LTC5582IDD#TRPBF
Product Specifications
LTC5582IDD#TRPBF
Analog Devices — Analog & Mixed-Signal ICs
Product Overview
The LTC5582IDD#TRPBF from Analog Devices is a high-performance analog / mixed-signal IC providing precision signal acquisition, conversion, and conditioning. Analog Devices (ADI) is a world leader in high-performance analog, mixed-signal, and DSP ICs for instrumentation, healthcare, automotive, and communications.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-resolution data conversion with excellent SNR and THD
- Wide dynamic range and high linearity across operating conditions
- Integrated voltage reference with low temperature drift
- Flexible digital interface — SPI, I2C, or parallel options
- Industrial/automotive temperature range with guaranteed specs
- Low power consumption with power-down modes
Key Specifications
| Resolution | bits |
| Channels | — |
| Sample Rate | kSPS |
| Interface | — |
| Supply Voltage | V |
| Operating Temp | °C |
| Package | — |
| INL | LSB |
| SNR | dB |
| THD | dB |
Applications
LTC5582IDD#TRPBF: An RMS Detector From 40 MHz to 10 GHz That Does Not Care About Crest Factor
The LTC5582IDD#TRPBF is an RMS responding RF power detector covering 40 MHz to 10 GHz, with a linear dynamic range quoted up to 57 dB and an input span from -60 dBm to +2 dBm depending on frequency. Because it responds to true RMS, the reading is independent of the crest factor of the waveform, which is what makes it usable on LTE, W-CDMA and other modulated signals where a diode detector reads low. Accuracy over temperature is plus or minus 0.5 dB typical, rise time is 90 ns, supply current is 41.6 mA at 3.3 V, the output is a buffered DC voltage that drives a high capacitance load, the package is a 10-lead 3 mm by 3 mm DFN, the part is AEC-Q100 qualified, and it is pin to pin compatible with the LT5570.
The distinction between RMS and envelope detection is the whole purchase decision. A peak detector answers the question of how high the waveform goes; an RMS detector answers how much power it carries. On a constant envelope signal the two agree, and on a modulated signal with a high crest factor they do not.
57 dB of dynamic range and a 62 dB input span are two different numbers
The vendor headline is 57 dB of linear dynamic range, and the input span is -60 dBm to +2 dBm, which is 62 dB. The difference is the part of the span where the transfer function is guaranteed linear rather than merely monotonic, and a system that needs accuracy at the bottom of the range has to use the 57 dB figure. Quoting 62 dB as usable range is the mistake this arithmetic prevents.
An accuracy of plus or minus 0.5 dB is a power ratio of 1.122, or 12.2 percent, which at the top of the range is fine and at a -60 dBm input is a very small absolute error. In a power control loop the 0.5 dB becomes the loop's dead band, and a system that tries to regulate tighter than that will hunt.
90 ns rise is about 3.9 MHz of envelope bandwidth
A rise time of 90 ns corresponds to a single pole corner near 3.9 MHz, using the usual 0.35 divided by rise time relation. That is fast enough to follow a burst envelope and slow enough that the output is a clean DC for a converter to read. The buffered output drives a capacitive load, which is what allows a long trace to the ADC without the detector curve moving with the trace capacitance.
Supply current of 41.6 mA at 3.3 V is 137 mW, and over a year it is 364 Ah, so this detector is not a battery part. It belongs in a base station, a point to point link or an instrument, where the 41.6 mA is a small share of the total. The 10 GHz top of the range covers X band and the lower millimetre wave bands through an external coupler.
| Function | True RMS responding RF power detector |
| Frequency | 40 MHz to 10 GHz |
| Dynamic range | 57 dB guaranteed linear, input span -60 dBm to +2 dBm, 62 dB |
| Accuracy | Plus or minus 0.5 dB typical over temperature, a 1.122 power ratio |
| Response | 90 ns rise time, about 3.9 MHz of envelope bandwidth |
| Supply | 3.3 V at 41.6 mA, 137 mW |
| Output | Buffered DC voltage, drives a high capacitance load |
| Input | Single ended or differential RF |
| Compatibility | Pin to pin with the LT5570 |
| Package and grade | 10-lead 3 mm by 3 mm DFN, AEC-Q100 |
Two questions buyers ask
Why does crest factor matter for a power measurement?
Because a diode detector responds to the peak of the waveform and an RMS detector responds to the heating equivalent. A signal with a 10 dB crest factor has peaks ten times the average power, and a peak detector calibrated on a sine wave reads high by that factor. In a control loop that error turns into a transmit power that is wrong by the crest factor of the modulation.
Can it be used below 40 MHz?
No, the specified range starts at 40 MHz, and the internal matching sets the low end. A lower frequency measurement belongs on a logarithmic detector or a different part in the same family, and the pin compatibility with the LT5570 is the place to check for an alternative that covers a lower band.
Ordering and supply
The IDD suffix is the 10-lead 3 mm by 3 mm DFN body on the industrial grade, and TRPBF is tape and reel, lead free. The family carries six part models, and the pin compatibility with the LT5570 means a board can move between the two detectors without a new board pattern. The AEC-Q100 qualification is worth confirming on the exact code for an automotive build.
We supply this family for production and for repair. Start at the analog mixed signal ICs family page, compare a candidate against the pin to pin cross reference, and where a detector has to go into a radio that is already qualified, the sequence in how to verify a drop in replacement puts the response time and the output slope ahead of the pin check.
Request Quote — In Stock, 100% New & Original, Full Warranty