Contact Us

LTM8026MPY#PBF

Brand: Analog Devices
Analog Devices LTM8026MPY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8026MPY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8026MPY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8026MPY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8026MPY#PBF: constant current, constant voltage and a -55 C start

The LTM8026MPY#PBF is a 36 V, 5 A constant-voltage constant-current step-down module in an 11.25 mm by 15 mm by 3.42 mm ball grid array with SAC305 balls and MSL 3. It runs from 6 V to 36 V in and 1.2 V to 24 V out, and it regulates output current as well as output voltage, which is what separates it from the rest of the family. The MP grade is -55 C to 125 C at the junction, 15 C wider at the cold end than the E and I codes.

Published values

ParameterValue
Input voltage6 V to 36 V
Output voltage1.2 V to 24 V, RADJ = 11.9 / (VOUT - 1.19), in kohm
Output currentup to 5 A, set by CTL_I, a resistor or a thermistor
Current limit5.6 A typical at CTL_I = 1.5 V, 5.1 A to 6.1 A
Switching frequency100 kHz to 1 MHz, RT sets it
Reference2 V at the VREF pin for divider setting
Junction to ambient18.6 C/W, 5.4 C/W to case bottom
Package11.25 mm x 15 mm x 3.42 mm BGA, SAC305 balls, MSL 3
Temperature range-55 C to 125 C, MP grade
Parallel operationmodules share current, input and output tied

What constant current changes for a buyer

A plain buck regulates voltage and protects itself with a current limit somewhere above the rating. The LTM8026 regulates current as the primary loop up to 5 A, which means the output current is a specification rather than a protection threshold. It can be set by a control voltage on CTL_I, by a single resistor to the 2 V reference, or by a thermistor, and the third option is what makes it usable as a charger rather than only as a supply.

The limit itself sits at 5.6 A typical with CTL_I at 1.5 V, spread 5.1 A to 6.1 A, so the 5 A rating is set by driving CTL_I to 1.34 V. Anyone who ties CTL_I to the maximum and expects 5 A gets 5.6 A on a typical part and 6.1 A on a worst case one, which matters when the load is a supercap bank with no other protection in front of it.

Charging a supercap or a battery

In constant current mode the charge time is arithmetic: 100 F taken from 0 V to 2.5 V at 5 A is 50 seconds, and at a 2.5 A setpoint it is 100 seconds. The module folds into constant voltage at the setpoint and the current falls away, so the tail of the charge is set by the load and not by the module. A thermistor on CTL_T is the usual way to make that current temperature qualified, which is what a battery charger needs and what a fixed resistor cannot do.

The input current is the number that sizes the connector. In the data sheet's own example a module running below 8 A of combined output stays under 750 mA of input current per module, so two modules in parallel for 10 A need a feed sized for the sum and not for one module doubled. That is the difference between a 5 A rail and two 5 A rails that share a connector.

-55 C, and what the grade does not fix

The MP code is -55 C to 125 C at the junction while the E and I codes stop at -40 C. That is a silicon and screening difference, and it does not change the passives around the module. An aluminium electrolytic on the output has its own lower limit, often -40 C, and its ESR at -55 C can be five to ten times the 25 C value, which shows up as output ripple and as a loop that is slower than the bench data taken at room temperature.

Thermally the BGA body is 18.6 C/W junction to ambient with 5.4 C/W to the case bottom. At 36 V to 5 V and 5 A the output is 25 W and a 90 percent figure puts 2.78 W inside the package, which is a 51.7 C rise and about 73 C of ambient at a 125 C junction. A -55 C rating does not add headroom at the hot end, and a sealed enclosure at 85 C ambient is outside that arithmetic whatever the grade says.

Two pages worth reading before a purchase order goes out are the power management cross reference and BOM shortage recovery; the first lists what else fits the socket, the second is the test sequence for a drop in, and medical device components covers the case where the shortage is already on the line.

Two questions buyers ask

Can the current limit be set without a control voltage? Yes. A resistor from CTL_I to the 2 V reference sets the current, and a thermistor in the same place makes it temperature dependent. The control voltage route is used when a housekeeping controller wants to own the setpoint.

Is the MP grade needed for a -40 C product? No. The E and I codes are rated -40 C to 125 C, which covers that. The MP code is for -55 C, and on a -40 C product the extra cost buys nothing unless an approved vendor list names it.