ADR5041BRTZ
Product Specifications
ADR5041BRTZ
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The ADR5041BRTZ from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ADR5041BRTZ: A 0.2 Percent Reference Whose Drift Is Eight Times Its Initial Error
The ADR5041 is a 2.500 V shunt reference in a three lead SOT-23 or SC70, with a 50 uA to 15 mA operating current range, 0.1 percent initial accuracy on the A grade and 0.2 percent on the B grade, and a specified temperature coefficient of 75 ppm per degree C maximum on the A grade and 100 ppm per degree C maximum on the B grade. The B code on this page is the cheaper of the two, and the arithmetic that decides whether it is good enough is not the initial accuracy but the drift over the range the product is specified for.
Drift against initial error
On 2.5 V, 0.2 percent is 5 mV and 0.1 percent is 2.5 mV. A 100 ppm per degree C coefficient over the minus 40 C to plus 125 C range, which is a 165 degree span, is 16,500 ppm or 1.65 percent, which is 41.3 mV. The same span at 75 ppm per degree C is 31 mV. Both numbers are an order of magnitude above the initial accuracy of either grade, so a customer comparing the two grades on the 0.1 percent line is comparing the wrong column. Unless the board is trimmed at temperature, the drift sets the accuracy and the A grade buys about 10 mV of it back.
It is a shunt, so the resistor is part of the error
A shunt reference sinks its own current plus the load, and the series resistor has to supply the minimum operating current of 50 uA at 25 C and 60 uA over temperature at the lowest supply voltage. From a 5 V rail into a 2.5 V reference with a 1 mA load, a 2.2 kohm resistor leaves 1.14 mA at nominal and 0.87 mA with the rail five percent low, both above the 60 uA floor. The same resistor at 15 mA of load is impossible, and the 15 mA figure is the maximum the reference can sink rather than a load it can drive.
| Item | Published value | What it decides |
|---|---|---|
| Output | 2.500 V | Fixed, no divider |
| Initial accuracy | 0.1 percent A, 0.2 percent B | 2.5 mV against 5 mV |
| Drift | 75 ppm per C A, 100 ppm per C B | 31 mV against 41 mV over 165 C |
| Operating current | 50 uA to 15 mA, 60 uA minimum over temperature | Sets the series resistor |
| Output noise | 2.8 uV peak to peak, 0.1 to 10 Hz | 4 percent of a 16 bit LSB on 2.5 V |
Noise and hysteresis
The low frequency noise is 2.8 uV peak to peak from 0.1 Hz to 10 Hz and 120 uV rms from 10 Hz to 10 kHz. On a 2.5 V full scale a 16 bit LSB is 38 uV, so the low frequency noise is a small fraction of one count and the wideband figure is about three counts. Output voltage hysteresis is 40 ppm, which is 100 uV, so a thermal cycle during reflow moves the output by about three counts and the reference should not be expected to hold a calibration across assembly without a trim step.
Where the part earns its place
The three lead package and the 50 uA floor make this a reference for a converter that runs from the same rail, a comparator threshold, or a bias point that has to survive a wide temperature range without a heater. It is not a candidate for a 16 bit absolute measurement over temperature without calibration, because 41 mV of drift on 2.5 V is 1,080 counts of a 16 bit converter at full scale. Where the requirement is absolute accuracy, the answer is a buried zener or a heated reference and a different budget.
Grade and sourcing notes
The A and B codes are the same die with a tighter test, so a line that has validated the B grade at temperature can move to the A grade without a requalification, and the reverse move is the one that needs a check. The ADC DAC cross reference page covers the converters this reference usually feeds, the ADI part second source page covers the grade question, and lot checks follow the incoming inspection plan.