Product Specifications
HX13240F
Hisiwell — Discrete & Power Semiconductors
Product Overview
The HX13240F from Hisiwell is a discrete power semiconductor delivering efficient switching and power conversion. Hisiwell is a recognized semiconductor supplier providing reliable components for global electronics manufacturing.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- Low Rds(on) for minimal conduction losses in power switching
- Fast switching speed with low gate charge for high-frequency operation
- Avalanche-rated for robust operation under inductive load conditions
- High junction temperature rating for demanding environments
- Logic-level gate drive compatible for simplified design
- RoHS and AEC-Q101 qualified options available
Key Specifications
| Vds / Vce | V |
| Id / Ic | A |
| Rds(on) / Vce(sat) | mΩ |
| Qg | nC |
| Technology | — |
| Package | — |
| Configuration | — |
| Mounting | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
HX13240F: two hundred and forty watts from DC to 1.4 GHz at eighty two per cent
The HX13240F is the smaller member of the 48 V pair from Hisiwell, on the same DC to 1.4 GHz band with 240 W of saturation, 18 dB of power gain and 82 per cent drain efficiency in continuous wave. Two hundred and forty watts is 53.80 dBm. The rows are identical to the 470 W part except for the output, which makes the pair easy to work with: one network family, one bias scheme, two power levels.
Eighteen decibels of gain at 240 W means 3.80 W of drive, or 35.80 dBm. That is a single packaged driver on the same board, which keeps the whole amplifier to two devices and one sink.
Eighty two per cent at 240 W means the drain takes 292.7 W and the part leaves 52.7 W of heat. Fifty three watts is a forced air sink with a copper spreader, no liquid plate, which is what makes a 240 W continuous amplifier practical in a rack.
The band runs from DC to 1.4 GHz and covers FM broadcast, DME and TACAN, L band radar, industrial heating and plasma drive. The part is unmatched, so the same device serves a 100 MHz transmitter and a 1.3 GHz radar with different networks.
The rail is 48 V, the drain current 6.10 A. That is a normal busbar, a normal choke and a supply that is bought rather than built.
The parameter rows behind the HX13240F
| Part class | Gallium nitride HEMT power transistor, unmatched |
| Frequency range | DC to 1.4 GHz |
| Band width, calculated | 1,400 MHz |
| Saturation output, index row | 240 W |
| Saturation in dBm, calculated | 53.80 dBm |
| Power gain | 18 dB |
| Gain as a ratio, calculated | 63.1 times |
| Drive at saturation, calculated | 3.80 W, 35.80 dBm |
| Drain efficiency | 82 per cent |
| DC input at 82 per cent, calculated | 292.7 W |
| Drain current, calculated | 6.10 A at 48 V |
| Heat at saturation, calculated | 52.7 W |
| Heat per watt of output, calculated | 0.22 W of heat for every watt delivered |
| Output against the 470 W member, calculated | 2.92 dB lower |
| Efficiency at the band edges | Not published, measured on the first article |
| Drain rail | 48 V |
| Mode | Continuous wave |
| Load voltage at 50 ohm, calculated | 109.5 V RMS, 154.9 V peak |
| Load voltage under a two to one mismatch, calculated | 219.1 V peak |
| Load voltage at 12.5 ohm, calculated | 54.8 V RMS, 77.5 V peak |
| Output per gigahertz of band, calculated | 171.4 W per GHz |
| Matching | Unmatched, network on the customer board |
| Package and body | Not published on the index row |
| Thermal resistance, junction to case | Not published |
| Compression point | Not published |
Six amps and fifty three watts of heat
Six point one amps at 48 V is a 300 mil trace at 2 ounce copper or a small busbar, a choke rated above 9 A for the crest and a bulk bank that holds the rail through the envelope. That is a normal industrial build, not a special one.
Fifty two point seven watts of heat is the figure that makes this part popular for a rack amplifier. A copper spreader and a forced air sink carry it at an ambient of 40 degrees, and the junction stays inside a lifetime that a telecom or broadcast product can quote.
