Contact Us

LTM8026MPV#PBF

Brand: Analog Devices
Analog Devices LTM8026MPV#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM8026MPV#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8026MPV#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8026MPV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8026MPV#PBF: the 2.82 mm land grid array and two modules sharing a load

The LTM8026MPV#PBF is the land grid array version of the 36 V, 5 A constant-current module, 11.25 mm by 15 mm by 2.82 mm with Au pads and MSL 3. The BGA body of the same part stands 3.42 mm tall, so 0.6 mm is the only mechanical difference between the two order codes and it is often the difference between fitting under a shield can and not. The MP grade covers -55 C to 125 C and the input range is 6 V to 36 V.

Published values

ParameterValue
Input voltage6 V to 36 V
Output voltage1.2 V to 24 V
Output current5 A, current regulated
Package height2.82 mm LGA against 3.42 mm for the BGA
Pad finishAu, finish code e4
Junction to ambient18.6 C/W, 5.4 C/W to case bottom
Switching frequency100 kHz to 1 MHz
Parallel operationVIN, VOUT and share pins tied
Temperature range-55 C to 125 C, MP grade
Current limit5.6 A typical at CTL_I = 1.5 V

Why the low profile body gets chosen

At 2.82 mm the LGA clears a 3 mm standoff with margin, and the BGA at 3.42 mm does not. On a board where the module sits under a radio shield or on the underside of a card that slides into a 4 mm pitch rack, that is the whole decision, and it is usually made late in a programme by a mechanical engineer rather than by the buyer.

The thermal path is the same for the two bodies at 18.6 C/W junction to ambient, and 5.4 C/W to the case bottom is the number that improves when the board has copper and vias under the module. A 2.82 mm body has less material to spread heat through, so the board stack matters more than it would on a taller part, and a two layer board with no via field under the module will not reach the published figure.

Two modules in parallel for 10 A

Modules in this family share current when VIN, VOUT and the share pins are tied, and the arrangement is common where a 10 A rail is needed and a single module would run at its limit. The published note that each module stays under 750 mA of input current below 8 A of combined output is the sizing rule for the feed, and it is lower than most people expect because the modules are not sharing perfectly at every operating point.

The current limit per module is 5.6 A typical, so a pair is 11.2 A of protection and 10 A of rating. A single shorted output takes the pair into limit together, and each module folds back on its own sense, which means one module can carry more than the other for the duration of the fault. That is acceptable for a rail that recovers, and it is not acceptable for a load that has to see a hard current ceiling, which is where a single module with a setpoint wins.

The cold end of the MP grade

The -55 C rating is what the MP code buys, and it is a junction rating rather than an ambient one, so the board still has to keep the package above -55 C in a cold soak. At -55 C the silicon is fast and the passives are slow: ceramic capacitors lose capacitance with temperature, and the output ripple that was measured at 25 C will be higher at the cold end even though nothing in the module has changed.

A -55 C product normally needs a cold start test at the rail as well as at the module, because the module can start while the load cannot. That test is where a 6 V input floor matters: a cold battery can sit below 6 V, and unlike the 60 V family there is no bias trick that lowers the floor on this part.

Buyers usually arrive at the power management cross reference to find the family alternatives, then use defense grade components to confirm a substitute before it is fitted; component lead time solutions is the routine for a part that has already stopped shipping.

Two questions buyers ask

Does the LGA need a different reflow profile from the BGA? Yes. The LGA has Au pads and the BGA has SAC305 balls, so the paste deposit, the standoff and the profile differ. The land pattern is also different, so the two bodies are not interchangeable on one board.

Can one module be set to 5 A and the other to 3 A in parallel? No. In parallel the two current loops fight each other and the lower setpoint module gives up first. They share properly only when the setpoints match, and the share pins are what keep them matched.