Contact Us

LTM8054EY#PBF

Brand: Analog Devices
Analog Devices LTM8054EY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8054EY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8054EY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8054EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8054EY: the 5.4 A buck-boost for controlled ambients

The LTM8054EY#PBF is the commercial grade of the 36 V, 5.4 A buck-boost module, 11.25 mm by 15 mm by 3.42 mm, with a 1.2 V to 36 V output that may sit above, at or below the input. The E grade is guaranteed from 0 to +125 degrees internal, with the colder part of the printed range assured by characterisation. The module carries the same adjustable input and output current limits, the same 1.2 V reference and the same 17.6 degrees per watt thermal path as the industrial code, so the choice between them is a documentation question rather than an electrical one.

Published values

ParameterValue
Input range5 V to 36 V
Output range1.2 V to 36 V
Output current5.4 A at 24 V in and 12 V out; 3.4 A at 12 V in; 1.8 A at 6 V in
Efficiencyup to 94 percent
Switching frequency100 kHz to 800 kHz
Feedback voltage1.2 V nominal
Current limitsadjustable input and output average current
Quiescent current0.1 microamp typical with RUN low
No load current8 mA discontinuous, 45 mA forced continuous
Guaranteed range0 to +125 degrees internal by test
PackageBGA, 11.25 mm by 15 mm by 3.42 mm
Thermal17.6 degrees per watt to ambient, 5.9 to the board

A bench supply that has to survive a 24 V input and hold 12 V

Test equipment often has to run from whatever the customer's site provides, which can be 24 V nominal but 18 V under load and 30 V during a transient. A buck-boost holds the 12 V rail across that entire span, and the 3.42 mm package fits the height budget of a 1U instrument.

The current limit pins are useful here for a different reason: a bench instrument that can be connected to an unknown load wants an adjustable current limit as a feature, not only as protection. The 61.5 mV output sense threshold with a suitable shunt gives a limit that can be dialled from the front panel.

The 0 degree floor and the shipping container

Storage is rated -55 to +125 degrees separately, so transport is not the issue. The issue is the operating specification: an instrument rated 5 to 40 degrees is fully covered by the E grade, and the industrial or MP code adds evidence for a claim the product does not make.

Where a customer's site specification goes to -10 or -20 degrees, the grade has to change. That is a specification decision that should be made once, at the point the product requirements are written, rather than discovered during qualification.

Where the 94 percent figure comes from

The peak efficiency of a buck-boost occurs in buck mode with a moderate step down ratio, and it is a curve rather than a number. Near the transition where VIN equals VOUT the efficiency dips because the converter is passing through a region where the switches are not doing a clean buck or boost job.

Plan the thermal budget from the efficiency at the actual operating point, not from the 94 percent peak. On a 24 V to 12 V rail in still air, 5.4 A needs a 50 degree ambient, and the board's copper is part of the answer.

The pages that answer this most often are how to verify a drop in replacement for the family alternatives, the power management cross reference for the acceptance test, and vendor consolidation for the case where a replacement has to be fitted before the next build.

Two questions buyers ask about the E grade

Is the E grade's -40 degree figure tested? No, the note states the E grade is guaranteed from 0 degrees and the remainder of the range is assured by characterisation and correlation. The I grade is the tested code.

Can the module be synchronised to an external clock? Yes, from 200 kHz to 700 kHz, with a clock output available to drive another module. Running several rails at one frequency keeps the beat products out of a sensitive band.