LTM8026EY#PBF
Product Specifications
LTM8026EY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8026EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8026EY#PBF: 3.3 V at 4.75 A with a current limit the vendor tests
The LTM8026EY#PBF is the E grade of the 36 V, 5 A constant-current module in the 11.25 mm by 15 mm by 3.42 mm ball grid array with SAC305 balls and MSL 3. One of the vendor's own application circuits for this part is a 36 V in, 3.3 V out converter with a 4.75 A current limit, which is the arrangement most buyers actually need. The E grade is -40 C to 125 C at the junction.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 6 V to 36 V |
| Output voltage | 3.3 V, RADJ = 11.9 / (3.3 - 1.19) = 5.64 kohm |
| Output current | 5 A rated, 4.75 A in the vendor reference circuit |
| Duty cycle at 3.3 V from 36 V | 9.2 percent |
| Recommended frequency at 3.3 V | 200 kHz, RT 210 k |
| Maximum frequency at 3.3 V | 525 kHz, RT 78.7 k |
| Output ripple | 10 mV RMS at 12 V in and 4.5 A |
| Junction to ambient | 18.6 C/W |
| Package | 11.25 mm x 15 mm x 3.42 mm BGA, MSL 3 |
| Temperature range | -40 C to 125 C, E grade |
Why a 4.75 A limit on a 5 A part
The reference circuit sets the limit just under the rating rather than at it, because the limit has a 5.1 A to 6.1 A spread at the CTL_I setting that corresponds to 5.6 A. A 4.75 A setpoint puts the worst case limit below the 5 A rating, which is what an engineer wants when the load has its own tolerance and the rail feeds a connector.
The duty cycle for that circuit is 9.2 percent at 36 V in, which is 175 ns of on time at 525 kHz, so the frequency ceiling in that row is a real ceiling and not a conservative recommendation. At 12 V in the same output runs at 27.5 percent duty and the module is thermally quieter, which is why the reference circuit's efficiency data is taken from a 12 V bus.
Efficiency and the heat that goes with 16.5 W
3.3 V at 5 A is 16.5 W out, and a 90 percent figure puts 1.83 W in the package, which on 18.6 C/W is a 34 C rise and about 91 C of ambient at a 125 C junction. That is comfortable in still air, and it is the reason this output voltage is the sweet spot in the family: the input current is low enough that the conduction loss stays small.
The same 5 A at 1.2 V out is 6 W, and at 85 percent the loss is 1.06 W, a 19.7 C rise. The thermal problem in this family is never the low voltage rail, it is the 5 V and above rails where the input current and the duty cycle are both high.
Current loop behaviour into a short
In constant current mode a shorted output is a setpoint rather than a fault: the module holds the set current into the short until something else intervenes, which is good for a supercap and bad for a connector. The part also has a thermal path that will eventually fold back, and the time it takes depends on the copper under the package rather than on a timer inside the module.
A short at 5.6 A into 0.1 ohm is 3.1 W in the load and about 2 W in the module, so the module heats at 37 C per second of fault on 18.6 C/W. A load that can short for more than a few seconds needs a fuse or a hot swap controller in front of the rail, and the module's own limit is not a substitute for one.
E grade against I grade in this family
The E and I codes share the -40 C to 125 C window, so the suffix does not change the temperature rating. What changes is the marking, the price and sometimes the lead time, and a production line that has both on the approved vendor list will take whichever is on the shelf.
The MP codes are -55 C and are the only ones that extend the cold end. On a -40 C product, buying MP is paying for a window that is not used, and the money is better spent on the output capacitor's own temperature rating, which is usually the first thing to fail at the cold end.
When an order code in this family cannot be found, the power management cross reference lists what else does the same job, how to verify a drop in replacement covers what to check before a part is dropped into an existing board, and BOM shortage recovery is the route we take on a live shortage.
Two questions buyers ask
Is 4.75 A a rating or a limit? It is the current limit in the vendor's reference circuit. The part is rated 5 A. Setting the limit below the rating keeps the worst case limit under the load the circuit is specified for.
Can the same module charge a battery? Yes. In constant current mode the output is a current source up to the setpoint and folds into constant voltage at the output setting. A thermistor on CTL_T makes the current temperature qualified.