LTM8049IY#PBF
Product Specifications
LTM8049IY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8049IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8049IY: two SEPIC or inverting rails in a single 15 by 9 mm module
The LTM8049IY#PBF carries two complete switching supplies in one 15 mm by 9 mm by 2.42 mm ball grid array weighing 0.8 g. Each output is configured as a SEPIC or as an inverting converter by grounding the appropriate output rail, so the same module makes plus and minus rails from a single input without a second part number. Input range is 2.6 V to 20 V, each output spans 2.5 V to 24 V or -2.5 V to -24 V, and each side switches from 200 kHz to 2.5 MHz. Both halves have their own power good output, their own soft start and their own undervoltage lockout, which is what makes the pair usable for event based sequencing.
Published values
| Parameter | Value |
|---|---|
| Input range | 2.6 V to 20 V per side; 20 V absolute maximum on VINn |
| Output range | 2.5 V to 24 V positive, -2.5 V to -24 V negative |
| Output current | 1 A at plus or minus 5 V from 12 V in; 0.25 A at plus or minus 24 V |
| Switching frequency | 2.5 MHz with RT at 31.6k, 200 kHz with RT at 412k |
| Feedback, positive output | 1.204 V nominal at FBX, 1.185 V to 1.22 V, with 83.3 microamps out of the pin |
| Feedback, negative output | 7 mV nominal at FBX, 2 mV to 16 mV, with the same pin current |
| Quiescent current | 10 mA at no load, 2 microamps maximum shut down |
| Line and load regulation | 0.1 percent and 0.3 percent |
| RUN thresholds | 1.27 V rising typical, 1.4 V falling typical |
| Thermal | 16.2 degrees per watt junction to ambient, 3.8 to the board, 8.8 to the top |
| Package | 77 lead BGA, 15 mm by 9 mm by 2.42 mm, MSL 3, 0.8 g |
| Assembly | not recommended for second side reflow in the vendor document |
| Status | in production; the industrial code is guaranteed over the full -40 to +125 degree range |
One board, two topologies, and the divider that has to change with them
Grounding VOUT1N turns the first output into a SEPIC, where the regulated voltage can sit above, below or level with the input. Grounding VOUT1P instead turns the same half into an inverting converter and the output swings negative. The two halves are independent, so a board can run a positive SEPIC rail and a negative inverting rail from one module, which is what the typical application does with plus and minus 12 V from a 2.7 V to 20 V input.
The trap is the feedback. A positive output is set against 1.204 V at FBX with 83.3 microamps flowing out of the pin, while a negative output is set against 7 mV with the same current. A divider lifted from the positive case and dropped into the inverting case produces a rail that is nothing like the intended value, and the error looks like a bad module rather than a wrong resistor.
Why the current rating falls so fast as the ratio grows
One amp at 5 V from 12 V is 5 W out, and at an 85 degree ambient the 16.2 degrees per watt path allows about 2.47 W of dissipation, so the thermal budget only asks for 67 percent efficiency. Move to 24 V at 0.25 A and the output is 6 W, which would need 71 percent efficiency against the same budget, so the heat is still not the limit. What limits it is the conversion ratio: the switch current and the inductor ripple inside the module set the ceiling, and that is why the data sheet quotes a quarter of an amp at the top of the range.
The useful rule for a quoting conversation is that the pair behaves like two small converters, not like one large one. Two rails at 12 V and 0.5 A each are comfortable from a 5 V input; one rail at 24 V and 1 A is not a configuration this part supports at any input.
Sequencing, and the handling rule that is easy to miss
Each half has a power good output and a clock output, so one rail can be held until the other reports good, and the two halves can be locked to a common clock with a phase offset to keep the input ripple from adding. The soft start pins are separate as well, which matters when a large output capacitance on one rail would otherwise hold the other down at start-up.
The vendor document states that the module is not recommended for second side reflow. That is a process note, not a performance note: a board that needs parts on both sides has to put this one on the primary side and reflow the second side with a profile that does not reflow the first. MSL 3 floor life and the 260 degree maximum solder temperature apply on top of that.
Where a customer needs a second position on this part, the power management cross reference is the starting point, how to verify a drop in replacement sets out the checks a substitution has to pass, and OEM procurement is the short lead time route we quote against.
Two questions buyers ask about the dual module
Can one output be SEPIC and the other inverting? Yes, the two halves are configured independently by which output rail is grounded, so a positive SEPIC rail and a negative inverting rail can come from the same module, as long as each stays inside its own current and voltage limits.
How do I get plus and minus 12 V from a 5 V bus? Set one half as a SEPIC with the positive rail grounded through the divider and the other as inverting. At 12 V out from 5 V in the current folds back well below the 1 A figure, so size the load from the curve for that ratio rather than from the headline number.