Contact Us

LTM4649IY#PBF

Brand: Analog Devices
Analog Devices LTM4649IY#PBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTM4649IY#PBF — Analog & Mixed-Signal ICs | Superb Automation

LTM4649IY#PBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTM4649IY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

Request Quote — In Stock, 100% New & Original, Full Warranty

LTM4649IY#PBF: The I Grade 10 A Module and What the Sense Amplifier Buys

The LTM4649IY#PBF is the I grade of the 10 A single output module: 4.5 V to 16 V in, 0.6 V to 3.3 V out, plus or minus 1.5 percent total DC error, differential remote sense, multiphase operation with current sharing, an on board temperature monitor and selectable burst or pulse skip mode. The package is a 9 mm by 15 mm by 4.92 mm BGA with SAC305 balls, 1.7 g, MSL 3. The I grade is guaranteed over -40 C to 125 C internal, where the E code in the same family is guaranteed from 0 C.

Published values

ParameterValue
Input range4.5 V to 16 V
Output range0.6 V to 3.3 V
Output current10 A continuous
Total DC errorplus or minus 1.5 percent, 1.477 V to 1.523 V at 1.5 V
Reference0.593 V to 0.607 V over temperature
Current limit12 A typical
Bias current75 mA continuous, 15 mA pulse skip, 5 mA burst, 70 uA shutdown
Minimum on time90 ns
Load step60 mV deviation, 20 us settle
Thermal14 C/W junction to ambient, 5 C/W junction to case bottom
Package9 mm x 15 mm x 4.92 mm BGA, 68 balls, 1.7 g, MSL 3
TemperatureI grade guaranteed -40 C to 125 C internal

What 60 mV of load step deviation means

The published peak deviation is 60 mV for a 0 to 50 to 0 percent load step on a 1.5 V rail with 100 uF of ceramic and a 100 uF POSCAP. That is 4 percent of the rail, and it settles in 20 us. For a rail that feeds an FPGA transceiver bank the settling time matters as much as the peak: a 20 us recovery is within what most loads tolerate, and it comes from the current mode loop being fast rather than from a large capacitor bank.

The 1.5 percent DC window is 23 mV at 1.5 V, and the load step takes the output 60 mV away from wherever it was. Those two numbers are different measurements of different things, and a customer who compares them will conclude the rail is out of specification. It is not: one is a transient, the other is a DC error band.

Remote sense, and the copper it removes from the budget

The differential sense amplifier has a gain of one, an input resistance of 80 k on each input, a common mode range up to 3.6 V and an offset of 4 mV maximum. Connected at the load, it removes the drop in the output trace from the regulation. On a 10 A rail with 3 milliohms of trace and connector that drop is 30 mV, which is more than the entire 23 mV DC window. Without remote sense the rail is specified at the pins and the load sees whatever the copper leaves.

The sense traces have to be Kelvin connected and they have to be routed away from the switch node, because the amplifier has a 3 MHz gain bandwidth product and a 60 dB common mode rejection at low frequency, which falls with frequency. A sense pair that runs next to the inductor couples switching noise straight into the feedback, and the symptom is jitter in the output rather than a DC error.

Cold start and the 90 ns limit

The I grade covers -40 C, and at that temperature the module's reference is inside its window. What is not inside any window is the ceramic output bank, which loses capacitance and gains ESR, so the 60 mV deviation grows. The 5 ms soft start with 0.01 uF on TRACK/SS sets the ramp at both ends of the temperature range, and the tracking pull up current of 1.2 uA is what defines that ramp.

The minimum on time is 90 ns, so a 0.6 V rail from 16 V needs a frequency below about 417 kHz. From 12 V the same rail is 5 percent duty and 100 ns at 500 kHz. Any quotation for a 0.6 V rail from a 15 V or 16 V bus should carry the frequency with it, because the two numbers are not independent.

Sourcing this code

The order table lists EY and IY in SAC305 plus IY in SnPb, and there is no MP grade for this part. A requirement below -40 C therefore needs a different module in the family rather than a different suffix, and the 12 A current limit is the fault current the output trace has to survive, not the 10 A rating.

Because the package is 68 balls on a 9 by 15 mm outline, it drops onto the same area as a quad module but with a single output. That makes it the natural second position for a 10 A rail that was originally built from a controller plus FETs, where the board area was the constraint and the loop tuning was the schedule risk.

For a board that has to keep running while a reel runs out, the obsolete part cross reference hub is where the family alternatives sit, vendor consolidation is the check list before a substitute goes in, and medical device components is how a gap is covered without a new line item.

Two questions buyers ask

Is there a grade colder than the I part? Not in this family. The order table lists EY and IY only, so -55 C needs a different series. This is one of the few modules where the MP suffix does not exist, and a specification that calls for it cannot be met by relabelling.

Can the temperature monitor drive a comparator directly? It is a diode connected PNP with a -2.2 mV per C coefficient at 100 uA, so it needs a current source and a comparator with a reference. It measures the module rather than the air, which is the useful part on a sealed card.