Contact Us

HX2580258GX

Brand: Hisiwell
Hisiwell HX2580258GX is a discrete semiconductors component designed for DC-DC Converters & Power Supplies and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

HX2580258GX — Discrete & Power Semiconductors | Superb Automation

HX2580258GX

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HX2580258GX from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HX2580258GX: twenty five watts peak and four watts average in the 5.2 to 5.9 GHz window

The HX2580258GX is an unmatched gallium nitride HEMT from Hisiwell for the sub 6 GHz region, quoted at 25 W and marked for LTE, LTE-A and LTE-U as well as continuous wave and pulsed operation. The family index fills three columns that the rest of the 5 GHz group leaves blank: 25 W in the peak column, 4 W in the average column, 12 dB of gain and 25 per cent efficiency. The mode column reads 5.2 to 5.9 GHz rather than a mode word.

That averages to a peak to average ratio of 7.96 dB, which is what a 4 W average against a 25 W peak implies. It is close to the 8 dB crest factor of an LTE carrier with a high order modulation, so the pair of figures is coherent rather than accidental. It also means the 25 per cent efficiency is most likely measured at the average point rather than at saturation, because 25 per cent at saturation would be unusually low for a GaN device at 5 GHz and 25 per cent at a backed off average is normal.

Twenty five watts peak is 43.98 dBm and 4 W average is 36.02 dBm. With 12 dB of gain the drive at peak is 31.98 dBm, which is 1.58 W, and at the average point it is 24.02 dBm, 0.25 W. At 25 per cent efficiency the peak DC input is 100 W, the current is 3.57 A at 28 V and the heat is 75 W during the peak; at the average point the DC input is 16 W, 0.57 A and 12 W of heat.

The mode column is the odd one. A frequency range in the mode column means the vendor has not stated whether the part is characterised continuous wave or pulsed, or has stated it in a field that was overwritten. The prose says both, so the page treats the mode as unconfirmed and asks for it in writing.

The parameter rows behind the HX2580258GX

Part classUnmatched gallium nitride HEMT power transistor
Frequency range, mode column5.2 to 5.9 GHz, a frequency range in place of a mode
Frequency range, product proseSub 6 GHz
Peak output, index row25 W
Average output, index row4 W
Peak in dBm, calculated43.98 dBm
Average in dBm, calculated36.02 dBm
Peak to average ratio implied, calculated7.96 dB
Power gain12 dB
Drive at peak, calculated31.98 dBm, 1.58 W
Drive at average, calculated24.02 dBm, 0.25 W
Drain efficiency25 per cent
DC input at peak and 25 per cent, calculated100 W, 3.57 A, 75 W of heat
DC input at average and 25 per cent, calculated16 W, 0.57 A, 12 W of heat
Drain rail28 V
Operating modeNot stated in the mode column, prose lists continuous wave and pulsed
Load voltage at 50 ohm, calculated35.4 V RMS, 50.0 V peak at 25 W
Load voltage at the average point, calculated14.1 V RMS, 20.0 V peak at 4 W
Band width, calculated700 MHz on the index window
Output per GHz of band, calculated16.7 W per GHz on the index window
MatchingUnmatched, external network on the customer board
Body and packageNot published
Thermal resistance, junction to caseNot published
Input and output impedanceNot published in text
Gate bias point and quiescent currentNot published
Duty cycle and pulse width limitsNot published
Orderable addendum, marking and packingNot published

Three and a half amps at peak and half an amp on average

The two operating points have to be handled separately. At peak the drain draws 3.57 A and the part leaves 75 W of heat for a few hundred microseconds or for the crest of a modulated envelope. At the average point the drain draws 0.57 A and the part leaves 12 W. The sink is sized on the average, and the device is sized on the peak.

That split is what makes a 4 W average part look small in the DC budget and large in the thermal one. A 12 W average dissipation fits a modest extrusion. A 75 W peak dissipation for the duration of the pulse does not change the sink, because the thermal time constant of the sink is far longer than the pulse, but it does set the transient thermal impedance requirement, and no curve is published for it.

