Product Specifications

LTM8020IV#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM8020IV#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM8020IV#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM8020IV#PBF: 200 mA from a 36 V rail, and the 85 degree C window the I suffix does not widen

The LTM8020IV#PBF is a complete 200 mA step-down regulator in a 6.25 mm by 6.25 mm by 2.32 mm land grid array, with the controller, the switches, the inductor and the support parts inside the package. It takes 4 V to 36 V in and delivers 1.25 V to 5 V out at 200 mA, and it meets the radiated emissions requirement of EN55022 Class B without external filtering. The suffix question that comes up most often on this part is what the I buys over the E, and on this data sheet the answer is not a wider temperature window.

Published values

ParameterValue
Input voltage4 V to 36 V, 40 V absolute maximum
Output voltage1.25 V to 5 V, set by one resistor
Output current200 mA continuous
Radiated emissionsEN55022 Class B compliant
Controlcurrent mode, Burst Mode operation at light load
Thermal resistance23.1 degree C per W junction to ambient
Maximum junction temperature125 degree C
Package21-lead LGA, 6.25 mm x 6.25 mm x 2.32 mm
Weight0.25 g
E and I grade rangeminus 40 degree C to 85 degree C
MP grade rangeminus 55 degree C to 125 degree C
Output set resistor165 k for 5 V, 301 k for 3.3 V

One watt out at 5 V and the loss that follows it

Five volts at 200 mA is 1 W of output. If the conversion runs at 80 percent, the input power is 1.25 W and the loss is 0.25 W, which at 23.1 degree C per W is a 5.8 degree C rise over ambient. The part is thermally easy at its own current rating: the package is not the limit, the ambient is. At 85 degree C ambient the junction sits near 91 degree C, inside the 125 degree C maximum, and that is exactly why the E and I grades stop at 85 degree C ambient rather than at 125.

The same arithmetic from a 36 V rail changes nothing about the loss but changes the input current: 1.25 W at 36 V is 34.7 mA, so the 200 mA output is a 35 mA load on the high rail and the input capacitor sees a pulsed current of that average with a much higher peak. That is why the data sheet asks for a 2.2 uF ceramic at the input and a 4.7 uF or larger at the output, and why a long supply lead with no local capacitor turns a quiet regulator into a radiator.

Duty cycle, dropout and the 4 V floor

Thirty six volts in and 1.25 V out is a 3.5 percent duty cycle, and 36 V in to 5 V out is 13.9 percent. The low end of the output range is where the minimum on time and the current limit interact, so the 4 V input floor in the specification is not the same as the 6.5 V the front page typical application prints as its running range for a 5 V output: the 4 V figure is the point at which the regulator still starts, and the application note asks for 6.5 V to hold 5 V out with margin.

At the other end, the internal switch stands off the full 36 V while it carries the inductor current, and the package is 6.25 mm square. The 40 V absolute maximum is only 4 V above the top of the operating range, so a 36 V rail with a transient has to be clamped or the part has to be fed through a series element. This is the usual failure mode on 24 V industrial rails with inductive kick.

The output resistor sets the voltage downward, not upward

The output is set by a single resistor from the ADJ pin, and the values in the data sheet run the other way from what most people expect: 165 k gives 5 V and 301 k gives 3.3 V, because the resistor is in the feedback divider's upper leg and a larger value lowers the output. The 1.228 V to 1.265 V reference at the ADJ pin is the floor of the range, so 1.25 V out is the reference itself and cannot be taken lower without an external offset.

For a build that needs two rails, the same resistor change is a rework item rather than a new part number, which matters at the end of a project when a rail has to move by 100 mV. What does not move is the 200 mA rating: it is a continuous dc figure, and a load that draws 400 mA for a few milliseconds is outside the part even though the average is inside it.

When an order code in this family cannot be found, the power management cross reference lists what else does the same job, component lead time solutions covers what to check before a part is dropped into an existing board, and vendor consolidation is the route we take on a live shortage.

Two questions buyers ask

Does the I grade buy a wider temperature range than the E grade? Not on this data sheet. The ordering table gives LTM8020EV#PBF and LTM8020IV#PBF the same minus 40 degree C to 85 degree C range, and the only wider option in the family is the MP grade at minus 55 degree C to 125 degree C. So the suffix choice between E and I is about the guarantee and the test flow, not about the ambient the part survives, and a build specified to 105 degree C has to move to the MP part.

Is the 200 mA rating a peak or a continuous figure? It is the continuous output dc current. The package has no headroom for a sustained overload, and the internal current limit protects the part rather than the load, so a capacitive load that draws a large inrush has to be handled with a soft start or a series element. On a 200 mA rail the typical mistake is sizing the inductor and capacitors for 500 mA because a transient was observed once.