MAX6610AUT+T
Product Specifications
MAX6610AUT+T
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The MAX6610AUT+T from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
MAX6610AUT+T: a 2.560 V Reference That Also Reports Temperature
The MAX6610AUT+T combines a precision voltage reference and a calibrated analog temperature sensor in a 6-pin SOT23 from Analog Devices. It runs from 3.0 V to 5.5 V and puts out a 2.560 V reference, while its temperature output is scaled so that a converter using the same 2.560 V reference reads temperature directly: one LSB of an 8-bit converter is 1 C, and one LSB of a 10-bit converter is 0.25 C. Accuracy is plus or minus 1 C, reference temperature coefficient is 10 ppm per C typical, supply current is under 150 uA, and the part operates from -40 C to +125 C with no calibration step. A low current shutdown mode is provided.
10 mV per degree is what makes the converter read degrees
The temperature output moves 10 mV per degree C. Because the reference and the sensor share one die, a converter that also uses the 2.560 V output as its own reference measures a ratio, and the absolute value of the reference cancels in the conversion. That is the point of pairing the two functions in one package: the reading depends on the ratio of two on-chip quantities, not on the accuracy of an external reference. A circuit that uses a different reference loses that cancellation and inherits both errors.
Reference drift spends 0.42 C of the plus or minus 1 C budget
A 10 ppm per C typical coefficient across the full 165 C span is 1650 ppm, which is 4.22 mV on a 2.560 V output, and at 10 mV per degree that is 0.42 C. The plus or minus 1 C accuracy figure is therefore not free: almost half of it can be spent before the sensor's own error is counted. The typical coefficient is also not the maximum, so a worst case part drifts further. For an application that needs 0.5 C absolute accuracy over temperature the part is the wrong choice; for one that needs a repeatable reading and a coarse absolute check, the ratio measurement is adequate.
The 4.096 V version needs a 4.5 V rail, the 2.560 V version does not
The MAX6611 in the same family outputs 4.096 V but needs 4.5 V to 5.5 V at the input, so a 3.3 V system cannot use it and has no path to a 4.096 V full scale from this family. The MAX6610 accepts 3.0 V to 5.5 V, which covers a 3.3 V rail with 300 mV to spare and a 5 V rail with 2.44 V of headroom. Supply current of 150 uA is 0.75 mW at 5 V and 0.49 mW at 3.3 V. Related converter options are listed on the ADC and DAC cross reference.
| Parameter | Published value | What it decides |
|---|---|---|
| Reference output | 2.560 V | 8-bit LSB 10 mV, 10-bit LSB 2.5 mV |
| Temperature scale | 10 mV per C | 1 C per 8-bit code, 0.25 C per 10-bit code |
| Accuracy | Plus or minus 1 C | 0.42 C of it is available to reference drift |
| Reference drift | 10 ppm per C typical | 4.22 mV over 165 C |
| Supply range | 3.0 V to 5.5 V | Runs from 3.3 V; the 4.096 V version does not |
| Supply current | Under 150 uA | 0.49 mW at 3.3 V |
| Package and range | 6-pin SOT23, -40 C to +125 C | No calibration step in production |
Can it be used as a plain voltage reference without the temperature output?
Yes, and the temperature pin can be left unconnected if the converter does not need it, but the reference then has to be judged on the 10 ppm per C typical coefficient alone, which is not a precision class part. A system that needs 2.560 V at better than 0.1 percent over temperature should use a dedicated reference. The part earns its place when the same converter has to read both a sensor bridge and a board temperature.
What does a 100 C span look like in codes?
At 10 mV per degree, a 100 C span is 1.0 V of output swing and 100 codes out of the 256 that an 8-bit converter provides, so the resolution is coarse but the scale factor is exact and needs no calibration table. The wider catalogue of temperature and reference parts is on the analog and mixed-signal index, and the power side of the same board is covered on the power management cross reference.
MAX6610AUT+T: why 2.560 V is the right reference for a temperature channel
The reference is 2.560 V because the temperature output is scaled at 10 mV per degree, and 2.560 V divides exactly into the code space of an 8 bit and a 10 bit converter. On 8 bits one code is 10 mV, which is 1 degree. On 10 bits one code is 2.5 mV, which is 0.25 degree. On 12 bits one code is 0.625 mV, which is 0.0625 degree. All three are arithmetic on the quoted 10 mV per degree and the quoted reference value, and the point of the arrangement is that the converter reads degrees directly with no calibration table and no firmware scale factor. A 4.096 V reference with the same sensor would put 39 codes per degree and force a multiplication in software.
The 3.0 V floor, and the rail it rules out
The MAX6610 runs from 3.0 V to 5.5 V and the MAX6611 from 4.5 V to 5.5 V. A 3.3 V rail at minus 5 percent is 3.135 V, so it sits inside the window with 135 mV to spare; a 3.3 V rail at minus 10 percent is 2.97 V and is outside it. A 2.5 V rail never works with either version, which is worth stating because a 2.5 V sensor bus is common. Supply current under 150 uA at 3.3 V is 0.495 mW, so an always-on temperature channel costs about 4.3 Wh over a year, which is the kind of number that decides whether a battery product can leave it powered.
| Item | Published value | What it decides |
|---|---|---|
| Reference output | 2.560 V, or 4.096 V in the MAX6611 | Full scale for the converter and the code per degree |
| Temperature scale | 10 mV per degree | 1 degree per code at 8 bits, 0.25 at 10 bits |
| Accuracy | Plus or minus 1 C | The converter resolution does not improve this figure |
| Reference drift | Plus or minus 10 ppm per C, typical | 0.165 percent over 165 C, which is 4.2 mV |
| Supply | 3.0 V to 5.5 V | A 3.3 V rail at minus 10 percent is outside |
| Supply current | Under 150 uA | 0.495 mW at 3.3 V, 4.3 Wh over a year |
| Package | 6-pin SOT23 | One part for reference and sensor, no second footprint |
Resolution is not accuracy, and this part makes that obvious
A 10 bit converter reading this output resolves 0.25 degree per code while the sensor is guaranteed to plus or minus 1 degree. The extra two bits of resolution are useful for averaging and for seeing a trend, and they do not make the absolute reading better than the 1 degree limit. That split is the reason a calibration step at the instrument level still exists on most boards that use this part, and the reason the vendor describes the part as needing no calibration rather than as being accurate to a quarter of a degree.
Converters that pair with this reference are compared on the ADC and DAC cross reference, the rest of the sensor and reference line is on the analog and mixed-signal ICs page, and a stock position for a small SOT23 sensor is on BOM shortage recovery.
Request Quote — In Stock, 100% New & Original, Full Warranty