Contact Us

LTM8058MPY#PBF

Brand: Analog Devices
Analog Devices LTM8058MPY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8058MPY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8058MPY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8058MPY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8058MPY: an isolated rail plus a 20 microvolt post regulator, to -55 degrees

The LTM8058MPY#PBF is the extended temperature member of the isolated flyback module that carries an LDO after the transformer: 3.1 V to 31 V in, an isolated 2.5 V to 13 V first output rated up to 440 mA, and a second output from the linear post regulator, 1.2 V to 12 V at up to 300 mA. The 2 kVAC barrier is tested at 3 kVDC for one second and recognised under UL60950 file E464570. The MP grade is guaranteed over -55 to +125 degrees internal, which is the code for instrumentation that has to be specified at the temperature extremes rather than merely survive them.

Published values

ParameterValue
Input range3.1 V to 31 V with BIAS tied to VIN; 4.3 V minimum with BIAS open
First output2.5 V to 13 V, up to 440 mA at 24 V in and 2.5 V out
Post regulator output1.2 V to 12 V, up to 300 mA
Sum ruleVIN plus VOUT1 limited to 36 V in total
Isolation2 kVAC, tested at 3 kVDC for one second, UL60950 file E464570
Post regulator dropout0.25 V at 10 mA, 0.34 V at 100 mA, 0.43 V at 300 mA
Post regulator noise20 microvolts RMS with a 0.01 microfarad bypass, 100 Hz to 100 kHz
First output regulation1.7 percent line, 1.5 percent load, 20 mV RMS ripple
Post regulator regulation1 mV to 5 mV line, 2 mV to 10 mV load
Quiescent current1 microamp with RUN at 0 V, 850 microamps not switching
RUN threshold1.24 V rising typical, 1.18 V to 1.30 V guaranteed
Output short circuit30 mA of input current with the first output shorted
Package38 pin BGA, 11.25 mm by 9 mm by 4.92 mm, 1.1 g
Thermal23.2 degrees per watt to ambient, 5.8 to the board
Temperature grade-55 to +125 degrees internal, guaranteed by test over the full range

The sum rule sets the highest usable output

VIN plus VOUT1 is limited to 36 V, measured as (VIN - GND) plus (VOUT1 - VOUT minus). At 24 V in the highest first output is 12 V; at 31 V in it is 5 V. A 24 V input with a 13 V output is 37 V and outside the rating by one volt, which is the kind of margin that disappears when the input is a nominal 24 V battery that charges to 28 V.

The post regulator inherits the same rule. It only sees VOUT1, but it has to sit at least 0.43 V above its own output at 300 mA, so a 12 V first output gives a 12 V LDO output almost no headroom, and a 5 V LDO output from a 5 V first output drops out entirely.

Two regulators in one package and one thermal budget

The junction temperature is shared. At 5 V in and a 3.3 V LDO output at 300 mA, the post regulator alone dissipates 0.51 W, and the flyback that feeds it adds its own loss. Both flow through the same 23.2 degrees per watt to ambient, so a rail that looks like two easy jobs is one thermal problem, and the LDO is usually the larger of the two terms because it is a linear stage.

The way to move heat out of the LDO is to lower the first output, not to add a heatsink. Setting VOUT1 to 3.8 V instead of 5 V cuts the LDO dissipation from 0.51 W to 0.15 W, as long as the flyback can still hold regulation and the 0.43 V dropout is respected.

Why the post regulator is worth having

A flyback's output ripple is set by the transformer and the output capacitor, and 20 mV RMS is typical. The LDO takes that down to 20 microvolts RMS between 100 Hz and 100 kHz with a 0.01 microfarad bypass, which is three orders of magnitude, and it does it after the isolation barrier, so the quiet rail is on the isolated side where the sensor or the converter sits.

That is the difference between a rail that can feed a 16 bit converter and one that cannot. It is also why this part exists alongside the plain isolated module: the two are not interchangeable when the load is analogue.

Buyers usually arrive at the power management cross reference to find the family alternatives, then use medical device components to confirm a substitute before it is fitted; the pin to pin cross reference is the routine for a part that has already stopped shipping.

Two questions buyers ask about the MP grade

Is -55 degrees a tested or a characterised number? The order table guarantees the MP grade over -55 to +125 degrees internal, and the note states that the E and I grades are tested from 0 and -40 respectively. The MP is the only grade in this family with a full range guarantee at the cold end.

Can both outputs be loaded at the same time? Yes, but they share the junction temperature. Add the flyback loss and the LDO loss, multiply by 23.2 degrees per watt, and check the result against the ambient. The 440 mA and 300 mA ratings are each stated alone.