MAX9610HEXK+T
Product Specifications
MAX9610HEXK+T
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The MAX9610HEXK+T from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
MAX9610HEXK+T: One Microamp of Supply for a 100 V/V High Side Sense
The MAX9610HEXK+T is a high side current sense amplifier from Analog Devices in a 5-pin SC70, with the same die offered in a 1 mm by 1.5 mm micro DFN. Supply current is 1 microamp maximum, input offset voltage is 500 microvolts maximum, gain error is below 0.5 percent maximum, and the input common mode range is 1.6 V to 5.5 V. The output is a voltage and three gain versions are available: 25 V per volt on the T, 50 on the F and 100 on the H. The part is specified from -40 C to +85 C and is aimed at single-cell lithium-ion equipment, where the rail is 4.2 V at full charge, about 3.6 V in normal use and below 2.9 V when the cell needs charging.
A 500 microvolt offset is 2 percent of a 25 millivolt full scale
The data sheet recommends a 25 mV to 50 mV full scale sense voltage so the drop across the sense resistor stays small. At a 25 mV full scale the 500 microvolt offset is 2 percent of reading, and at 50 mV it is 1 percent. A 2 percent current error is fine for a fuel gauge that is calibrated against coulomb counting and too coarse for a protection threshold, so the choice of full scale is the accuracy decision. The gain error of 0.5 percent adds to it, and on the H version a 1 A reading can be 5 mA high or low from gain alone before the offset term is counted. Reading the offset as a percentage of the actual current at light load is where the error is worst: at 100 mA with a 50 mV full scale, 500 microvolts is 10 percent.
The sense resistor is chosen backwards from the output range
With a gain of 100, a 25 mV sense voltage becomes 2.5 V and a 50 mV sense voltage becomes 5.0 V, so the amplifier's output range sets the maximum sense voltage and the sense resistor follows from the current to be measured. At 1 A and 50 mV the resistor is 50 milliohms and dissipates 50 mW; at 2 A and 50 mV it is 25 milliohms and dissipates 100 mW. A 50 mW loss in a battery path is 5 percent of a 1 W budget, which is why the lower full scale exists: 25 mV halves both the loss and the signal. On the H version the 2.5 V output for a 25 mV sense sits in the middle of a 3.3 V converter's range, which is the version to pick when the monitor shares an ADC with other signals.
One microamp over a year is 8.8 mAh
Eight and eight tenths milliamp hours is small against a 1000 mAh cell, and it is the reason this class of amplifier can stay connected to the cell permanently rather than being switched by the processor. The comparison that matters is with the alternative: a shunt monitor built from an op amp and four resistors draws a few tens of microamps and needs a rail that is present, while this part draws one microamp from the rail it is measuring. In a product that sits on a shelf for a year before it is sold, that difference is the difference between a cell that still has a charge and one that does not.
| Parameter | Published value | What it decides |
|---|---|---|
| Supply current | 1 uA maximum | 8.8 mAh over a year |
| Offset voltage | 500 uV maximum | 2 percent at a 25 mV full scale |
| Gain error | Below 0.5 percent | 5 mA at a 1 A reading |
| Common mode | 1.6 V to 5.5 V | Covers a Li+ cell at 4.2 V and 2.9 V |
| Gain, H version | 100 V per volt | 25 mV in becomes 2.5 V out |
| Gain, F version | 50 V per volt | 50 mV in becomes 2.5 V out |
| Gain, T version | 25 V per volt | 100 mV in becomes 2.5 V out |
| Sense at 1 A | 50 milliohm for 50 mV | 50 mW of loss |
| Package | 5-pin SC70 or 1 by 1.5 mm DFN | Fits inside a battery connector footprint |
| Temperature | -40 C to +85 C | Consumer and industrial, not 125 C |
Does the 1.6 V to 5.5 V common mode cover a lithium-ion cell?
Yes, and that is what the range was chosen for. A single cell is 4.2 V at full charge, 3.6 V nominal and below 2.9 V at the point where the product should shut down, and all three sit inside 1.6 V to 5.5 V. Two cells in series reach 8.4 V and are outside the range, so a two-cell pack needs a different part rather than a divider on the sense input. The 5.5 V top also rules out a 5 V rail that can sit at 5.5 V plus tolerance, which is a real case on a USB input.
Why gain 100 rather than 50?
Because the output has to reach a useful level from the smallest sense voltage the accuracy allows. At a 25 mV full scale the H version gives 2.5 V, the F gives 1.25 V and the T gives 0.625 V. On a 3.3 V converter with a 3.3 V reference the H version uses 76 percent of the range and the T version uses 19 percent, so the same converter resolution buys four times less resolution in current. The cost of the higher gain is that the output saturates earlier: 50 mV of sense voltage at a gain of 100 is 5 V, which is above a 3.3 V rail, so the H version pairs with a 25 mV full scale and the T version with a 100 mV one. Choosing the gain and the sense resistor together is the whole exercise. Related monitors are listed on the power management cross reference, pin and package comparisons across the family are on the pin to pin cross reference, and the full category is the analog and mixed-signal index.
Request Quote — In Stock, 100% New & Original, Full Warranty