LTM8055EY#PBF
Product Specifications
LTM8055EY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8055EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8055EY: a 36 V buck-boost for 0 to 125 degree equipment
The LTM8055EY#PBF is the commercial grade of the 36 V, 8.5 A buck-boost module, in a 15 mm by 15 mm by 4.92 mm package, with the output allowed above, equal to or below the input and a range of 1.2 V to 36 V. The E grade is guaranteed from 0 to +125 degrees internal, with the -40 degree end assured by characterisation rather than by test, and the -55 degree MP grade is a separate code. For a mains powered instrument or a rack unit whose ambient specification starts at 5 degrees, the electrical table is identical and the qualification trail is shorter.
Published values
| Parameter | Value |
|---|---|
| Input range | 5 V to 36 V |
| Output range | 1.2 V to 36 V, any relationship to the input |
| Output current | 3 A at 6 V in and 12 V out; 8.5 A at 24 V in and 12 V out |
| Efficiency | up to 97.5 percent |
| Switching frequency | 100 kHz to 800 kHz |
| Feedback voltage | 1.2 V nominal |
| Input and output current limits | adjustable, 56 mV and 61.5 mV sense thresholds |
| Quiescent current | 0.1 microamp typical with RUN low |
| No load current | 8 mA discontinuous, 45 mA forced continuous |
| Line and load regulation | 0.5 percent and 0.5 percent |
| Output ripple | 25 mV RMS |
| Guaranteed range | 0 to +125 degrees internal by test |
| Package | 121 lead BGA, 15 mm by 15 mm by 4.92 mm |
| Thermal | 20.5 degrees per watt to ambient, 11.0 to the board |
A 12 V rail from a 24 V bus in a rack
In a rack the bus is well regulated and the buck-boost is doing a buck job almost all the time. What it buys over a plain buck is the ability to hold 12 V if the bus dips to 8 or 9 V during a changeover, which on a redundant supply is a routine event and on a single supply is the difference between a reset and a ride through.
The thermal arithmetic is the same as the industrial code: 102 W out at 8.5 A, 2.6 W of loss, a 53 degree rise, so the load has to come down or the airflow has to go up before an 85 degree ambient is survivable. In a rack with 40 degree inlet air and a fan, the margin is comfortable.
Forced continuous or discontinuous
The mode pin selects between discontinuous conduction, which drops the no-load input current to 8 mA, and forced continuous, which keeps the inductor current flowing and the switching frequency fixed at 45 mA of housekeeping current. Discontinuous is the right choice for a rail that idles; forced continuous is the right choice when ripple and loop behaviour matter more than standby, for example when the output feeds a converter that is itself sensitive to a variable frequency.
The mode cannot be changed at run time without care, because the loop compensation and the output ripple both change with it. Pick one at build and set it with a strap, not with a processor pin.
What the E grade means for the supply chain
The E, I and MP codes share the die, the package and the external components. If the industrial code is on allocation, the commercial code is a legitimate substitute for indoor equipment once the temperature note on the drawing is changed, and the MP code covers the cold end where the product claims it.
The trap is a drawing that lists the E grade while the product claims -20 degrees. That combination exists in the field more often than it should, and the fix is to read the temperature line of the specification against the grade on the order code, not against the family name.
Two pages worth reading before a purchase order goes out are the power management cross reference and vendor consolidation; the first lists what else fits the socket, the second is the test sequence for a drop in, and component lead time solutions covers the case where the shortage is already on the line.
Two questions buyers ask about the E grade
Is the E grade's -40 degree figure tested? The order table prints -40 to +125, but the note states the E grade is guaranteed from 0 degrees with the rest of the range assured by characterisation. The I grade is the tested -40 code.
Does the output current rating depend on the mode? The current ratings are quoted at the published operating conditions and are limited by the thermal path in still air. Changing conduction mode changes the loss slightly, not the rating.