Three point six amps at 28 V is a 175 mil trace at one ounce copper and a choke with a 5 A saturation rating. The bulk bank is sized for the envelope current at the crest, which is what the 3.57 A peak figure describes, not for the 0.57 A average.

At the output, 50.0 V peak at 25 W and about 71 V peak under a two to one mismatch. That is a comfortable range for 100 V parts, which makes the match on this part cheaper than on the 200 W members. The band is 700 MHz wide, and at 5.5 GHz that is 13 per cent, so a two section match holds it.

HX2580258GX against the 5 GHz region

HX2580258GX5.2 to 5.9 GHz25 W peak, 4 W average12 dB25 per centReference point
HXN502094.4 to 5.9 GHz15 W saturation, 25 W peak, 2 W average15 dB26 per cent2.22 dB below on saturation, wider band
HX446030F24.4 to 6 GHz30 W14 dB55 per cent0.79 dB above, more than twice the efficiency
HX446050F24.4 to 6 GHz50 W15 dB55 per cent3.01 dB above
HX5060140P25 to 6 GHz140 W11 dB50 per cent7.48 dB above, much lower gain
HXN502225 to 6 GHz140 W peakNot publishedNot published7.48 dB above, pulse row

The efficiency row is where this part has to be read carefully. Twenty five per cent against 55 per cent on the HX446030F2 next to it is a factor of two in heat for the same output, and at 25 W that is the difference between 75 W and 34 W of peak dissipation. If the 25 per cent is an average point figure and the 55 per cent is a saturation figure, the two are not comparable, and the page says so rather than ranking them.

The gain row is where it wins. Twelve decibels at 5.5 GHz is more than the 11 dB of the 140 W HX5060140P2 and close to the 14 dB of the 4.4 to 6 GHz pair, and at 25 W the drive is 1.58 W rather than the tens of watts a 140 W part needs.

The whole 5 GHz region is on the RF power transistor cross reference, which is the page to use when the efficiency figures have to be compared with a note of the operating point, and RF component sourcing covers how a measured set of curves is requested with the order.

Board notes for a sub six gigahertz stage at twenty five watts

The first item is the operating point question. A part quoted at 25 W peak and 4 W average is a part meant for a modulated carrier, and the 25 per cent efficiency most likely belongs to the average point. Before the sink is sized, the factory has to say which point each figure belongs to, because a sink sized on 12 W and a part dissipating 75 W at saturation is a part that shuts down on the first continuous wave test.

The second item is the match. 5.2 to 5.9 GHz is 13 per cent, and at 25 W the match is a two section ladder on a low loss laminate with 100 V capacitors. The board material still matters at 5.5 GHz, so the stack is fixed before the network is tuned.

The third item is the bias. No gate voltage and no quiescent current is published, and for a modulated application the bias point sets the linearity. A class AB point with a temperature compensated network is the normal starting point, and the actual point is set on the first article against the linearity the system needs.

The fourth item is the identification. The part number of this page sits at a vendor address that has also served a different part number in the same family, so a purchase order should carry the part number, the band and the power, and a sample should be measured before a reel is released to the line.

Questions buyers ask about HX2580258GX

Is 25 W peak or average? It is the peak column. The average column reads 4 W, so the part is meant for a modulated carrier with about 8 dB of crest factor.

Is the 25 per cent efficiency at peak or at average? Not stated. The value is low for a GaN device at saturation and normal for a backed off average point, so it is quoted as unconfirmed and settled with the factory before a sink is sized.

What is the band? 5.2 to 5.9 GHz in the index and sub 6 GHz in the prose. The narrower window is the one with a published row, so it is the one we quote.

Is it continuous wave capable? The prose lists continuous wave and pulsed. The mode column carries a frequency range instead of a mode, so a continuous wave application needs a written confirmation and a thermal measurement.

How do we start? Send the band, the signal and its crest factor, the average output, the ambient and the rail. We will confirm the operating point with the factory, quote from the schedule and ship a sample measured at the band centre under the intended signal.