LTC6101BCS5#TRPBF
Product Specifications
LTC6101BCS5#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC6101BCS5#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC6101BCS5 as a value grade high side monitor
The LTC6101BCS5 is the B grade letter in the commercial temperature letter on the plain 4 V to 60 V member of the family, five lead SOT-23, 70 V absolute maximum. It is the code that makes sense when the channel is a 12 V or 24 V rail, the shunt is a 1 percent part, and the reading only has to support a status decision rather than a metering claim.
Why the value grade is enough on a wide sense drop
The family publishes a 300 uV maximum offset line and puts the per grade limits in the ordering information, so the way to decide is to compare the published limit against the sense drop the shunt produces. At 100 mV of sense drop, 300 uV is 0.3 percent, and a grade at twice that limit is 0.6 percent, which a 1 percent shunt cannot resolve. At 10 mV of sense drop the same two limits are 3 percent and 6 percent, and a 1 percent shunt is no longer the dominant term. The grade only pays on a small sense drop.
The arithmetic of a 24 V, 5 A channel
| Item | Value | Note |
|---|---|---|
| Shunt | 10 mohm | 50 mV at 5 A, 0.25 W |
| Offset share | 0.6 percent | 300 uV against 50 mV |
| Common mode error at 24 V | 30 uV | from the 118 dB minimum rejection |
| Bias into 1 kohm | 170 uV | from the 170 nA maximum |
| Supply current | 250 uA at 12 V | 2.19 Ah over a year |
| Output limit | 1 mA | gain of 20 into 1 kohm is exactly at it |
Adding the three error terms in quadrature gives about 0.7 percent on the 50 mV drop, against 1 percent for the shunt itself. That is the argument for this grade on this channel: the amplifier is not the limit, so a tighter grade would buy nothing that shows up in the reading.
What the C letter means for the enclosure
The C letter is the commercial temperature code and the family page publishes -40 to 125 C as the specified range with the per letter window in the ordering information. A product that sits in a cabinet at 40 C internal ambient is inside the C letter's intent. A product that runs a 48 V drive at 85 C internal ambient is not, and the I letter costs less than a field return. The thermal question is not the amplifier's own dissipation, which is 12.5 mW at 250 uA and 12 V, but the shunt sitting on the same copper at 0.25 W.
Where this code fits
24 V industrial supplies, 12 V battery monitoring, fan and pump controllers, and status level current sensing where the trip point matters more than the reading. The 1 us response for a 0 V to 2.5 V output step lets the same signal drive a comparator, so a hardware limit does not need a separate sense channel.
Mounting the 1 mm body next to the shunt
The five lead SOT-23 is 1 mm tall and that matters because the heat source on this channel is not the amplifier. A 10 mohm shunt at 5 A is 0.25 W sitting a few millimetres away, and the copper that carries the 5 A to it is also the copper that has to take that heat away. Two things follow. First, the sense traces to the amplifier must be taken from inside the shunt pads rather than from the power path, or the trace resistance adds a term that varies with temperature. Second, the amplifier's own 12.5 mW at 250 uA and 12 V is irrelevant beside the shunt, so the thermal question belongs to the resistor and to the pour under it, not to the part in the SOT-23. Where the shunt is a 1 percent part, place it so that its temperature coefficient, typically 50 to 100 ppm per degree, is not multiplied by a 60 degree rise that the board build could have avoided.
Sourcing notes and next step
Two codes that differ only in a grade letter are the same body, pin map and price band in most quotations, so a bill that lists the family name alone will drift between grades as stock moves. Pin the full code. Where the B grade is short, the A grade is a drop in that tightens the offset and costs more, which is the cheapest substitution in this family because nothing else moves. Our component cost page covers the grade against price trade, the ADI second source page lists the codes we can quote, and the analog and mixed signal category holds the rest of the family.
LTC6101BCS5#TRPBF: a 10 mOhm shunt, a gain pair, and the 0.6 percent an offset puts back into a 5 A channel
A current monitor is a chain of four decisions: the shunt, the gain pair, the filter and the supply rail the output has to reach. Each one costs accuracy or speed, and the cheapest mistake is to size the gain for the full scale of the amplifier instead of the full scale of the converter that reads it. This block works a 24 V, 5 A channel end to end and then looks at what happens when the load is shorted, because that is the condition the monitor exists for.
The gain pair sets the full scale, so start from the converter
A 10 mOhm shunt at 5 A drops 50 mV and dissipates 0.25 W. With a gain of 50 the output reaches 2.5 V, with 60 it reaches 3.0 V, and with 100 it reaches 5.0 V. On a 3.3 V converter the 100 setting clips at 3.3 A and hides the top of the range, which is exactly where a fault appears, so the 60 setting is the one to build: 3.0 V at 5 A leaves 300 mV of headroom and still uses 91 percent of the input span. The pair has to be a ratio, not two resistors that happen to be the right value, because a 0.1 percent part on each side is worth up to 0.2 percent of gain error and the ratio is the only thing the amplifier sees.
The offset is the error that does not scale with current
A 300 uV input offset across 10 mOhm reads as 30 mA, which is 0.6 percent of a 5 A full scale and, more importantly, is a fixed current error that cannot be calibrated out without a second measurement point. The shunt tolerance usually dominates: a 1 percent shunt is a 1 percent gain error at every current, so the order of work is to buy a 0.5 percent shunt before paying for a better grade of amplifier. The third term is the amplifier's own gain error, which a trimmed pair takes under 1 percent, so a channel built from a 0.5 percent shunt, a 0.1 percent pair and a 300 uV offset lands near 1.8 percent worst case and near 0.7 percent typical.
Filtering, settling and what the output does into a shorted load
A 1 k resistor and a 100 nF capacitor at the output give a 100 us time constant and a 1.6 kHz corner, which is right for a monitoring channel and wrong for protection: a 5 A short is only visible in the converter half a millisecond later. A 10 nF capacitor moves the corner to 15.9 kHz and the time constant to 10 us, which is the usual compromise when the same signal feeds both a protection comparator and an ADC. The 1 k also loads the output, and at 3 V that is 3 mA of standing current that the sense amplifier has to source. On a short the shunt carries the full 24 V through the fault path and the 0.25 W part becomes a 58 W part for as long as the fault lasts, so the monitor is a witness rather than a protector: the pin that has to be protected is the inverting input, which must not be pulled below its negative limit by the inductance of the fault loop.
| Gain | Output at 5 A | Full scale on a 3.3 V converter | Where it fits |
|---|---|---|---|
| 50 | 2.50 V | 5 A with 800 mV spare | Wide margin, poor resolution |
| 60 | 3.00 V | 5 A with 300 mV spare | Full 5 A range on 3.3 V |
| 100 | 5.00 V | 3.3 A before clipping | 5 V converter only |
The grade against price trade is on component cost reduction, the codes we can quote against an existing bill are on pin to pin cross reference, and the rest of the monitor family is indexed on amplifier cross reference.
Request Quote — In Stock, 100% New & Original, Full Warranty