Contact Us

LTM4700IY#PBF

Brand: Analog Devices
Analog Devices LTM4700IY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM4700IY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM4700IY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM4700IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM4700IY#PBF: 100 A at 1 V, 11 W of loss, and a 15 mm by 22 mm body to get it out of

The LTM4700IY#PBF is a dual 50 A or single 100 A step-down module with a PMBus interface for control, compensation and telemetry, in a 15 mm by 22 mm by 7.87 mm ball grid array. It runs from 4.5 V to 16 V in and 0.5 V to 1.8 V out, delivers about 90 percent from 12 V to 1 V at 100 A, holds plus or minus 0.5 percent of dc output error over temperature and reads current back to plus or minus 3 percent. At 100 A the arithmetic that matters is not the current rating, it is the 11 W that has to leave a 330 square millimetre package.

Published values

ParameterValue
Input voltage4.5 V to 16 V
Output voltage0.5 V to 1.8 V
Output currentdual 50 A or single 100 A
Full load efficiencyabout 90 percent, 12 V in to 1 V out at 100 A
DC output errorplus or minus 0.5 percent maximum over temperature
Current readback accuracyplus or minus 3 percent, 25 degree C to 125 degree C
Digital interface400 kHz PMBus compliant I2C, 16-bit ADC, polling to 125 Hz
Non volatile memoryinternal EEPROM with ECC and a fault log
Thermal resistance8.5 degree C per W
PackageBGA, 15 mm x 22 mm x 7.87 mm
Weight9.5 g
Moisture sensitivityMSL 4

Eleven watts of loss on a 330 square millimetre package

One hundred amps at 1 V is 100 W of output. At 90 percent the input power is 111 W, so 11.1 W is dissipated and, at 12 V, the input current is 9.26 A. At 8.5 degree C per W the rise is 94 degree C, which means a 45 degree C ambient already puts the junction at 139 degree C. The package is not the answer to that; airflow over the top, copper through the ball array and a heat spreader are, and the data sheet's thermal numbers are quoted for conditions that include airflow.

The same module at dual 25 A per channel dissipates 2.8 W at the same efficiency and has a 24 degree C rise, so the thermal problem is a function of how close the build is to the 50 A per channel limit. Most builds that choose this part for its telemetry run it well below 100 A, and the full rating is used only with a forced air path.

The PMBus interface is a measurement instrument as much as a control port

A 16-bit ADC with 400 kHz PMBus and polling to 125 Hz gives input and output voltage, current, power, temperature, uptime and peak values, with plus or minus 0.5 percent dc output error and plus or minus 3 percent current readback from 25 degree C to 125 degree C. Three percent of a 50 A channel is 1.5 A, so the telemetry is a trending and fault tool rather than a calibration reference: a build that bills energy from this readback carries a 3 percent error in the number.

The EEPROM with ECC and the fault log are what make the part useful in a system that has to record why it shut down. The log survives a power cycle, and the peak values are latched, so a supply that trips once a week on an overcurrent can be diagnosed from the log rather than from a scope on the bench.

Single 100 A and dual 50 A are the same silicon in two configurations

The module is two 50 A channels that can be paralleled into one 100 A output with current sharing, and the switching phases can be set by pin strapping at start-up so the two channels interleave. Interleaving halves the input ripple at the switching frequency and doubles it at twice the frequency, which changes the input capacitor requirement rather than the dc rating: a single 100 A rail does not need twice the input capacitance of a 50 A one if the phases are set correctly.

Output voltage, switching frequency and phase angle can all be set by pin strapping resistors without writing the EEPROM, which is what makes the part usable in a build that has no firmware path to it. The PMBus connection is then optional and the part behaves as an analog regulator with a digital monitor, which is a legitimate and common configuration.

Buyers usually arrive at the power management cross reference to find the family alternatives, then use the ADC and DAC cross reference to confirm a substitute before it is fitted; one stop BOM sourcing is the routine for a part that has already stopped shipping.

Two questions buyers ask

Is 100 A available at any output voltage in the range? The output range is 0.5 V to 1.8 V and the 100 A figure is the current rating, with the thermal limit arriving first at the higher output voltages because the loss is roughly constant while the output power rises. At 0.5 V and 100 A the output is 50 W and the loss is about 5.5 W, which is a much easier thermal case than 1.8 V at the same current.

Does the module need firmware to start? No. Output voltage, switching frequency and channel phase can be set by pin strapping resistors at start-up, and the module regulates without any bus traffic. PMBus is needed only to change settings at run time, to margin rails or to read the telemetry and the fault log.

The 4.5 V input floor against a 5 V rail at minus five percent

The input range of this module starts at 4.5 V, and a 5 V rail at minus five percent is 4.75 V, which is 250 mV of margin before a connector, a fuse and a trace are counted. A 5 V backplane that also feeds a disk or a fan through the same connector can drop below 4.5 V during a spin up, and the module then goes into undervoltage lockout and the rail collapses rather than sagging.

From 5 V in, 100 A at 1 V needs 111 W of input, which is 22.2 A of input current, and that current through 20 milliohms of connector and trace is 0.44 V, which alone eats the margin. From 12 V the same 111 W is 9.26 A and the same 20 milliohms is 0.19 V. The input voltage a rail this size runs from is therefore a distribution decision as much as a regulator one, and the 4.5 V floor is the number the distribution has to respect under all load conditions, not at nominal.