Contact Us

LTC6101HVCCS5#TRPBF

Brand: Analog Devices
Analog Devices LTC6101HVCCS5#TRPBF is a analog & mixed-signal component designed for Precision Instrumentation and related applications. In stock at Superb Automation — request a quote for competitive pricing and fast delivery.
quote now

Product Specifications

LTC6101HVCCS5#TRPBF — Analog & Mixed-Signal ICs | Superb Automation

LTC6101HVCCS5#TRPBF

Analog Devices — Analog & Mixed-Signal ICs

Product Overview

The LTC6101HVCCS5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.

Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.

Key Features

  • High-resolution data conversion with excellent SNR and THD
  • Wide dynamic range and high linearity across operating conditions
  • Integrated voltage reference with low temperature drift
  • Flexible digital interface — SPI, I2C, or parallel options
  • Industrial/automotive temperature range with guaranteed specs
  • Low power consumption with power-down modes

Key Specifications

Resolutionbits
Channels—
Sample RatekSPS
Interface—
Supply VoltageV
Operating Temp°C
Package—
INLLSB
SNRdB
THDdB

Applications

Precision Instrumentation Industrial Process Control Medical Imaging & Diagnostics Automotive Sensor Interfaces Communications Infrastructure Test & Measurement

LTC6101HVCCS5#TRPBF: 100 V current sense, commercial temperature letter

What this order code is

LTC6101HVCCS5#TRPBF is the same high voltage current sense amplifier in the 5-lead SOT-23 and tape and reel, with the temperature letter that covers the commercial range rather than the industrial one. The electrical behaviour is the family behaviour: 5 V to 100 V supply, 105 V absolute maximum, 500 mV maximum sense voltage, 300 uV maximum offset, gain set by two resistors, 1 us response.

The distinction between this code and the industrial letter is the guaranteed window, and it matters when the same board is sold into two markets: one build can carry the wider letter and the other the narrower one, on the same copper and the same shunt, with the measurement accuracy unchanged inside the commercial range.

Parameters as published

ItemValue
Supply range, HV part5 V to 100 V, 105 V absolute maximum
Maximum sense voltage500 mV
Input offset voltage300 uV maximum
Input bias current170 nA maximum
Gainset by two external resistors
Response time1 us, 0 to 2.5 V output step
Power supply rejection118 dB minimum
Output current1 mA maximum
Supply current375 uA typical at 60 V
Specified range-40 C to 125 C, family figure
Operating range-55 C to 125 C, family figure
Body5-lead SOT-23, 1 mm profile
Packingtape and reel

Numbers that decide the application

Supply current is the number that decides whether this part can sit on a standby rail. At 250 uA the annual charge is 2.19 Ah, and at the 375 uA typical figure quoted at 60 V it is 3.29 Ah, so a monitoring amplifier left on permanently is a real term in a battery budget and not a rounding error. On a mains powered 48 V bus it is 12 mW at 48 V and irrelevant; on a battery string it is the reason the part is switched or the reason a lower current monitor is chosen.

The 100 V ceiling with a 105 V absolute maximum is 5 percent of headroom above the operating limit. On a 96 V battery string the operating point is inside the part with 4 V to spare, and a transient above 105 V is outside it, so a string that can see a charger overshoot needs a clamp upstream rather than a hope that the absolute maximum is a working range.

Offset against signal is the accuracy story again. At a 500 mV full scale the 300 uV offset is 0.06 percent, at 50 mV it is 0.6 percent, at 5 mV it is 6 percent. This part is therefore at its best with a shunt that develops tens of millivolts, which at 20 A means 1 to 2 milliohms and 0.4 to 0.8 W of shunt loss. Below that the offset dominates and the measurement becomes a threshold detector rather than a meter.

The 1 us response time is fast enough for overcurrent detection in a switching supply and slow enough that a 100 kHz ripple on the bus is averaged rather than followed, which is usually what a current limit wants.

Where it fits and where it does not

It fits a 48 V telecom bus, a 96 V battery string, a hot swap current limit, a motor drive supply, and any board where a commercial temperature window is enough and the cost of the wider letter is not justified. It does not fit a bus above 105 V, a sense voltage above 500 mV, or a battery powered monitor where 250 uA continuously is a large share of the budget.

Supply and second source questions

The letters after HV are a gain grade and a temperature grade, and because the family figures are maxima that apply across those letters, two codes look identical in a catalogue and differ in the ordering table. That is the field to compare, not the headline offset. Monitoring and converter parts are grouped on the converter and monitoring cross reference page.

Sourcing notes and next step

We quote the HV code and report the grade and temperature letters actually on the reel, because a line that needs the wider window cannot take this one. Send the line items through the BOM shortage recovery page and we will answer with availability. The analog range is on the analog and mixed signal IC page.

Request Quote — In Stock, 100% New & Original, Full Warranty