LTM4650MPY#PBF
Product Specifications
LTM4650MPY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM4650MPY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM4650MPY#PBF: The -55 C to 125 C Grade of the 50 A Module
The LTM4650MPY#PBF is the MP grade of the LTM4650: dual 25 A or single 50 A, 4.5 V to 15 V in, 0.6 V to 1.8 V out, 35 A typical current limit, differential remote sense, multiphase to 300 A, in the 16 mm by 16 mm by 5.01 mm BGA with SAC305 balls. What the MP suffix buys is the guarantee: the part is tested and guaranteed over -55 C to 125 C internal, where the E grade is guaranteed from 0 C and the I grade from -40 C. That is a 15 C extension at the cold end over the I part, and it is the only reason to pay the MP price on a rail that would otherwise be fine with an I.
Published values
| Parameter | Value |
|---|---|
| Input range | 4.5 V to 15 V |
| Output range | 0.6 V to 1.8 V per channel |
| Output current | 25 A per channel, 50 A single output |
| Total DC error | plus or minus 1.5 percent, 1.182 V to 1.218 V at 1.2 V |
| Current limit | 35 A typical per channel |
| Bias current | 4.5 mA burst, 25 mA pulse skip, 240 mA continuous, 35 uA shutdown |
| Switching frequency | 500 kHz nominal, 400 kHz to 780 kHz operating |
| Minimum on time | 90 ns |
| Load step | 30 mV peak deviation, 20 us settle |
| Thermal | 7 C/W junction to ambient, 1.5 C/W junction to case bottom |
| Package | 16 mm x 16 mm x 5.01 mm BGA, 144 balls, SAC305, 3.2 g, MSL 3 |
| Temperature | MP grade tested and guaranteed -55 C to 125 C internal |
| Storage | -55 C to 125 C, 245 C peak package body |
What changes between -40 C and -55 C
The module itself is the same silicon and the same package. The difference is the test and the guarantee, and it shows up in three places on a customer's qualification plan: the cold start test at -55 C, the thermal cycling range, and the storage specification, which for the MP part is -55 C to 125 C against -65 C to 150 C on the quad module family. A procurement engineer who needs the MP grade usually has it written into a specification that came from the end customer, not from an engineering assessment.
The cold end is where the passive parts around the module matter more than the grade. A ceramic output bank loses a large share of its capacitance at -55 C and its ESR rises, so the 30 mV load step deviation published at 25 C is not the number that applies. The module will still regulate, the deviation will be larger, and the capacitor data has to be read at the cold end before the rail is signed off.
Fifty amps in one package, at the cold end
A single 50 A output at 1.2 V is 60 W. At 90 percent that is 6.67 W inside the package, which at 7 C/W is a 47 C rise. From a -55 C start the junction has 180 C of headroom, from a 70 C ambient it has 55 C, and those two cases are the same hardware with different derating curves. The MP grade does not add thermal capacity, it only widens the temperature window in which the published numbers hold.
At the hot end, 115 mA of bias at 12 V is 1.38 W of the total, and the current limit of 35 A is the number that sets the inductor, not the 25 A rating. A fault on a 50 A rail will pull 70 A through the two channels before foldback, and the module is specified to survive that, but the copper around it sees it too.
How the grade shows up in the order code
LTM4650MPY#PBF: LTM4650 family, MP grade, Y is the BGA, #PBF is RoHS with SAC305 balls. The same grade also ships as LTM4650MPY without the #PBF suffix, which is the SnPb finish for customers who are still on a tin lead process. The two are not interchangeable under RoHS rules, and the finish code on the shipping label is what a compliance audit will ask for.
The MP code is the one that tends to be on allocation, because it is built in smaller volume than the E and I parts. A rail that only needs -40 C should be quoted with the I code and the MP code as a second position, priced and dated separately, rather than assumed to be interchangeable at the point of purchase.
Where a customer needs a second position on this part, defense grade components is the starting point, the obsolete part cross reference hub sets out the checks a substitution has to pass, and vendor consolidation is the short lead time route we quote against.
Two questions buyers ask
Is the MP part a different die from the I part? The data sheet presents one device, the LTM4650Y, with the grade indicated by a label on the shipping container and the guarantee table setting out what each grade is tested to. The safe reading is that the MP code is the same module with a wider guarantee, not a different converter, and any quotation should confirm the grade in writing rather than infer it from the part number.
Does the MP grade change the pin out? No. All the codes in this family share the 144 ball, 16 mm by 16 mm BGA, and the two finish options are the only difference on the package itself. A board qualified with an I code will accept the MP code without a change.