Product Specifications

HX13470P — Discrete & Power Semiconductors | Superb Automation

HX13470P

Hisiwell — Discrete & Power Semiconductors

Product Overview

The HX13470P from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • Low Rds(on) for minimal conduction losses in power switching
  • Fast switching speed with low gate charge for high-frequency operation
  • Avalanche-rated for robust operation under inductive load conditions
  • High junction temperature rating for demanding environments
  • Logic-level gate drive compatible for simplified design
  • RoHS and AEC-Q101 qualified options available

Key Specifications

Vds / VceV
Id / IcA
Rds(on) / Vce(sat)mΩ
QgnC
Technology—
Package—
Configuration—
Mounting—

Applications

Switch-Mode Power Supplies Motor Drives & Inverters Battery Management Systems DC-DC Converters Load Switching Automotive Power Distribution

Request Quote — In Stock, 100% New & Original, Full Warranty

HX13470P: four hundred and seventy watts from DC to 1.4 GHz at eighty two per cent

The HX13470P is a gallium nitride power transistor from Hisiwell on a 48 V rail with a DC to 1.4 GHz band, 470 W of saturation, 18 dB of power gain and 82 per cent drain efficiency in continuous wave. Four hundred and seventy watts is 56.72 dBm. The efficiency is the figure that makes this part interesting: at 82 per cent it leaves 103 W of heat for 470 W of output, a ratio that no 28 V part on the 5 GHz shelf comes close to.

Eighteen decibels of gain at 470 W means 7.45 W of drive, or 38.72 dBm. That is a small packaged amplifier rather than a power stage, which keeps the line up to two devices and the board to one sink.

Eighty two per cent at 470 W is a high number and it deserves a note. Vendor efficiency figures at this level are usually measured at saturation with a tuned load at one frequency, often the band centre, and the figure across the band is lower. The DC budget on this page uses the published 82 per cent as given and the page says plainly that the band edge efficiency is a measurement, not a datasheet row.

The band runs from DC to 1.4 GHz, which covers FM broadcast, DME and TACAN, L band radar, industrial RF heating and plasma drive. The part is unmatched, so the network is per application: an FM transmitter at 100 MHz and a 1.3 GHz radar do not share a match even though they share a transistor.

The rail is 48 V, which is the telecom and industrial standard and the reason this part fits a rack rather than a special supply. At 11.94 A of drain current a 48 V feed is a normal busbar and a normal choke, not a special build.

The parameter rows behind the HX13470P

Part classGallium nitride HEMT power transistor, unmatched
Frequency rangeDC to 1.4 GHz
Band width, calculated1,400 MHz
Saturation output, index row470 W
Saturation in dBm, calculated56.72 dBm
Power gain18 dB
Gain as a ratio, calculated63.1 times
Drive at saturation, calculated7.45 W, 38.72 dBm
Drain efficiency82 per cent
DC input at 82 per cent, calculated573.2 W
Drain current, calculated11.94 A at 48 V
Heat at saturation, calculated103.2 W
Heat per watt of output, calculated0.22 W of heat for every watt delivered
Efficiency at the band edgesNot published, measured on the first article
Drain rail48 V
ModeContinuous wave
Load voltage at 50 ohm, calculated153.3 V RMS, 216.8 V peak
Load voltage under a two to one mismatch, calculated306.6 V peak
Load voltage at 12.5 ohm, calculated76.6 V RMS, 108.4 V peak
Output per gigahertz of band, calculated335.7 W per GHz
MatchingUnmatched, network on the customer board
Package and bodyNot published on the index row
Thermal resistance, junction to caseNot published
Compression pointNot published
Gain flatness over the bandNot published

Eleven point nine amps and a hundred and three watts of heat

The supply is a 48 V rail at 12 A, which is a standard industrial supply with headroom. The choke is rated above 18 A for the crest of a modulated signal and the bulk bank is sized for the envelope rather than the average.

One hundred and three watts of heat for 470 W of output is the number that makes a continuous 470 W amplifier feasible on a forced air sink with a copper spreader, rather than on a liquid plate. That is a real cost difference at this power, and it is entirely the efficiency figure doing the work.

The output voltage is the constraint that replaces the thermal one. Two hundred and seventeen volts peak at 50 ohm is beyond ordinary ceramics, so the network at 50 ohm is built with 500 V parts. At 12.5 ohm the peak falls to 108 V and 250 V parts are comfortable, which is what most high power L band amplifiers do.

Three hundred and thirty six watts per gigahertz of band is a measure of how much of the spectrum this part covers with one device. A 470 W part that holds from DC to 1.4 GHz replaces three narrow band parts in a multi band rack.

HX13470P against the other 48 volt rows

HX13470PDC to 1.4 GHz470 W saturation18 dB82 per centReference point
HX13240FDC to 1.4 GHz240 W saturation18 dB82 per cent2.92 dB less output, same gain and efficiency
HX25600FDC to 2.5 GHz600 W saturation17 dB69 per cent1.06 dB more output, wider band, lower efficiency
HX25400FDC to 2.5 GHz400 W saturation19 dB71 per cent0.70 dB less output, 1 dB more gain
HX04200FDC to 4 GHz200 W saturation20 dB70 per cent3.71 dB less output on a much wider band
HX5141K00VPDC to 1 GHz900 W per side16 dB57 per cent2.82 dB more per side, pulse only, 50 V rail

The pair with the HX13240F is the cleanest comparison on the page: same band, same gain, same efficiency, 2.92 dB apart. That means the choice is purely an output decision, and the drive power scales with it, 7.45 W against 3.80 W.

Against the 2.5 GHz family the band is the trade. Six hundred watts over 2.5 GHz at 69 per cent, or 470 W over 1.4 GHz at 82 per cent. A system that needs the band takes the wider part and pays in heat; a system that needs the efficiency takes this one and stays below 1.4 GHz.

The 48 V rows are indexed on RF power transistor cross reference, and the way a 470 W stage is quoted with its driver and its passives is on one stop RF supply.

Board notes for a four hundred and seventy watt stage

The first item is the efficiency at the band edges. Eighty two per cent at saturation is the published figure and it belongs to a tuned point. At 1.4 GHz it will be lower, and the heat budget is checked at the top of the band on the first article.

The second item is the output impedance. At 50 ohm the peak is 217 V, which forces 500 V parts. Running the device at 12.5 ohm brings the peak to 108 V and makes 250 V ceramics usable.

The third item is the current path. At 12 A continuous the feed is a busbar or a 3 ounce trace, and the choke is rated above 18 A so the crest does not saturate it.

The fourth item is the bias. Eighteen decibels of gain with no published quiescent current means the class is set on the first article, and the gate network is temperature compensated so the point holds over a long continuous run.

Questions buyers ask about HX13470P

Is 82 per cent measured at saturation? Yes, and at a tuned point. The band edge figure is lower and it is measured on the first article rather than quoted.

What is the drive power? 7.45 W at 18 dB of gain, which is 38.72 dBm.

Is 470 W continuous? The mode row reads continuous wave, so yes, with a sink sized on the 103 W of heat.

Does it cover the whole band from DC? The row says DC to 1.4 GHz. The match is per application, so a 100 MHz transmitter and a 1.3 GHz radar use different networks on the same device.

How do we start? Send the band, the output at the connector, the signal, the ambient and the rail. We will quote from the schedule and ship a sample with gain and efficiency measured at 100 MHz, the band centre and 1.4 GHz.