LTM8025MPY#PBF
Product Specifications
LTM8025MPY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM8025MPY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM8025MPY#PBF: a 36 W output at 24 V in, and where the airflow has to come from
The LTM8025MPY#PBF is the MP grade of the 36 V, 3 A step-down module in a 9 mm by 15 mm by 4.92 mm ball grid array with SAC305 balls and MSL 3. It runs from 3.6 V to 36 V in, delivers 0.8 V to 24 V out at up to 3 A, and sets the switching frequency from 200 kHz to 2.4 MHz with one resistor. The MP code is -55 C to 125 C at the junction, the only code in this family that goes below -40 C.
Published values
| Parameter | Value |
|---|---|
| Input voltage | 3.6 V to 36 V |
| Output voltage | 0.8 V to 24 V, ADJ pin regulated to 790 mV |
| Output current | 3 A |
| Switching frequency | 200 kHz to 2.4 MHz, RT sets it |
| Burst mode quiescent current | 50 uA typical at light load |
| Bias requirements | BIAS at least 2.8 V, maximum 25 V, VIN plus BIAS below 56 V |
| Junction to ambient | 24.4 C/W, 11.5 C/W to case bottom |
| Package | 9 mm x 15 mm x 4.92 mm BGA, SAC305 balls, MSL 3 |
| Temperature range | -55 C to 125 C, MP grade |
| Parallel operation | VIN, ADJ, VOUT and SHARE tied |
36 W out of a 9 by 15 mm body
At 24 V in and 12 V out the module is running at a 50 percent duty cycle, which is the easy half. The hard half is the loss: 3 A at 12 V is 36 W out and about 2.71 W inside the package at 93 percent, and the body is quoted at 24.4 C/W junction to ambient. That is a 66 C rise, so a 125 C junction allows about 59 C of ambient, which is an enclosure with airflow and not a sealed box.
The 11.5 C/W junction to case bottom is the route that improves with copper. A via field under the thermal pads and a ground plane extending past the pad boundary can take the effective number toward the bottom figure, and a two layer board with a plane that stops at the pads leaves it at 24.4 C/W whatever the data sheet says. The 42.7 C/W junction to case top is the reason a heat sink on top of a module this size does less than people expect.
Where the 24 V output ceiling comes from
The features list on the front of the document gives an output range of 0.8 V to 24 V and the electrical table pairs RADJ at 16.9 k with 24 V at 36 V in. The operation section describes the output as programmable up to 25 V, which is a sentence that has survived a revision and does not match the table. The table is the governing number for a purchase order.
The ADJ pin is regulated to 790 mV with a window of 775 mV to 805 mV over temperature, so the reference alone is a 3.8 percent spread before the resistor is considered. A 24 V rail built from a 1 percent resistor and a worst case reference sits at 24.6 V, which matters when the load is a 25 V capacitor bank rather than a converter with its own regulation.
Burst mode and the light load the grade does not change
At light load the module drops into burst mode and the input current falls to about 50 uA, which is the number that keeps a standby rail alive on a battery. The MP grade covers -55 C, and the light load behaviour at that temperature is set by the output capacitor's ESR rather than by the module, because the burst frequency rises as the ESR falls.
A -55 C board usually needs a cold start test at the rail, and the module's 3.6 V input floor is the number that decides whether the rail starts from a cold battery. The bias pin needs at least 2.8 V, so a BIAS tied to a 3.3 V output is fine and a BIAS tied to a 0.8 V output is not.
Ordering the MP code and the paste-in-hole question
The MPY is the ball grid array, and the MPV is the land grid array of the same die. The two are not interchangeable: the land pattern, the standoff and the reflow profile differ, and the LGA stands 4.32 mm against 4.92 mm for the BGA.
The BGA at 4.92 mm is the taller of the two, which matters on the underside of a board with a 5 mm standoff. Where height is not a constraint the ball grid array is the more common body in production because the solder joints are inspectable by X-ray in a single pass rather than by edge inspection.
Two pages worth reading before a purchase order goes out are the power management cross reference and defense grade components; the first lists what else fits the socket, the second is the test sequence for a drop in, and component lead time solutions covers the case where the shortage is already on the line.
Two questions buyers ask
Is the maximum output 24 V or 25 V? 24 V. The electrical table pairs 16.9 k on ADJ with 24 V at 36 V in. A sentence in the operation section mentions 25 V, and the table governs the rating.
Does the -55 C grade apply to the whole module? It is a junction rating for the module. The capacitors around it have their own limits, and an aluminium electrolytic rated -40 C is the part that fails first on a cold start.