LTM8078IY#PBF
Product Specifications
LTM8078IY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8078IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8078IY: two 1.4 A rails in 39 square millimetres, and the real thermal budget
The LTM8078IY#PBF is a 40 V dual step-down module from the Analog Devices Silent Switcher family, in a 6.25 mm by 6.25 mm by 2.22 mm ball grid array. Each channel delivers 1.4 A at 24 V in and 3.3 V out with an 85 degree ambient, and the two channels can be paralleled into a single 2.8 A output. The controller, the switches, both inductors and the support parts sit inside the package, so the only external parts on the bill are the bulk input and output capacitors and one resistor per channel to set frequency. The I suffix sets the guaranteed range at -40 to +125 degrees internal, and the module carries 49 balls on a 0.8 mm pitch.
Published values
| Parameter | Value |
|---|---|
| Input range | 3 V to 40 V on VIN1; VIN2 starts at 2 V once VIN1 is at 3 V |
| Output range | 0.8 V to 10 V per channel, set by the feedback divider |
| Continuous current | 1.4 A per channel at 24 V in, 3.3 V out, 85 degree ambient; 2.8 A with the channels in parallel |
| Current limit | 2.5 A maximum output DC current per channel |
| Switching frequency | 300 kHz to 3 MHz; RT of 113k gives 300 kHz, 30.9k gives 1 MHz, 7.15k gives 3 MHz |
| Feedback voltage | 800 mV nominal, 792 mV to 808 mV at 25 degrees, 784 mV to 816 mV over the full range |
| Line and load regulation | 0.1 percent and 0.2 percent |
| Output ripple | 10 mV RMS at 3.3 V out |
| Shutdown current | 2 mA typical, 4 mA maximum into VIN with RUN at 0 V |
| No load current | 60 mA with SYNC low, 10 mA with SYNC at 3.3 V, both with BIAS at 5 V |
| Power good window | trips at 740 mV rising and 860 mV falling on an 800 mV reference, plus or minus 7.5 percent |
| Soft start | 2 microamps out of TRSS, 170 ohm pull down on a fault |
| Package | 49 ball BGA, 6.25 mm by 6.25 mm by 2.22 mm, MSL 3 |
| Thermal | 31.3 degrees per watt junction to ambient, 10.6 degrees per watt junction to board |
| Temperature grade | -40 to +125 degrees internal, TJ maximum 125 degrees |
The 1.4 A figure has a temperature attached to it
Two channels at 1.4 A and 3.3 V is 9.24 W of output. At an 85 degree ambient the junction has 40 degrees of headroom to the 125 degree limit, which through 31.3 degrees per watt is 1.28 W of total dissipation, or 0.64 W per channel. That means each channel has to run at 87.8 percent efficiency to hold its rating in still air: 4.62 W out against 0.64 W of loss.
At 5 V out the same 1.4 A is 7 W per channel, so the efficiency floor drops to 91.6 percent and the number gets harder, not easier. A 24 V to 5 V conversion at 1 MHz sits near that line, which is why the data sheet quotes the current at 3.3 V out. Any build that runs 5 V or 10 V out at full current on an 85 degree board should be checked against the derating curves rather than the front page.
Two channels out of phase, and when to parallel them instead
The two channels switch on a shared clock and can be locked 180 degrees apart, which halves the input ripple current that the bulk capacitor has to absorb. On a 24 V backplane that is the difference between two 10 microfarad ceramics and a bank, and it also keeps the two rails from beating against each other when both feed the same intermediate bus.
Paralleling to 2.8 A is a different move: the outputs are tied, one feedback divider drives both channels, and the internal current sharing balances the two power stages. The trap is that the current limit stays per channel at 2.5 A, so a 2.8 A load is protected at 5 A total, which is enough to sit in overload for a long time before the thermal path notices. Set the load expectation from the thermal budget above, not from the limit.
What the I grade changes, and what it does not
The I suffix is the same silicon tested over -40 to +125 degrees internal, with the data sheet limits guaranteed across that window rather than from 0 degrees. It does not change the maximum junction temperature, the current rating or the thermal resistance, and it does not make the part run cooler. What it buys is a guarantee at cold start, which matters for outdoor cabinets and for equipment that is stored unheated.
Finish is the other field on the order line. The IY#PBF is SAC305 with a nickel gold pad, MSL 3, 168 hours of floor life. The same code without the #PBF suffix is tin lead, and the IY#3PP adds the automotive flow with AEC-Q104 grade 2, which only exists on the I grade because the qualification has to cover -40 degrees.
When an order code in this family cannot be found, the power management cross reference lists what else does the same job, the pin to pin cross reference covers what to check before a part is dropped into an existing board, and component lead time solutions is the route we take on a live shortage.
Two questions buyers ask about this rail
Can the two channels run at different frequencies? No. There is one oscillator, set by RT, and both channels switch from it. The channels can be phased apart with the CLKOUT and SYNC pins, and the whole module can be locked to an external clock between 300 kHz and 3 MHz, but two independent frequencies need two modules.
Is 2 mA of shutdown current normal for a module this size? It is the published figure for RUN at 0 V, and it is 17.5 Ah over a year, which is a real number on a battery product. If the rail only needs to be off for short intervals, dropping the RUN pin from the host is cheaper than adding a load switch, but a long storage interval needs the input disconnected.