LTM4649EY#PBF
Product Specifications
LTM4649EY#PBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTM4649EY#PBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
LTM4649EY#PBF: 10 A From 4.5 V to 16 V With No Derating to 85 C
The LTM4649EY#PBF is a single output 10 A step down module: 4.5 V to 16 V in, 0.6 V to 3.3 V out, plus or minus 1.5 percent total DC voltage error, remote sense, multiphase operation with current sharing, a temperature monitor output, and selectable pulse skipping or burst mode for light load. The headline in the feature list is the one to hold on to: no heatsink and no current derating up to an 85 C ambient. The package is a 9 mm by 15 mm by 4.92 mm BGA at 1.7 g, MSL 3.
Published values
| Parameter | Value |
|---|---|
| Input range | 4.5 V to 16 V |
| Output range | 0.6 V to 3.3 V |
| Output current | 10 A continuous |
| Total DC error | plus or minus 1.5 percent, 1.477 V to 1.523 V at 1.5 V |
| Current limit | 12 A typical |
| Bias current | 5 mA burst, 15 mA pulse skip, 75 mA continuous, 70 uA shutdown |
| Minimum on time | 90 ns |
| Load step | 60 mV deviation, 20 us settle at 1.5 V |
| Thermal | 14 C/W junction to ambient, 5 C/W junction to case bottom, 20 C/W to case top |
| Package | 9 mm x 15 mm x 4.92 mm BGA, 68 balls, 1.7 g, MSL 3 |
| Temperature | E grade guaranteed 0 C to 125 C internal |
| Derating | no heatsink and no current derating to an 85 C ambient |
The derating claim, in watts
Ten amps at 1.5 V is 15 W. The published supply current at 12 V in is 1.5 A, so the input is 18 W and the loss is 3 W, about 83 percent efficiency. With 14 C/W junction to ambient, 3 W is a 42 C rise, and at an 85 C ambient that puts the junction at 127 C, which is just past the 125 C limit. The claim of no derating to 85 C therefore rests on the test board's thermal path rather than on still air at 14 C/W, and the derating curves in the datasheet are the place to confirm what a particular board does.
The 5 C/W junction to case bottom is the figure that explains the claim. Three watts through 5 C/W is 15 C over the copper, so a board with a solid ground plane under the lands holds the junction near 100 C at an 85 C ambient. A board without that copper will not reproduce the headline, and the difference is in the stack up rather than in the module.
The 90 ns minimum on time and a 0.6 V rail
A 0.6 V output from a 16 V input is 3.75 percent duty. At 500 kHz the period is 2 us, so the on time would be 75 ns, below the 90 ns minimum, and the frequency has to fall to about 417 kHz. From 12 V the same rail is 5 percent duty and 100 ns at 500 kHz, which fits. This is the same arithmetic that governs every module in this class, and it is the reason a 0.6 V rail should never be quoted at the top of the input range without checking the frequency.
At the other end, a 3.3 V rail from a 4.5 V input is 73 percent duty, which leaves 27 percent of the period for the off time. At 500 kHz that is 540 ns against a minimum off time of the same order, so the top of the output range and the bottom of the input range is the pair to check for both limits at once.
Three amps of loss and where it goes
Fifteen watts of output from an 18 W input leaves 3 W to dissipate, and the split between the top and bottom path is set by the board. Through the case bottom at 5 C/W that is a 15 C rise, through the top at 20 C/W it is 60 C. The 4.92 mm height exists to give the inductor room and to give the board a path, and a customer who mounts this vertically with no copper underneath is relying on the 14 C/W ambient figure, which is a test board number.
Bias current at 12 V is 75 mA continuous, 0.9 W, and that is part of the 3 W. Burst mode drops it to 5 mA and 60 mW, which on a rail that idles at low current changes the standby loss by a factor of fifteen. Shutdown is 70 uA, 0.84 mW.
Remote sense and the 12 A limit
The remote sense amplifier is a differential input with a common mode range up to 3.6 V and a gain of one, so the feedback can be taken at the load rather than at the output pins. On a 10 A rail that is worth 20 to 30 mV of copper drop at 1.2 V, which is a third of the 1.5 percent budget. The output overvoltage lockout at 0.66 V on a 0.6 V reference is the other end of the same budget.
The 12 A typical current limit against the 10 A rating is 20 percent of headroom. That is the current the inductor inside the package sees during a fault, and it is also the number to use when sizing the output trace and the connector, not the 10 A rating.
When an order code in this family cannot be found, the power management cross reference lists what else does the same job, defense grade components covers what to check before a part is dropped into an existing board, and how to reduce component cost is the route we take on a live shortage.
Two questions buyers ask
Can this be paralleled for 20 A? The family supports multiphase operation with current sharing and a PHMODE pin, so two modules can run in parallel with the phases staggered. The sharing is set by the modules; the board has to tie the outputs at the load and provide a common clock through CLKIN.
What are the available order codes? The order table lists LTM4649EY#PBF and LTM4649IY#PBF, both SAC305, plus LTM4649IY in SnPb. There is no MP grade listed for this part, so a requirement below -40 C needs a different module rather than a different suffix.