The output voltage at 50 ohm is 155 V peak and 219 V under mismatch, which needs 500 V parts in the network. At 12.5 ohm the peak falls to 77.5 V and 250 V parts are comfortable, and most high power broadcast and radar amplifiers run the device below 25 ohm for this reason.
One hundred and seventy one watts per gigahertz of band is the measure of spectrum coverage. A 240 W part that holds from DC to 1.4 GHz is a single platform for a whole product line, and that is often worth more than the extra 2.92 dB the larger member delivers.
There is a second reader for the same row. A part quoted at DC is quoted with a lower frequency limit that is a rail limit rather than a match limit: below 100 MHz the match becomes large and lossy, and the practical floor for a 240 W stage is usually the band of the application rather than the DC in the table. A 100 MHz broadcast transmitter is well inside that practical floor. A 3 MHz industrial driver is not, and it needs a network that is built for that decade.
The supply side is the last item worth pricing before the part is chosen. Six point one amps on 48 V is inside the range of a standard single output industrial module, and that module is usually already in the rack for other reasons. A 28 V part at the same output would draw 10.5 A and need its own supply, which is a real cost at the system level even when the transistor costs less.
HX13240F against the other 48 volt rows
| HX13240F | DC to 1.4 GHz | 240 W saturation | 18 dB | 82 per cent | Reference point |
| HX13470P | DC to 1.4 GHz | 470 W saturation | 18 dB | 82 per cent | 2.92 dB more output, 50.5 W more heat |
| HX25400F | DC to 2.5 GHz | 400 W saturation | 19 dB | 71 per cent | 2.22 dB more output on a wider band, 1 dB more gain |
| HX04200F | DC to 4 GHz | 200 W saturation | 20 dB | 70 per cent | 0.79 dB less output, 2 dB more gain, three times the band |
| HX520240V | DC to 2 GHz | 240 W saturation | Not published | Not published | Same output on a 50 V rail with no gain or efficiency |
| HX560050V | DC to 4 GHz | 50 W saturation | Not published | Not published | Much wider band, much lower output |
The comparison with the 400 W part on 2.5 GHz is the one that decides platform strategy. Two point two decibels more output and 800 MHz more band at 71 per cent efficiency, which is 42 W of extra heat at the same output class. For a product that needs the band, the wider part wins; for a product that runs at one frequency, the 82 per cent part wins on heat and on supply size.
Against the 50 V 240 W part the difference is the rail and the paperwork. Same output, no gain row and no efficiency row on the 50 V part, so the 48 V part is the one that can be planned from a datasheet.
The 48 V rows are collected on RF power transistor cross reference, and the way a 240 W stage is kitted with its driver and its passives is on one stop RF supply.
Board notes for a two hundred and forty watt stage
The first item is the match impedance. At 50 ohm the peak is 155 V and forces 500 V parts; at 12.5 ohm it is 77.5 V and 250 V ceramics are comfortable. The choice is made before the network is laid out, not after.
The second item is the sink. Fifty three watts continuous is a copper spreader with forced air, and the flange interface is the joint that decides the junction temperature.
The third item is the efficiency at the band edges. The 82 per cent belongs to a tuned point, and the heat budget is checked at 1.4 GHz on the first article.
The fourth item is the drive. Three point eight watts is a single packaged driver on the same board, so the two devices share one sink and one bias reference.
Questions buyers ask about HX13240F
Is 240 W continuous? The mode row reads continuous wave, with 52.7 W of heat to remove.
What is the drive power? 3.80 W at 18 dB of gain, which is 35.80 dBm.
Is it the same device as the 470 W part? Not stated. The rows are identical apart from the output, and the factory answer is what settles whether it is the same die at a lower rating.
Why is the efficiency 82 per cent here and 55 per cent on the 5 GHz parts? Because this is a DC to 1.4 GHz device on 48 V. Efficiency falls with frequency and rises with rail voltage, and both effects are in play across the shelf.
How do we start? Send the band, the output at the connector, the signal, the ambient and the rail. We will quote from the schedule and ship a sample with gain and efficiency measured at 100 MHz, the band centre and 1.4 GHz.