at 4.4, 5.2 and 6 GHz before the reel is released.

Questions buyers ask about HX446030F2

Is 55 per cent measured at saturation? The index row gives one efficiency figure and one power figure, both at saturation, so the 55 per cent belongs to that point. At a backed off point it is lower.

What is the drive power? 1.19 W at 14 dB of gain and 30 W of output, which is 30.77 dBm. A two stage driver covers it.

Is it continuous wave only? The mode column reads continuous wave. A pulsed application needs a written confirmation of the pulse width and the duty cycle, because neither is published.

Does it cover 6 GHz fully? The row states 4.4 to 6 GHz. Gain flatness at the top of the window is not published, so the 6 GHz point is confirmed on a sample.

How do we start? Send the band, the output at the connector, the signal, the ambient and the rail. We will quote from the schedule and ship a sample with gain and efficiency measured at 4.4, 5.2 and 6 GHz.