Contact Us

MAX8211ESA+T

Brand: Analog Devices
Analog Devices MAX8211ESA+T is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

MAX8211ESA+T — Analog & Mixed-Signal ICs | Superb Automation

MAX8211ESA+T

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The MAX8211ESA+T from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

MAX8211ESA+T: Five Microamps of Detector and a Divider That Draws Twice as Much

The MAX8211ESA+T is a CMOS micropower voltage detector in an 8-lead SO package that contains a comparator, a 1.15 V bandgap reference and an open drain n-channel output driver, with a second output that provides hysteresis. Two external resistors set the trip point against the internal reference, the supply range is 2.0 V to 16.5 V, quiescent current is 5 uA, threshold accuracy is plus or minus 40 mV or plus or minus 3.5 percent, and the output sinks up to 7 mA with current limiting on this member. The MAX8212 is the same part with a non limited output and a non inverting sense, and both are drop in replacements for the bipolar ICL8211 and ICL8212 below 16.5 V.

The part is a power fail warning for a processor: it watches a rail through a divider and pulls an interrupt when the rail falls, early enough for the processor to save its state. The 5 uA is what makes it viable in a battery product, and the divider is what usually doubles the real current.

Two hundred and ninety one kilo-ohms plus one hundred draws eleven point five microamps

To trip at 4.5 V the divider ratio has to be 1.15 divided by 4.5, which is 0.2556: a 291 kOhm upper resistor and a 100 kOhm lower resistor give 0.2558. The current through that pair at 4.5 V is 11.5 uA, which is 2.3 times the 5 uA the part itself draws. So the monitoring function costs 16.5 uA in total, not 5 uA, and a board that budgets the data sheet figure is out by more than a factor of two. Larger resistors reduce the divider current and increase the error from the input bias current and from noise, so there is a floor set by the part's own input characteristics.

The plus or minus 3.5 percent threshold accuracy is plus or minus 40 mV at the 1.15 V reference, and through the 0.2556 divider that becomes plus or minus 157 mV at a 4.5 V trip point. That is 3.5 percent of the rail, which is fine for a warning and marginal for a cutoff: a processor that must stop before its regulator drops out needs the warning to arrive with more margin than the detector's own uncertainty.

Reference1.15 V bandgap, plus or minus 40 mV, plus or minus 3.5 percent
Trip error at 4.5 VPlus or minus 157 mV through a 0.2556 divider
Divider for 4.5 V291 kOhm and 100 kOhm, 11.5 uA at the trip point
Total monitoring current16.5 uA, 2.3 times the part current alone
Part current5 uA, 25 uW at 5 V, 43.8 mAh over a year
Supply range2.0 V to 16.5 V
OutputOpen drain, 7 mA current limited on the MAX8211, unlimited on the MAX8212
HysteresisA second output for positive feedback, so the trip and release points differ
Package8-lead SO, also DIP in the family

Two volts is the floor, and 16.5 V is the ceiling

The 2.0 V minimum supply rules out monitoring a 1.8 V rail with this part, which is the one direction the market has moved since the ICL8211 was introduced. The 16.5 V ceiling means a 24 V rail needs a divider that brings the tap below 16.5 V, which is easy, but the part itself cannot be powered from the rail it is watching above that voltage. A 12 V rail is inside the range and needs no separate supply.

The hysteresis output is what keeps the detector from chattering. Without it, a rail that sags slowly through the trip point produces a burst of interrupts as noise moves the tap back and forth, and the processor spends its last microseconds servicing interrupts instead of saving state. Positive feedback through the hysteresis output moves the release point, so the warning is asserted at one voltage and released at a higher one.

Two questions buyers ask

Can it replace an ICL8211 directly?
Yes, below 16.5 V, with the same pinout and the same two resistor trip network. What improves is the supply current, the reference tolerance and the available current from the hysteresis output; what does not change is the 1.15 V reference, so the divider values carry over unchanged. Above 16.5 V the bipolar part remains the only option in that footprint.

What is the difference between the MAX8211 and the MAX8212?
The output drive and the sense polarity. The MAX8211 sinks a current limited 7 mA when the threshold pin is below the reference, which suits a pull up to a logic rail; the MAX8212 turns its output on when the pin is above the reference and has no current limit, which suits driving a load directly. They are not interchangeable in a circuit, because both the polarity and the load capability change.

Ordering and supply

The ESA suffix is the 8-lead SO package in tape and reel. Substitution traps are the reference voltage, the sense polarity and the output type: a detector with a 1.25 V reference needs a different divider, an inverted sense turns the warning into an enable, and an open drain output with no pull up reads as a permanent warning. All three differences are invisible in a description that only says voltage detector.

We hold and source this family for production and repair lots. Start at the analog mixed signal ICs family page, compare a candidate against the power management cross reference, and where a detector has to be changed on a built board, the order in how to verify a drop in replacement puts the reference and the divider first.

Request Quote — In Stock, 100% New & Original, Full Warranty