REF195GSZ
Product Specifications
REF195GSZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The REF195GSZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
REF195GSZ: the widest grade of the 5.0 V reference
The REF195GSZ is the G grade of the 5.0 V REF19x reference: plus or minus 10 millivolts initial accuracy and a 25 ppm per degree C maximum temperature coefficient, with the 30 milliamp output and 45 microamp supply current of the family. It is the grade to specify when the system calibrates the whole channel rather than the reference alone.
Published values
| Parameter | Value |
|---|---|
| Output voltage | 5.000 V |
| Grade | G, plus or minus 10 millivolts initial accuracy |
| Temperature coefficient | 25 ppm per degree C maximum |
| Test supply | 5.50 V |
| Supply current | 45 microamps maximum |
| Output current | 30 milliamps |
| Sleep current | 15 microamps maximum |
| Package | 8 lead SOIC_N |
| Temperature tables | minus 40 to plus 85 and minus 40 to plus 125 degrees C |
25 ppm per degree C is 3.1 millivolts over the industrial span
Over 125 degrees the drift term is 3125 ppm, which is 15.6 millivolts on 5 V. That is larger than the 10 millivolt initial error, so the G grade is a part whose error over temperature is dominated by drift rather than by its starting point.
For a system that calibrates at 25 degrees C and then runs cold or hot, that drift is the term to budget. For a system that calibrates at the operating temperature, the drift between calibrations is what matters, and it is smaller.
Where a 10 millivolt 5 V source is the right choice
On a 10 bit converter, one bit of a 5 V full scale is 4.9 millivolts, so 10 millivolts is two bits and the reference is not the limiting error. On a 12 bit converter it is four bits, which is still small against a typical converter's 1 to 2 bit linearity error.
The G grade is therefore a monitoring and control part. It is also common in circuits where the reference sets a threshold rather than a scale, such as a comparator trip point, where 10 millivolts of 5 V is 0.2 percent and the comparator's own offset is comparable.
Same pinout, same package, different grade
All three grades of the 5.0 V member share the 8 lead SOIC and the same pinout, which is what makes a grade upgrade a purchasing change rather than a board change. That is useful during a shortage: a G grade can be fitted where the system tolerates the wider initial error, and the E grade can be resumed when it returns.
The 5.50 V supply requirement is unchanged across the grades. A board that cannot supply 5.5 V cannot use any of them, at any grade.
Reference cover and cross checks
When an order code in this family cannot be found, the ADC and DAC cross reference lists what else does the same job, BOM shortage recovery covers what to check before a part is dropped into an existing board, and component lead time solutions is the route we take on a live shortage.
Two questions buyers ask
Can a G grade be substituted for an E grade on the same board? Electrically the pinout and the function match, so the board will work. The accuracy changes from 2 to 10 millivolts and the drift from 5 to 25 ppm per degree C, so the substitution is valid only if the system's error budget and its calibration routine tolerate the wider numbers.
What is the minimum supply for this part? 5.50 V, which is the condition the electrical tables are written at. The output is 5.0 V, so the half volt is the dropout and the margin together, and a 5 V rail is not enough.